Loading...
HomeMy WebLinkAbout2408 Marshfield Ln - Disclosures/Final Energy - 10/22/2014stm. ��; � e �.. i....- , �., ♦i '' s. t�° �� P. _ - 'l�k d � E � l" q ry p A Property Organization' V*�� Journey Homes GS Services 2408 Marshfield Ln (970) 449-1612 Fort Collins, CO 80524 Paul Higman Weather:Ft. Collins, CO Builder 2408 Marshfield Ln Journey Homes Journey Homes 2408 Marshfield Annual Energy Cost $iyr 2012 IECC As Designed ;HeaCiyng, 397 ., 408 ;Cooling' 140 99 SubTotal - U Used to Determine Compliance 914 ' 884 { Lights It Appliances 725 ` 724 y Photovoltaics .0'° -0' Service Charge 240 240,1 'Total 1879 1849i Mandatory Requirements 'Window U-Factor Check (Section 402.5) WindowU-Factor(Design must be equal or lower) 0.480 0.3201, Home Infiltration (Section,402.4.1.2) PASSES Duct Leakage (Section 403.2.2) _ PASSES; Mechanical Ventilation (Section 403.5) PASSES] This home MEETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code based on a climate zone of 5B. In fact, this home surpasses the requirements by 3.2%. Digitally signed Paul by: paulHigman DN: CN = Paul man Si Higman C = US g g H i g m a nDare Name Paul Hi nature : 2014.10.22 Organization GS Services Date 22 October 2014 1-1:00:16-06'00' Mechanical Systems Heating Fuel -fired air distribution, 78.0 kBtuh, 95.0 AFUE. , Water Heating Conventional, Elec, 0.95EF. , Cooling Air conditioner,,15.2 kBtuh, 13.0 SEER. Window -to -Floor Area Ratio: 0.13 Blower door test Hfg: 1088 Clg 1088, CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Design - Residential Energy Analysis Software v14.4.1 This information does not constitute any warranty of energy cost or savings. © 1985-2014 Architectural Energy Corporation, Boulder, Colorado. City of port\,Collins Planning, Development & Transportation Services Community Development & Neighborhood Services Simulated Performance Alternative (SPA) Cover Sheet Submittal and Rating Type ❑Stock Plan Permit — Projected Worst -Case Rating Lot -specific Permit - Projected Rating ❑� Completed Home —Confirmed Rating Data Required for All SPA Ratings Builder: Journey Homes Energy rater: Paul Higman Builder Model: Address: Address: 2408 Marshfield Ln Rating Firm: GS Services Date: 10-21-14 Duct Location Inputs Location Su ply Return % Area R-Value % Area R-Value All within conditioned space 100 0 100 0 Utility Rates Energy Source I Service charge I Rate Electricity 5 $/month 0.10 $/kWh Natural gas 115 $/month 10.60 $/therm Spaces considered outside the thermal boundary: Additional Information for Stock Plan Permit — Projected Worst -Case Rating "Worst -case" configuration: Foundation type(s) Options included Orientation of front elevation eAttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report Attach REM/Rate Energy Code Inspection Checklist Additional Information for Lot -Specific Permit — Projected Rating I—f ttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report ttach REM/Rate Energy Code Inspection Checklist Additional Information for Completed Home — Confirmed Rating Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report (Utility rates reflected in this report must be City -approved rates on lot -specific permit application date.) Attach Home Energy Rating Certificate Updated 11/09/2012