Loading...
HomeMy WebLinkAbout2933 Joseph Dr - Disclosures/Blower Door Test - 09/23/2014BUILDING LEAKAGE TEST Date of Test: 9/23/2014 Test File: Savant Blower Door Customer: Savant PO Box 2066 Fort Collins, CO 80522 Phone 970-472-5667 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas 3. Minneapolis Leakage Ratio: 4. Building Leakage Curve: 5. Test Settings: Infiltration Estimates Technician: Doug Groff Building Address: 2933 Joseph Dr. Fort Collins, Colorado 80525 1031 CFM (+/- 0.1 %) 2.53 ACH 0.52 CFM per ft2 floor area 236.6 in2 (+/ 0.7 %) Canadian EgLA @ 10 Pa 198.3 in2 (+/ 1.1 %) LBL ELA @ 4 Pa 0.18 CFM50 per ft2 surface area Flow Coefficient (C) = 565.1 (+/- 1.7 %) Exponent (n) = 0.154 ( +/- 0.004 ) Correlation Coefficient = 0.99890 Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door 1. Estimated Average Annual Infiltration Rate: 246.0 CFM 0.60 ACH 49.2 CFM per person 2. Estimated Design Infiltration Rate: Winter: 251.0 CFM 0.61 ACH Summer: 149.4 CFM 0.37 ACH 3. Recommended Whole Building Mechanical 0.0 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: � - �, � -. BUILDING LEAKAGE TEST Page 3 Date of Test:9/23/2014 Test File: Savant Blower poor Data Points: Data Entered Manually Nominal Temperature Buiicling Fan Pressure Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Std Dev(Pa) -1.1 n/a +/-0.00 -65.0 34.6 1070 1072 0.1 Ring A -60.0 33.6 1055 1057 -0.0 Ring A -55.0 32.6 1040 1042 -0.1 Ring A -50.0 31.7 1025 1027 -0.1 Ring A -45.0 30.7 1010 1012 0.1 Ring A