HomeMy WebLinkAbout550 San Juan Dr - Disclosures/Air Sealing - 07/12/2012BUILDING LEAKAGE TEST Thermal Concepts 6617 S. College ave Fort Collins, CO 80525 Phone: 970-223-7090 Date of Test: 7-12-12 Technician: Paul Higman Test File: Journey Homes 550 San Juan _1738 BD Customer: Journey Homes Building Address: 550 San Juan Dr Fort Collins, CO 80525 Greeley, CO 80634 Phone Test Results 1. Airflow at 50 Pascals: 1266 CFM (+/- 0.5 %) (50 Pa = 0.2 w.c.) 2.97 ACH 0.50 CFM per ft2 floor area 2. Leakage Areas: 118.8 in2 ( +/- 2.2 %) Canadian EgLA @ 10 Pa 59.9in2(+/-3.7%)LBLELA@4Pa 3. Minneapolis Leakage Ratio: 0.00 CFM50 per ft2 surface area 4. Building Leakage Curve: Flow Coefficient (C) = 79.0 ( +/- 6.0 %) Exponent (n) = 0.709 ( +/- 0.016 ) Correlation Coefficient = 0.99894 5. Test Settings: Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door, SIN 9876 Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 74.5 CFM 0.18 ACH 2. Estimated Design Infiltration Rate: Winter: 101.2 CFM 0.24 ACH Summer: 57.5 CFM 0.14 ACH 3. Recommended Whole Building Mechanical 43.6 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 7-12-12 Test File: Journey Homes 550 San Juan _1738 BD Building Conditions Inside Temperature: Outside Temperature: # of Stories Wind Shield: # of Occupants 85 deg F Heating Fuel: 87 deg F Heating Fuel Cost: 2.0 Heating Efficiency: Heating Degree Days: M Cooling Fuel Cost: Cooling SEER: Cooling Degree Days: # of Bedrooms: 3.0 Volume: 25536 ft3 Surface Area: Floor Area: 2544 ft2 Design Winter Wind Speed: 9.0 mph Design Summer Wind Speed: 7.0 mph Comments House wrt Garage =-47.8pa House wrt Mech room = Electric water heater Ventilation Weather Factor: Energy Climate Factor: Design Winter Temp Diff: Design Summer Temp Diff: Gas 6020 287 0.87 17.0 69 deg F 16 deg F BUILDING LEAKAGE TEST Page 3 Date of Test: 7-12-12 Test File: Journey Homes 550 San Juan _1738 BD Data Points: Data Entered Manually Nominal Temperature Building Fan Pressure Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Std Dev (Pa) -0.9 n/a +/- 0.00 -49.9 47.6 1250 1252 -0.0 Ring A -45.2 41.4 1168 1170 0.3 Ring A -40.1 33.7 1056 1058 -1.1 Ring A -35.4 29.1 984 986 0.8 Ring A -30.2 219.8 878 880 0.9 Ring B -25.1 161.7 754 755 -0.9 Ring B -0.4 n/a +/- 0.00