HomeMy WebLinkAbout2974 Denver Dr - Disclosures/Final Energy - 08/29/2014Fort Collins Energy Cost Compliance
= Non Electric Heat
Property
Organization
Journey Homes
GS Services
2974 Denver Dr
(970)449-1612
Fort Collins, CO 80525
Paul Higman
Weather:Ft. Collins, CO
Builder
2974 Denver Dr
Journey Homes
Journey Homes 2974 Denver Dr -
Annual Energy Cost
Heating
Cooling
Water Heating
SubTotal - Used to Determine Compliance
Lights & Appliances
Photovoltaics
Service Charge
Total
Q-
4�� 11
5"ervi cam
$/yr
FC 2012
As Designed
429
421'
83
77!
338
3381
850
836'
724
726.
-0 °
-0'.
240 .
240
1814 18021
Mandatory Requirements
Window LT -Factor Check (Section 402.5)
Window U-Factor (Design must be equal or lower) 0.400 0.320,
I Home Infiltration (Section 402.4.2) PASSES
Duct Leakage (Section 403.2.2) PASSES'
This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code,
amended by the City of Fort Collins. In fact, this home surpasses the requirements by 1.6%. Digitally signed
Paul by:,PaulHigman
DjCN = Paul
Name Paul Higman Signature H ig ma' ' lgrnan C = US
Organization GS Services Date 29 August 2014 Date. 2014.08.29
10:27:39-06'00'
Mechanical Systems
Heating
Fuel -fired air distribution, 73.7 kBtuh, 92.1 AFUE.
Cooling
Air conditioner, 24.0 kBtuh, 13.0SEER.
Water Heating
Conventional, Elec, 0.91 EF.
Window -to -Floor Area Ratio:
0.10
Blower door test
Htg: 1532 Clg: 1532 CFM50
In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to
calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the
design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained
periodically to ensure the compliance calculations reflect current federal minimum standards.
REM/Design - Residential Energy Analysis Software vi4.4.1
This information does not constitute any warranty of energy cost or savings.
0 1985-2014 Architectural Energy Corporation, Boulder, Colorado.
City of
t Collins
Planning, Development & Transportation Services
Community Development & Neighborhood Services
Simulated Performance Alternative (SPA) Cover Sheet
Submittal and Rating Type
Stock Plan Permit — Projected Worst -Case Rating
Lot -specific Permit - Projected Rating
Completed Home —Confirmed Rating
Data Required for All SPA Ratings
Builder: Journey Homes
Energy rater:
Paul Higman
Builder Model:
Address:
Address: 2974 Denver
Rating Firm:
GS Services
Date: 8-16-14
Duct Location Inputs
Location
Su ply
Return
% Area
R-Value
% Area
R-Value
All within conditioned space
100
0
100
0
Utility Rates
Enerav Source I
Service char a
I Rate
Electricity
5 $/month
0.10 $/kWh
Natural gas
15 $/month
0.60 $/therm
Spaces considered outside the thermal boundary:
Additional Information for Stock Plan Permit — Projected Worst -Case Rating
"Worst -case" configuration:
Foundation type(s)
Options included
Orientation of front elevation
eAttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report
Attach REM/Rate Energy Code Inspection Checklist
Additional Information for Lot -Specific Permit — Projected Rating
ttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report
ttach REM/Rate Energy Code Inspection Checklist
Additional Information for Completed Home — Confirmed Rating
❑Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report
(Utility rates reflected in this report must be City -approved rates on lot -specific permit application date.)
❑Attach Home Energy Rating Certificate
Updated 11/09/2012