HomeMy WebLinkAbout2403 Marshfield Ln - Disclosures/Blower Door Test - 09/23/2014Date of Test: 9/23/2014
Customer: Journey Homes
Greeley, CO 80525
Test Results
1. Airflow at 50 Pascals:
(50 Pa = 0.2 w.c.)
2. Leakage Area:
3. Building Leakage Curve:
BUILDING LEAKAGE TEST
GS Services
2000 S College Ave.
Suite 308
Fort Collins, CO 80525
:I
Test File: Journey Homes - 2403 Marshfield - TS1858 - BD
Technician:
Project Number: TS1858
Building Address: 2403 Marshfield
Fort Collins, CO 80525
1104 CFM50 (+/- 6.2 %)
2.25 ACH50
60.7 in2 LBL ELA @ 4 Pa
Flow Coefficient (C) = 35.4 (+/- 43.0 %)
Exponent (n) = 0.880 ( +/- 0.120)
Correlation Coefficient = 0.99088
4. Test Settings: Test Standard: RESNET Multi -Point Test
Test Mode: Depressurization
5. Accuracy Level Standard Level of Accuracy Test
Infiltration Estimates
1. Estimated Average Annual Infiltration Rate:
2. Estimated Design Infiltration Rate:
Cost Estimates
1. Estimated Cost of Air Leakage for Heating:
2. Estimated Cost of Air Leakage for Cooling:
62.4 CFM
0.13 ACH
Winter: 100.6 CFM Summer: 66.7 CFM
0.21 ACH 0.14ACH
Pau I Digitally signed by: Paul
Nigg(nan
DN• CN = Paul Higman
H i g m a nfDafe: 2014.09.24 15:38:
1 1-06-00'
V
GS eemces
- BUILDING LEAKAGE TEST Page of-4
1 `JDDate of Test: 9/23/2014 Test File: Journey Homes - 2403 Marshfield - 151858r��-BD (�5
Building Information Location Climate Information
Volume
29431
Surface Area
Floor Area
2872
Height
18
# of Bedrooms
3
# of Occupants
Year of Construction
2014
Wind Shield
M
Heating and Cooling Cost and Efficiency Information
Heating Fuel Gas
Heating Fuel Cost
Heating Efficiency %
Cooling Fuel Cost
Cooling SEER
Ventilation Weather Factor
0.87
Energy Climate Factor
17.00
Heating Degree Days
6128
Cooling Degree Days
297
Design Winter Wind Speed
7.3 mph
Design Summer Wind Speed
9.4 mph
Design Winter Temp Diff
73 deg F
Design Summer Temp Diff
15 deg F
Equipment Information
Type
Manufacturer
Model
Serial Number
Custom Calibration Date
Fan
Energy Conservatory
I Model 3 (110V)
I
I Default
No Text