HomeMy WebLinkAbout2053 Scarecrow Rd - Disclosures/Blower Door Test - 04/14/2015BUILDING LEAKAGE TEST
(� a GS Service
G S �S6ry es 2000 S College Ave.
- - Suite 308
Fort Collins, CO 80525
7l �
. � �
Date of Test: 4/14/2015 Test File: Bellisimo Construction - 2053 Scarecrow - Unit C - BDma
Customer: Bellisimo Technician: Paul Higman
Project Number: Unit C
Fort Collins, CO 80526
Building Address: 2053 Scarecrow
Fort Collins, CO 80525
Test Results
1. Airflow at 50 Pascals: 1305 CFM50 (+/-1.5 %)
(50 Pa = 0.2 w.c.) 4.77ACH50
2. Leakage Area: 71.8 in2 LBL ELA @ 4 Pa
3. Building Leakage Curve: Flow Coefficient (C) = 110.5 (+/- 11.0 %) f
Exponent (n) = 0.631 ( +/- 0.030 ) �Ik
Correlation Coefficient = 0.99885
4. Test Settings: Test Standard: RESNET Multi -Point Test
Test Mode: Depressurization
5. Accuracy Level Standard Level of Accuracy Test
Infiltration Estimates
1. Estimated Average Annual Infiltration Rate: 73.8 CFM
0.27 ACH
2. Estimated Design Infiltration Rate: Winter: 118.9 CFM Summer: 78.9 CFM
0.43 ACH 0.29 ACH
Cost Estimates
1. Estimated Cost of Air Leakage for Heating:
2. Estimated Cost of Air Leakage for Cooling:
Digitally signed by: Paul
Paul Higman
,.cilus -Paul Higman
Higman
Date. 2015.04.17 11:38:
Oe-06'00'