Loading...
HomeMy WebLinkAbout427 Osiander St - Disclosures/Blower Door Test - 03/23/2015BUILDING LEAKAGE TEST x Y xoes Date of Test: 3/23/2015 Customer: FR Development Fort Collins, CO 80521 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: 5. Accuracy Level GS Services Ltd 2000 South College Ave #308 Fort Collins, Co 80525 Test File: FIR Development 427 Osiander -Amsterdam -BD Technician: Paul Higman Project Number: Building Address: 427 Osiander Fort Collins, CO 80524 926 CFM50 (+/- 3.1 %) 2.32 ACH50 50.9 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 51.3 (+/- 28.2 %) Exponent (n) = 0.739 (+/- 0.076 ) Correlation Coefficient = 0.99341 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 54.0 CFM 0.14 ACH 2. Estimated Design Infiltration Rate: Winter: 101.5 CFM Summer: 63.7 CFM 0.25 ACH 0.16 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Paul Digitally signed Pau(Higman DIS:cN = Paul H i g m arilg an C= US ....,' Dade. 2015.03.2• Cif8I_V3C5 BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 3/23/2015 Test File: FR Development 427 Osiander -Amsterdam -BD Building Information Location Climate Information Volume 23919 Surface Area Floor Area 2754 Height 20 # of Bedrooms 3 # of Occupants Year of Construction 2014 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) I Default CS 5�s BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 3/23/2015 Test File: FR Development 427 Osiander -Amsterdam -BD Depressurization Test: Environmental Data Indoor Temperature (AOF) Outdoor Temperature (AOF) Altitude (ft) 67.0 64.0 5000.0 Data Points Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -7.4 n/a n/a -66.5 -60.9 31.1 1015 1053 -1.7 Ring A -61.1 -55.5 26.4 938 97 -2.7 Ring A -57.5 -51.9 253.2 942 976 2.6 Ring B -53.8 -48.2 206.7 852 883 -2.0 Ring B -47.5 -41.9 176.9 788 817 0.6 Ring B -40.8 -35.2 141.2 705 731 2.3 Ring B -38.6 -33.0 137.5 696 721 5.8 Ring B -34.0 -28.4 95.7 582 603 -1.1 Ring B -26.4 -20.8 57.3 451 467 -3.4 Ring B -3.8 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET Multi -Point Test - Test Parameters im GSs BUILDING LEAKAGE TEST Page 4 of 4 Date Tn CI f o+•'V/GVro3l�2015 Test File: FIR Development 427 Osiander -Amsterdam -BD I JL. Comments House WRT Garage =-47.Opa