Loading...
HomeMy WebLinkAbout2426 Marshfield Ln - Disclosures/Blower Door Test - 10/11/2014erv'm BUILDING LEAKAGE TEST GS Services 2000 S. College Ave Suite 308 Fort Collins, CO 80525 Date of Test: 10/11/2014 Test File: Journey Homes - 2426 Marshfield Ln- R1540 - BD Customer: Journey Homes Technician: Paul Higman Project Number: R1540 Greeley, CO 80634 Building Address: 2426 Marshfield Ln Fort Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: 5. Accuracy Level Infiltration Estimates 1386 CFM50 (+/- 2.0 %) 2.89 ACH50 76.2 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 134.8 ( +/-14.4 %) Exponent (n) = 0.596 ( +/- 0.040) Correlation Coefficient = 0.99775 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test 1. Estimated Average Annual Infiltration Rate: 65.7 CFM 0.14 ACH. 2. Estimated Design Infiltration Rate: Winter: 92.9 CFM Summer: 68.2 CFM 0.19 ACH 0.14 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Paul Digitally signed by: Paul Hagman DN 'CN = Paul Higman Higman,�`/,""'us Day e: 2014.10.22 10:39: 158-06'00' < GS s4vices BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 10/11/2014 Test File: Journey Homes - 2426 Marshfield Ln- R1540 - BD Building Information Volume 28744 Surface Area FloorArea 3134 Height 10 # of Bedrooms 3 # of Occupants Year of Construction 2014 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 t A a � • A°: ��' s' GS�.�e���S gU1LDING LEAKAGE TEST Page 3 of 4 Date of Test: 10l11/2014 Test File: Journey Homes-2426 Marshfield Ln-R1540- BD Depressurization Test: Environmental Data Indoor Temperature(A°F) Outdoor Temperature(A°F) Altitude(ft) 71.0 68.0 5000.0 Data Points-Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -1.2 n/a n/a -60.4 -59.6 69.6 1505 1527 -0.8 Ring A -55.2 -54.4 60.9 1410 1431 -1.8 Ring A -45.1 -44.3 52.3 1309 1328 3.0 Ring A -40.3 -39.5 43.8 1200 1217 1.1 Ring A -34.7 -33.9 36.0 1091 1107 0.7 Ring A -30.4 -29.6 29.4 988 1002 -1.2 Ring A -25.1 -24.3 220.4 879 892 -1.1 Ring B -20.1 -19.3 171.8 777 788 0.3 Ring B -0.4 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test-Test Parameters None & TM;�a.� GS S�e i��s gUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 10/11l2014 Test File: Journey Homes-2426 Marshfield Ln-R1540-BD Comments House WRT Garage=-47.3 pa