Loading...
HomeMy WebLinkAbout2315 Forecastle Dr - Disclosures/Blower Door Test - 10/11/20144q.y GSIr�r` w BUILDING LEAKAGE TEST GS Services 2000 S. College Ave Suite 308 Fort Collins, CO 80525 I"! US 9. Date of Test: 10-11-14 Test File: Journey Homes 2315 Forecastle Dr-SL1888- BD Customer: Journey Homes Technician: Paul Higman Project Number: SL1888 Greeley, CO 80634 Building Address: 2315 Forecastle Dr Fort Collins, CO 80524 Test Results 1. Airflow at 50 Pascals: 977 CFM50 (+/- 0.5 %) (50 Pa = 0.2 w.c.) 2.61 ACH50 0.4047 CFM50/ft2 floor area 2. Leakage Areas: 114.5 in2 ( +/- 2.0 %) Canadian EgLA @ 10 Pa 65.6 in2 (+/- 3.3 %) LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 104.8 ( +/- 5.2 %) Exponent (n) = 0.571 ( +/- 0.014 ) Correlation Coefficient = 0.99795 4. Test Settings: Test Standard: CGSB Test Mode: Depressurization Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 65.0 CFM 0.17 ACH 2. Estimated Design Infiltration Rate: Winter: 110.7 CFM Summer: 62.1 CFM 0.30 ACH 0.17 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Digitally signed by: Paul Pauf Higman < DN,,CN = Paul Higman � aie:20 4.101512: .:5, :29-06'00' ; '-6 j Cif ► 2YV--BUILDING LEAKAGE TEST Page,.;2 o f4 f, .�.- Date of Test: 10-11-14 Test File: Journey Homes 2315 Forecastle Dr -SL 88-�D Building Information Location Climate Information Volume 22477 Surface Area Floor Area 2413 Height 16 # of Bedrooms 3 # of Occupants Year of Construction 2013 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6020 Cooling Degree Days 287 Design Winter Wind Speed 9.0 mph Design Summer Wind Speed 7.0 mph Design Winter Temp Diff 69 deg F Design Summer Temp Diff 16 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 er -ICes BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 10-11-14 Test File: Journey Homes 2315 Forecastle Dr-SL1888- BD Depressurization Test: Environmental Data Indoor Temperature (A°F) Outdoor Temperature (A°F) 64.0 72.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -1.7 n/a n/a -60.2 -58.6 34.9 1075 1083 1.4 Ring A -55.5 -53.9 31.0 1015 1023 0.4 Ring A -50.5 -48.9 26.8 945 952 -1.2 Ring A -45.6 -44.0 224.4 887 894 -1.5 Ring B -40.5 -38.9 202.0 842 848 0.3 Ring B -35.6 -34.0 166.5 765 771 -1.6 Ring B -30.1 -28.5 143.6 711 716 1.2 Ring B -25.6 -24.0 113.6 633 638 -0.6 Ring B -20.1 -18.5 88.4 559 563 1.9 Ring B -1.6 n/a n/a Deviations from Standard CGSB - Test Parameters None t 'r GS Ser. kes BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 10-11-14 Test File: Journev Homes 2315 Forecastle Dr-SL1888- BD House WRT Garage -47.3 pa