Loading...
HomeMy WebLinkAbout421 Osiander St - Disclosures/Final Energy - 03/12/2015�1=012 �ECC Fear � Cosy Cramp"HaInce Property Organization GS"Services FR Development GS Services ' 421 Osiander (970) 449-1612 Fort Collins, CO 80524 Paul Higman Weather:Ft. Collins, CO Builder 421 Osiander FR Development FR Development - 421 Osiander00 2 �1 Annual Energy Cost $/yr 2012 IECC As Designed Heating 432 433 Cooling 131 114 Water Heating 115 115 SubTotal - Used to Determine Compliance 678 662 Lights £t Appliances 786 784 Photovoltaics -0 -0 Service Charge 240 240 Total 1705 1686 Mandatory Requirements Duct Insulation R-Value Check (per Section 405.2) Minimum Duct Insulation (Design must be equal or higher) 6.0 8.0 Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower) 0.480 0.348 HomeInfiltration (Section 402.4.1.2) PASSES Duct Leakage (Section 403.2.2) PASSES Mechanical Ventilation (Section403.5) PASSES 'This home MEETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code based on a climate zone of 5B. In fact, this home surpasses the requirements by 2.4%. Paul Digitally signed by: Paul Higman DN: CN = Paul Name Paul Higman Signature H ig m anHigman C = US Organization GS Services Date 12 March 2015 a 21 195.0 .1 Mechanical Systems Heating Cooling Water Heating Window -to -Floor Area Ratio: Blower door test Fuel -fired air distribution, 44.0 kBtuh, 92.1 AFUE. Air conditioner, 24.0 kBtuh, 13.0 SEER. Conventional, Gas, 0.62 EF. 0.10 Htg: 1302 Clg: 1302 CFM50 REtA/Design - I:esidential Energy Analysis Software v'4.5.1 This information does not constitute any warranty of energy cost or savings. 0 1985-2014 Architectural Energy Corporation, Boulder, Colorado. 2012 IECC Energy Cost Compliance G S §pb Vices Property Organization "" FR Development GS Services 421 Osiander (970) 449-1612 Fort Collins, CO 80524 Paul Higman Weather.Ft. Collins, CO Builder Nr ec Opp 421 Osiander FR Development P FR Development - 421 Osiander L In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REWDesign - Residential Energy Analysis Software v14.5.1 This information does not constitute any warranty of energy cost or savings. 0 1985-2014 Architectural Energy Corporation, Boulder, Colorado. Page 2 of 2 City of Flirt Collins Planning, Development & Transportation Services Community Development & Neighborhood Services Simulated Performance Alternative (SPA) Cover Sheet See Residential New Construction SPA Guide 1. Submittal and Rating Type ❑ Stock Plan Permit — Projected Worst -Case Rating ❑ Lot -specific Permit - Projected Rating ❑ Completed Home — Confirmed Rating 2. Data Required for All SPA Ratings Builder: FR Development Energy Rater: Paul Higman Builde od' : el - on Address: 421 Osiander Rating Firm: GS Services 3-11-15 Date: Duct Location Inputs (REM/Rate "Duct Systems" page) Duct Location Supply Return % Area I R-Value % Area R-Value All within Conditioned space 100 r-0 100 r-0 Thermal Envelope Clarification Component Thermal Location Crawl space ® N/A ❑ Inside ❑ Outside Attic ❑ N/A ❑ Inside ® Outside Bonus room ® N/A ❑ Inside ❑ Outside Ductwork adjacent to garage ® NIA ❑ Inside ❑ Outside Other: ❑ N/A ❑ Inside ❑ Outside UtilitV Rates Energy Service Variable Source Charge Rate Electricity 5 $/mo m $/kWh Natural 15 $/mo 0.6 $/therm as 3A. Additional Information for Stock Plan Permit — Projected Worst -Case Rating Worst -Case Configuration I elevation Options included ❑ Attach REM/Rate 2012 IECC Energy Cost Compliance report showing "PASS" ❑ Attach REM/Rate Energy Code Inspection Checklist 3B. Additional Information for Lot -Specific Permit — Projected Rating ❑ Attach REM/Rate 2012 IECC Energy Cost Compliance report showing "PASS" ❑ Attach R EM/Rate Energy Code Inspection Checklist 3C. Additional Information for Completed Home — Confirmed Rating ❑ Attach REM/Rate 2012 IECC Energy Cost Compliance report showing "PASS" (Utility rates reflected in this report must be City -approved rates on lot -specific permit application date.) 0 Attach REM/Rate Home Energy Rating Certificate