Loading...
HomeMy WebLinkAbout4608 Chokecherry Trl - Disclosures/Blower Door Test - 03/31/20154, ,A 4 e BUILDING LEAKAGE TEST GS Services Ltd 2000 South College Ave #308 Fort Collins, Co 80525 Date of Test: 3/31/2015 Test File: PMD - 4608 Chockcherry Unit 2 - BDma Customer: PMD Technician: Paul Higman Project Number: Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: 5. Accuracy Level Building Address: 4608 Chockcherry Unit 2 Fort Collins, CO 80525 1177 CFM50 (+/-1.3 %) 2.97 ACH50 64.7 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 11.2 (+/- 9.9 %) Exponent (n) = 1.189 ( +/- 0.027 ) Correlation Coefficient = 0.99967 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 68.6 CFM 0.17 ACH 2. Estimated Design Infiltration Rate: Winter: 129.1 CFM Summer: 81.0 CFM 0.33 ACH 0.20 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Digitally signed by: Paul Paul Higman DN:1CN = Paul Higman C Higman /Date: 2015.04.0609:42:39 46,00. GS Sbmces f- - BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 3/31/2015 Test File: PMD - 4608 Chockcherry Unit 2 - BDma Building Information Volume 23810 Surface Area Floor Area 2381 Height 20 # of Bedrooms 3 # of Occupants Year of Construction 2014 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 19028-7 GS Sbm,ces s BUILDING LEAKAGE TEST Page 3 of 4 Date of.Test: 3/31/2015 Test File: PMD - 4608 Chockcherry Unit 2 - BDma Depressurization Test: Environmental Data Indoor Temperature (A°F) Outdoor Temperature (A°F) Altitude (ft) 67.0 64.0 5000.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -1.1 n/a n/a -60.1 -59.0 49.9 -55.5 -54.4 40.1 -50.1 -49.0 33.1 -45.7 -44.6 25.8 -39.4 -38.3 170.9 -35.2 -34.1 124.3 -29.9 -28.8 81.8 -24.9 -23.8 54.3 -20.4 -19.3 32.4 -1.2 n/a n/a Time Averaging Period: 10 1279 1425 -0.4 Ring A 1150 1281 -1.4 Ring A 1048 1168 1.8 Ring A 928 1034 0.8 Ring A 775 864 0.9 Ring B 662 738 -1.0 Ring B 538 600 -1.6 Ring B 439 489 0.8 Ring B 340 379 0.2 Ring B Deviations from Standard RESNET Multi -Point Test - Test Parameters None - * n value outside of normally accepted limits. * n value and/or correlation coefficient limits are not officially part of the RESNET Multi -Point Test Standard. GS Services -- BUILDING LEAKAGE TEST Page 4 of 4 Date otTest: 3/31/2015 Test File: PMD - 4608 Chockcherry Unit 2 - BDma Comments House WRT Garage =-45.4pa