Loading...
HomeMy WebLinkAbout4612 Chokecherry Trl - Disclosures/Blower Door Test - 03/17/2015Date of Test: 3/17/2015 Customer: Post Modern Development Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: BUILDING LEAKAGE TEST GS Services 2000 South College Ave #308 Fort Collins, Cc 80525 Test File: PMD - 4612 Chockcherry Unit 1 - BDma Technician: Paul Higman Project Number: Building Address: 4612 Chockcherry Unit 1 Fort Collins, CO 80525 1181 CFM50 (+/- 1.5 %) 2.98 ACH50 65.0 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 30.0 (+/- 13.1 %) Exponent (n) = 0.939 ( +/- 0.036 ) Correlation Coefficient = 0.99909 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 68.9 CFM 0.17ACH Winter: 129.5 CFM Summer: 81.3 CFM 0.33 ACH 0.20 ACH PaUI Digitally signed by: Paul Higman DN:,CN = Paul Higman Higman C = US Date: 2015.03.23 07: 13:35-06'00' e3 BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 3/17/2015 Test File: PMD - 4612 Chockcherry Unit 1 - BDma Building Information Volume 23810 Surface Area Floor Area 2381 Height 20 # of Bedrooms 3 # of Occupants Year of Construction 2014 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 19028-7 GS IS", qes M• BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 3/17/2015 Test File: PMD - 4612 Chockcherry Unit 1 - BDma Depressurization Test: Environmental Data Indoor Temperature (A°F) Outdoor Temperature (A°F) Altitude (ft) 70.0 36.0 5000.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -2.1 n/a n/a -61.0 -58.8 62.3 1426 1392 1.3 Ring A -57.0 -54.8 52.4 1310 1279 -0.6 Ring A -52.4 -50.1 43.0 1190 1162 -1.9 Ring A -47.0 -44.8 36.3 1096 1070 0.5 Ring A -42.6 -40.4 29.9 996 972 0.7 Ring A -38.7 -36.5 227.0 892 871 -0.8 Ring B -32.6 -30.4 163.9 759 741 0.3 Ring B -28.1 -25.9 125.9 666 650 2.3 Ring B -23.9 -21.6 83.0 542 529 -1.7 Ring B -2.4 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi -Point Test - Test Parameters None GS S p ges BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 3/17/2015 Test File: PMD - 4612 Chockcherry Unit 1 - BDma Comments House WRT Garage =-46.9pa