HomeMy WebLinkAbout726 Campfire Dr - Disclosures/Blower Door Test - 04/22/2015BUILDING LEAKAGE TEST Date of Test: 04/22/15 Customer: Myrtle Tree Contracting Test File: 726 Campfire Dr -Multi Point Tectite Technician: Justin Heldenbrand Project Number: EnergyLogic (35349) Building Address: 726 Campfire Dr Fort Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: 1457 CFM50 (+/- 0.3 %) (50 Pa = 0.2 w.c.) 2.91 ACH50 2. Leakage Area: 80.1 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 95.7 (+/- 7.6 %) Exponent (n) = 0.696 ( +/- 0.019 ) Correlation Coefficient = 0.99962 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 96.0 CFM 0.19 ACH 24.0 CFM per person Winter: 159.8 CFM Summer: 100.3 CFM 0.32 ACH 0.20 ACH Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 61.7 CFM Base Rate: 61.7 CFM BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 04/22/15 Test File: 726 Campfire Dr -Multi Point Tectite Building Information Location Climate Information Volume 29993 Surface Area 6642 Floor Area 3174 Height 30 # of Bedrooms 3 # of Occupants 4 Year of Construction 2015 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 275-7 10/31/2014 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 04/22/15 Test File: 726 Campfire Dr -Multi Point Tectite Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (OF) Altitude (ft) 60.0 55.0 5003.0 Data Points Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -0.6 n/a n/a -67.6 -67.0 95.2 1753 1785 -0.0 Ring A -64.5 -63.8 89.2 1698 1729 0.1 Ring A -61.3 -60.6 83.2 1641 1671 0.3 Ring A -57.4 -56.7 74.3 1553 1581 -0.6 Ring A -54.5 -53.8 70.0 1508 1536 0.2 Ring A -50.3 -49.6 61.7 1419 1445 -0.3 Ring A -47.4 -46.7 56.9 1364 1389 -0.0 Ring A 44.7 -44.0 52.6 1312 1336 0.3 Ring A -0.8 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET Multi -Point Test - Test Parameters (done BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 04/22/15 Test File: 726 Campfire Dr -Multi Point Tectite Comments Connection to: Mechanicals -50pa Garage -46.1 pa