Loading...
HomeMy WebLinkAbout2053 Scarecrow Rd - Disclosures/Blower Door Test - 04/14/2015BUILDING LEAKAGE TEST (� a GS Service G S �S6ry es 2000 S College Ave. - - Suite 308 Fort Collins, CO 80525 7l � . � � Date of Test: 4/14/2015 Test File: Bellisimo Construction - 2053 Scarecrow - Unit C - BDma Customer: Bellisimo Technician: Paul Higman Project Number: Unit C Fort Collins, CO 80526 Building Address: 2053 Scarecrow Fort Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: 1305 CFM50 (+/-1.5 %) (50 Pa = 0.2 w.c.) 4.77ACH50 2. Leakage Area: 71.8 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 110.5 (+/- 11.0 %) f Exponent (n) = 0.631 ( +/- 0.030 ) �Ik Correlation Coefficient = 0.99885 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 73.8 CFM 0.27 ACH 2. Estimated Design Infiltration Rate: Winter: 118.9 CFM Summer: 78.9 CFM 0.43 ACH 0.29 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Digitally signed by: Paul Paul Higman ,.cilus -Paul Higman Higman Date. 2015.04.17 11:38: Oe-06'00'