HomeMy WebLinkAbout2013 Scarecrow Rd - Disclosures/Blower Door Test - 01/26/2015G,S`Sbr-- Date of Test: 1/26/2015 Customer: Bellisimo Construction Inc Fort Collins, CO 80526 Test Results 1. Airflow at 50 Pascals (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: BUILDING LEAKAGE TEST GS Services Ltd 2000 S College Ave. Suite 308 Fort Collins, CO 80525 A 00 Test File: Bellisimo Construction - 2013 Scarecrow - UnitA - BD Technician: Phil Sietz Project Number: Unit A Building Address: 2013 Scarecrow Fort Collins, CO 80525 977 CFM50 (+/- 0.7 %) 3.53 ACH50 53.7 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 72.0 (+/- 4.9 %) Exponent (n) = 0.667 ( +/- 0.014 ) Correlation Coefficient = 0.99979 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 55.2 CFM 0.20 ACH 2. Estimated Design Infiltration Rate: Winter: 89.0 CFM Summer: 59.1 CFM 0.32 ACH 0.21 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 2FEB 15 4:37PM D -/�:-_ . Digitally signed Paul by: Paul Higman R-ICN = Paul Higman2gmanC=US e Dale: 2015.01.27 12:53:43-06'00' GS Services �,.-- -- BUILDING LEAKAGE TEST P4EPe k40u Date of Test: 1/26/2015 Test File: Bellisimo Construction - 2013 Scarecrow - Unit - BD Building Information Location Climate Information Volume j 16609 Surface Area Floor Area ! 1622 Height 18 # of Bedrooms 3 # of Occupants Year of Construction 2013 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel ! Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) I Default L �. f J GS Ser3tiGes -.- BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 1/26/2015 Test File: Bellisimo Construction - 2013 Scar 3ro nit' ALBOO Depressurization Test: Environmental Data Indoor Temperature (A°F) Outdoor Temperature (A°F) Altitude (ft) 70.0 1 66.0 5000.0 Data Points Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -1.1 n/a n/a -59.9 -58.7 33.9 1060 1086 -0.1 Ring A -54.7 -53.4 30.0 998 1023 0.2 Ring A -49.2 -48.0 244.4 925 948 -0.2 Ring B -43.6 -42.4 207.1 852 874 -0.2 Ring B -36.9 -35.7 164.6 761 780 -0.1 Ring B -31.0 -29.8 128.8 674 691 -0.1 Ring B -24.8 -23.6 97.0 585 600 1.2 Ring B -19.1 -17.8 63.8 476 488 -0.8 Ring B -1.4 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET Multi -Point Test - Test Parameters None GS Services , r.---- — BUILDING LEAKAGE TEST Pa�4 Date of Test: 1/26/2015 Test File: Bellisimo Construction - 2013 Scarecrow - Unit A - BD Comments House WRT Garage = 45.Opa Targets: 0.3ach50 = <830 cfm50 0.4ach50= <1107 cfm50