HomeMy WebLinkAbout421 Osiander St - Disclosures/Blower Door Test - 03/11/2015BUILDING LEAKAGE TEST Gib"!{x_ Date of Test: 3/11 /2015 Customer: FIR Development Fort Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: 5. Accuracy Level Infiltration Estimates GS Services Ltd 2000 S College Ave. #308 Ste 308 Fort Collins, CO 80525 Test File: FIR De Technician: Project Number: Building Address 1302 CFM50 (+/- 0.4 %) 2.49 ACH50 71.6 in2 LBL ELA @ 4 Pa �����ti7 ruu�aovnmuh�� Munich 421 Osiander Fort Collins, CO 80525 Flow Coefficient (C) = 107.0 (+/- 3.0 %) Exponent (n) = 0.639 ( +/- 0.008 ) Correlation Coefficient = 0.99992 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: u I Digitally signed by: P Higinan DN:,CN = Paul Higm. Higman -Ds Date: 2015.03.12 08: 29-06'00' G�ViCG'S BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 3/11/2015 Test File: FR Development - 421 Osiander- Building Information Volume 31361 Surface Area Floor Area 2896 Height # of Bedrooms # of Occupants Year of Construction 2014 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 19028-7 9/9/2014 G5 SB1£'3 BUILDING LEAKAGE TEST Page 3 of 4/7 Date of Test: 3/11/2015 Test File: FR Development - 421 Osiander- M pich B Cc} t Depressurization Test: Environmental Data Indoor Temperature (%°F) Outdoor Temperature (AOF) Altitude (ft) I 65.0 1 39.0 5000.0 Data Points Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -2.4 n/a n/a -62.0 -59.9 68.8 -56.4 -54.3 59.9 -50.7 -48.6 51.7 -44.2 -42.1 42.8 -38.7 -36.6 35.9 -32.7 -30.6 28.2 -26.3 -24.2 202.2 -17.5 -15.4 110.6 -1.8 n/a n/a Time Averaging Period: 0 1495 1465 0.3 Ring A 1399 1371 -0.1 Ring A 1301 1275 -0.3 Ring A 1187 1163 -0.3 Ring A 1090 1068 0.2 Ring A 969 949 -0.2 Ring A 842 825 0.8 Ring B 624 612 -0.4 Ring B Deviations from Standard RESNET Multi -Point Test - Test Parameters GS S2SZ1G8 BUILDING LEAKAGE TEST Page 4 of 4 Cate of Test: 3/11/2015 Test File: FIR Development - 421 Osiander- Munich - BD1 Comments..- " a4u House WRT Garage =-45.9pa 2012 IECC Target is < 1568 �4 "