Loading...
HomeMy WebLinkAbout4612 Chokecherry Trl - Disclosures/Blower Door Test - 03/17/2015 (2)11 Pl LJ o�,�7o I l ixxe TS'erv' BUILDING LEAKAGE TEST GS Services Ltd 2000 South College Ave #308 Fort Collins, Cc 80525 Date of Test: 3/17/2015 Test File: PMD - 4612 Chockcherry Unit 2 - BDma Customer: PMD Technician: Paul Higman Project Number: Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: Building Address: 4612 Chockcherry Unit 2 Fort Collins, CO 80525 1094 CFM50 (+/- 1.9 %) 2.76 ACH50 60.2 M2 LBL ELA @ 4 Pa Flow Coefficient (C) = 14.6 (+/- 14.2 %) Exponent (n) = 1.104 ( +/- 0.039 ) Correlation Coefficient = 0.99921 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 63.8 CFM 0.16 ACH 2. Estimated Design Infiltration Rate: Winter: 120.0 CFM Summer: 75.3 CFM 0.30 ACH 0.19 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Digitally signed by: Paul Paul Higman ,DN:"M = Paul Higman Higman -:6?Ds Date. 2015.03.23 07:05: �'17-06'00' GS Ser�rices BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 3/17/2015 Test File: PMD - 4612 Chockcherry Unit 2 - BDma Building Information Volume 23810 Surface Area Floor Area 2381 Height 20 # of Bedrooms 3 # of Occupants Year of Construction 2014 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 1 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 19028-7 GS Sentices =--- BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 3/17/2015 Test File: PMD - 4612 Chockcherry Unit 2 - BDma Depressurization Test: Environmental Data Indoor Temperature (A°F) Outdoor Temperature (A°F) Altitude (ft) 67.0 36.0 5000.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -1.1 n/a n/a -59.8 -58.6 53.8 -55.5 -54.4 43.6 -49.7 -48.6 36.3 -44.7 -43.6 28.6 -38.7 -37.6 192.9 -34.9 -33.8 143.2 -29.6 -28.5 97.2 -25.0 -23.9 66.9 -20.1 -19.0 42.3 -1.2 n/a n/a Time Averaging Period: 10 1327 1303 -0.1 Ring A 1198 1177 -1.9 Ring A 1096 1077 1.6 Ring A 976 959 2.1 Ring A 823 808 1.4 Ring B 710 697 -1.6 Ring B 586 576 -2.0 Ring B 487 478 -1.0 Ring B 388 381 1.7 Ring B Deviations from Standard RESNET Multi -Point Test - Test Parameters None * n value outside of normally accepted limits. * n value and/or correlation coefficient limits are not officially part of the RESNET Multi -Point Test Standard. - GS SerYiGes BUILDING LEAKAGE TEST Page 4 of 4 =- Date of Test: 3/17/2015 Test File: PMD - 4612 Chockcherry Unit 2 - BDma Comments House WRT Garage =-47.4pa