Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2427 Marshfield Ln - Disclosures/Final Energy - 09/18/2014
2012 IECC Energy Cost Compliance n � Property Organization rxic Journey Homes GS Services 2427 Marshfield (970) 449-1612 Fort Collins, CO 80524 Paul Higman Weather:Ft. Collins, CO Builder 2427 Marshfield Journey Homes Journey Homes 2427 Marshfield Annual Energy Cost $/yr Heating ;• _ 372" , ;:. 395i Cooling,_ 123 - _ 92' Water Heating"`. _ " 392 3921 _ SubTotal-- Used to Determine Compliance,' _ - `� • ` 1886, 8801 Lights Et Appliances 829, ��,., 826 PhotovolYaics , .. 0 ° 0' ,Service Charge - - 240 240' Total 1955 1946.+ Mandatory Requirements Window U-Factor Check (Section 402.5), -' - - . WindowU-Factor (Design must be equal or`lower) � : _ . 6.480 0.320'i .Home Infiltration (Section.402.4.1.2) •" ' , • •= '• �`, ._ PASSES! Duct Leakage (Section 403.2.2) PASSES Mechanical Ventilation,(Section403.S)�. ••° - PASSES; This home MEETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code based on a climate zone of 5B. In fact, this home surpasses the requirements by 0.6%. Digitally signed by:, Paul �DN: CN = Paul Name Paul Higman Signature •l,atQ:H(gman C = US igmanzo,4.og. Organization GS Services Date 18 September 2014 A, 18o7:15:07- Yl Mechanical Systems _--._ ._._ _4.__ — ._m_ ....__ Heating .-„ Fuel -fired air'distnbuton, 58.O.kBtuh, 92;1 AFUE: ,Water Heating Conventional, Elec, 0.91 FF." Cooling Air conditioner, 14.7 kBtuh, 13.0 SEER. l Window -to -Floor Area Ratio: 0.08 Blower door test Htg 859 Clg:°859 CFM50 " In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Design - Residential Energy Analysis Software v14.4.1 This information does not constitute any warranty of energy cost or savings. © 1985-2014 Architectural Energy Corporation, Boulder, Colorado. City of ,,E6rt Collins Planning, Development & Transportation Services Community Development & Neighborhood Services Simulated Performance Alternative (SPA) Cover Sheet Submittal and Rating Type Stock Plan Permit — Projected Worst -Case Rating Lot -specific Permit - Projected Rating 7 Completed Home — Confirmed Rating Data Required for All SPA Ratings Builder: Journey Homes Energy rater: Paul Higman Builder Model: Address: Address: 2427 Marshfield Rating Firm: GS Services Date: 9-17-14 Duct Location Inputs Location Su ply Return % Area R-Value % Area R-Value All within conditioned space 100 0 100 0 Utility Rates Energy Source Service charge Rate Electricity 5 $/month 0.10 $/kWh Natural gas 15 $/month 0.60 $/therm Spaces considered outside the thermal boundary: Additional Information for Stock Plan Permit— Projected Worst -Case Rating "Worst -case" configuration: Foundation Options included Orientation of front elevation HAffach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report Attach REM/Rate Energy Code Inspection Checklist Additional Information for Lot -Specific Permit — Projected Rating ttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report ttach REM/Rate Energy Code Inspection Checklist Additional Information for Completed Home — Confirmed Rating ❑Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report (Utility rates reflected in this report must be City -approved rates on lot -specific permit application date.) ❑Attach Home Energy Rating Certificate Updated 11/09/2012