Loading...
HomeMy WebLinkAbout5118 Daylight Ct - Disclosures/Blower Door Test - 10/26/2014f � 'R r ery - Date of Test: 10/26/2014 Customer: Houts Dev and Const Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: BUILDING LEAKAGE TEST GS Services 2000 South College Ave Suite 308 Fort Collins, CO 80525 Test File: Bogard Const 5118 Daylight Ct -BD Technician: Paul Higman Project Number: Building Address: 5118 Daylight Ct Fort Collins, CO 80528 1403 CFM50 (+/- 1.8 %) 2.29 ACH50 77.2 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 63:6 (+/- 15.3 %) Exponent (n) = 0.791 ( +/- 0.042 ) Correlation Coefficient = 0.99826 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 66.5 CFM 0.11 ACH 2. Estimated Design Infiltration Rate: Winter: 94.0 CFM Summer: 69.0 CFM 0.15ACH 0.11ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Paul Digitp,llysignedby: Paul ` Higman DN$:1CN = Paul Higman C = Higman Dale: 2014.10.2804:09:33 GS serxim BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 10/26/2014 Test File: Bogard Const 5118 Daylight Ct -BD Building Information Volume 36729 Surface Area Floor Area 3689 Height 10 # of Bedrooms 4 # of Occupants Year of Construction 2014 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer . Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 9876 Default Micromanometer Energy Conservatory DG700 dI •"r =a Ci8IY12S BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 10/26/2014 Test File: Bogard Consf 5118 Daylight Ct -BD Depressurization Test: Environmental Data Indoor Temperature (A°F) Outdoor Temperature (A°F) Altitude (ft) 70.0 1 74.0 5000.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Building Pressure Building Pressure Pressure (Pa) (Pa) (Pa) -0.2 n/a n/a -61.5 -61.0 71.0 -54.2 -53.7 60.6 -50.1 -49.6 54.1 -45.5 -45.0 45.3 -42.2 -41.7 37.2 -36.8 -36.3 30.2. -30.8 -30.3 227.0 -25.5 -24.9 169.6 -21.9 -21.3 125.1 -0.9 n/a n/a Time Averaging Period: 10 None Nominal Adjusted Flow Flow Fan (cfm) (cfm) % Error Configuration 1519 1620 -1.2 Ring A 1406 1500 1.1 Ring A 1331 1420 1.9 Ring A 1221 1303 1.0 Ring A 1109 1183 -2.6 Ring A 1002 1069 -1.7 RingA 892 952 0.9 Ring B 772 824 1.7 Ring B 664 708 -1.0 Ring B Deviations from Standard RESNET Multi -Point Test - Test Parameters