HomeMy WebLinkAbout421 Osiander St - Disclosures/Blower Door Test - 03/11/2015BUILDING LEAKAGE TEST
Gib"!{x_
Date of Test: 3/11 /2015
Customer: FIR Development
Fort Collins, CO 80525
Test Results
1. Airflow at 50 Pascals:
(50 Pa = 0.2 w.c.)
2. Leakage Area:
3. Building Leakage Curve:
4. Test Settings:
5. Accuracy Level
Infiltration Estimates
GS Services Ltd
2000 S College Ave. #308
Ste 308
Fort Collins, CO 80525
Test File: FIR De
Technician:
Project Number:
Building Address
1302 CFM50 (+/- 0.4 %)
2.49 ACH50
71.6 in2 LBL ELA @ 4 Pa
�����ti7 ruu�aovnmuh��
Munich
421 Osiander
Fort Collins, CO 80525
Flow Coefficient (C) = 107.0 (+/- 3.0 %)
Exponent (n) = 0.639 ( +/- 0.008 )
Correlation Coefficient = 0.99992
Test Standard: RESNET Multi -Point Test
Test Mode: Depressurization
Standard Level of Accuracy Test
1. Estimated Average Annual Infiltration Rate:
2. Estimated Design Infiltration Rate:
Cost Estimates
1. Estimated Cost of Air Leakage for Heating:
2. Estimated Cost of Air Leakage for Cooling:
u I Digitally signed by: P
Higinan
DN:,CN = Paul Higm.
Higman -Ds
Date: 2015.03.12 08:
29-06'00'
G�ViCG'S BUILDING LEAKAGE TEST Page 2 of 4
Date of Test: 3/11/2015 Test File: FR Development - 421 Osiander-
Building Information
Volume
31361
Surface Area
Floor Area
2896
Height
# of Bedrooms
# of Occupants
Year of Construction
2014
Wind Shield
M
Heating and Cooling Cost and Efficiency Information
Heating Fuel Gas
Heating Fuel Cost
Heating Efficiency %
Cooling Fuel Cost
Cooling SEER
Location Climate Information
Ventilation Weather Factor
0.87
Energy Climate Factor
17.00
Heating Degree Days
6128
Cooling Degree Days
297
Design Winter Wind Speed
7.3 mph
Design Summer Wind Speed
9.4 mph
Design Winter Temp Diff
73 deg F
Design Summer Temp Diff
15 deg F
Equipment Information
Type
Manufacturer
Model
Serial Number
Custom Calibration Date
Fan
Energy Conservatory
Model 3 (110V)
Default
Micromanometer
Energy Conservatory
DG700
19028-7
9/9/2014
G5 SB1£'3 BUILDING LEAKAGE TEST Page 3 of 4/7
Date of Test: 3/11/2015 Test File: FR Development - 421 Osiander- M pich B Cc} t
Depressurization Test:
Environmental Data
Indoor Temperature (%°F) Outdoor Temperature (AOF) Altitude (ft)
I 65.0 1 39.0 5000.0
Data Points
Nominal Baseline Adjusted Fan Nominal Adjusted
Building Pressure Building Pressure Pressure Flow Flow Fan
(Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration
-2.4
n/a
n/a
-62.0
-59.9
68.8
-56.4
-54.3
59.9
-50.7
-48.6
51.7
-44.2
-42.1
42.8
-38.7
-36.6
35.9
-32.7
-30.6
28.2
-26.3
-24.2
202.2
-17.5
-15.4
110.6
-1.8
n/a
n/a
Time Averaging Period: 0
1495
1465
0.3
Ring A
1399
1371
-0.1
Ring A
1301
1275
-0.3
Ring A
1187
1163
-0.3
Ring A
1090
1068
0.2
Ring A
969
949
-0.2
Ring A
842
825
0.8
Ring B
624
612
-0.4
Ring B
Deviations from Standard RESNET Multi -Point Test - Test Parameters
GS S2SZ1G8 BUILDING LEAKAGE TEST Page 4 of 4
Cate of Test: 3/11/2015 Test File: FIR Development - 421 Osiander- Munich - BD1
Comments..-
" a4u
House WRT Garage =-45.9pa