HomeMy WebLinkAbout421 Osiander St - Disclosures/Final Energy - 03/12/2015�1=012 �ECC Fear � Cosy Cramp"HaInce
Property Organization GS"Services
FR Development GS Services '
421 Osiander (970) 449-1612
Fort Collins, CO 80524 Paul Higman
Weather:Ft. Collins, CO Builder
421 Osiander FR Development
FR Development - 421 Osiander00 2
�1
Annual Energy Cost $/yr
2012 IECC As Designed
Heating 432 433
Cooling 131 114
Water Heating 115 115
SubTotal - Used to Determine Compliance 678 662
Lights £t Appliances 786 784
Photovoltaics -0 -0
Service Charge 240 240
Total 1705 1686
Mandatory Requirements
Duct Insulation R-Value Check (per Section 405.2)
Minimum Duct Insulation (Design must be equal or higher) 6.0 8.0
Window U-Factor Check (Section 402.5)
Window U-Factor (Design must be equal or lower) 0.480 0.348
HomeInfiltration (Section 402.4.1.2) PASSES
Duct Leakage (Section 403.2.2) PASSES
Mechanical Ventilation (Section403.5) PASSES
'This home MEETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code
based on a climate zone of 5B. In fact, this home surpasses the requirements by 2.4%. Paul Digitally signed
by: Paul Higman
DN: CN = Paul
Name Paul Higman Signature H ig m anHigman C = US
Organization GS Services Date 12 March 2015 a 21 195.0 .1
Mechanical Systems
Heating
Cooling
Water Heating
Window -to -Floor Area Ratio:
Blower door test
Fuel -fired air distribution, 44.0 kBtuh, 92.1 AFUE.
Air conditioner, 24.0 kBtuh, 13.0 SEER.
Conventional, Gas, 0.62 EF.
0.10
Htg: 1302 Clg: 1302 CFM50
REtA/Design - I:esidential Energy Analysis Software v'4.5.1
This information does not constitute any warranty of energy cost or savings.
0 1985-2014 Architectural Energy Corporation, Boulder, Colorado.
2012 IECC Energy Cost Compliance
G S §pb Vices
Property Organization ""
FR Development GS Services
421 Osiander (970) 449-1612
Fort Collins, CO 80524 Paul Higman
Weather.Ft. Collins, CO Builder Nr ec Opp
421 Osiander FR Development
P
FR Development - 421 Osiander L
In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to
calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the
design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained
periodically to ensure the compliance calculations reflect current federal minimum standards.
REWDesign - Residential Energy Analysis Software v14.5.1
This information does not constitute any warranty of energy cost or savings.
0 1985-2014 Architectural Energy Corporation, Boulder, Colorado. Page 2 of 2
City of
Flirt Collins
Planning, Development & Transportation Services
Community Development & Neighborhood Services
Simulated Performance Alternative (SPA) Cover Sheet See Residential New Construction
SPA Guide
1. Submittal and Rating Type
❑ Stock Plan Permit — Projected Worst -Case Rating
❑ Lot -specific Permit - Projected Rating
❑ Completed Home — Confirmed Rating
2. Data Required for All SPA Ratings
Builder: FR Development
Energy Rater: Paul Higman
Builde od' : el - on
Address: 421 Osiander
Rating Firm:
GS Services
3-11-15
Date:
Duct Location Inputs (REM/Rate "Duct Systems" page)
Duct Location
Supply
Return
% Area
I R-Value
% Area
R-Value
All within Conditioned space
100
r-0
100
r-0
Thermal Envelope
Clarification
Component
Thermal Location
Crawl space
® N/A
❑ Inside
❑ Outside
Attic
❑ N/A
❑ Inside
® Outside
Bonus room
® N/A
❑ Inside
❑ Outside
Ductwork adjacent to garage
® NIA
❑ Inside
❑ Outside
Other:
❑ N/A
❑ Inside
❑ Outside
UtilitV Rates
Energy
Service
Variable
Source
Charge
Rate
Electricity
5 $/mo
m $/kWh
Natural
15 $/mo
0.6 $/therm
as
3A. Additional Information for Stock Plan Permit — Projected Worst -Case Rating
Worst -Case Configuration I
elevation
Options
included
❑ Attach REM/Rate 2012 IECC Energy Cost Compliance report showing "PASS"
❑ Attach REM/Rate Energy Code Inspection Checklist
3B. Additional Information for Lot -Specific Permit — Projected Rating
❑ Attach REM/Rate 2012 IECC Energy Cost Compliance report showing "PASS"
❑ Attach R EM/Rate Energy Code Inspection Checklist
3C. Additional Information for Completed Home — Confirmed Rating
❑ Attach REM/Rate 2012 IECC Energy Cost Compliance report showing "PASS"
(Utility rates reflected in this report must be City -approved rates on lot -specific permit application date.)
0 Attach REM/Rate Home Energy Rating Certificate