HomeMy WebLinkAbout408 E Elizabeth St - Special Inspections/Engineering - 08/21/2014D. M. FERRIN
4336 E. County Road 48
Fort Collins, Colorado 80524
970-493-9394
Date: Aug. 21, 2014
Site Solutions
Attn: Brian Stephenson
1025 N. Highway 287 — Suite #3
Fort Collins, CO 80524
Site Address: 406E. Elizabeth St.
Ft. Collins, CO.
P.E.#11585
Emergency escape and rescue window is reouired
for every basement and sleeping room The opening
must have a mi: .clear opening of 5.7 sq. ft., 24" min.
height and 20' min. moth Sill ht. of 44" max, above floor.
Escape window well shall have a horizontal min.
opening of 9 sq. ft, 8 a min, projection and width of 36'.
Well depths greater than 44" must be equipped with a
Permanent ladder or stairs.
ALL ELECTRICAL WORK SHALL
BE IN COMPLIANCE WITH THE
CURRENT N.E.C.
SMOKE & CO ALARMS
ARE REQUIRED PER
CURRENT- IRC / IBC
The above site was personally inspected on Aug. 20, 2014. The site indicates the existing
windows that are to be removed and replaced with approved 4'x4' "egress windows" are
located on the North side (3 each) of the house and 1 each on West (north) side. The sites
are located in a concrete foundation with asbestos siding above. The house has an
existing wood rim joist and sill plate and 2"x4" headers. There will be no disturbance to
these and/or the siding. With the new window frames and existing headers, support of
the siding should be adequate and is therefore approved for installation.
Sincerely,