HomeMy WebLinkAbout3814 Rock Creek Dr - Disclosures/Air Sealing - 03/27/2012 (3)Date of Test: 3-27-12 Test File: Landmark 3814 Rock Creek F Customer: Landmark Homes Phone Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Minneapolis Leakage Ratio: 4. Building Leakage Curve: 5. Test Settings: BUILDING LEAKAGE TEST Thermal Concepts P.O. Box 270066 Fort Collins, CO 80527 Phone:970-223-7090 Technician: Paul Higman Building Address: 3814 Rock Creek Unit F Fort Collins, CO 80528 1464 CFM (+/- 1.0 %) 3.62 ACH 0.56 CFM per ft2 floor area 141.5 in2 ( +/- 3.2 %) Canadian EgLA @ 10 Pa 72.4 in2 (+/- 5.3 %) LBL ELA @ 4 Pa 0.00 CFM50 per ft2 surface area Flow Coefficient (C) = 98.0 ( +/- 8.5 %) Exponent (n) = 0.691 ( +/- 0.023 ) Correlation Coefficient = 0.99658 Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door, S/N 9876 Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 83.8 CFM 0.21 ACH 2. Estimated Design Infiltration Rate: Winter: 122.4 CFM 0.30 ACH Summer: 69.6 CFM 0.17 ACH t 3. Recommended Whole Building Mechanical 32.7 CFM Ventilation Rate: (based on ASH RAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 3-27-12 Test File: Landmark 3814 Rock Creek F Building Conditions Inside Temperature: 68 deg F Heating Fuel: Gas Outside Temperature: 48 deg F Heating Fuel Cost: # of Stories 2.0 Heating Efficiency: Heating Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: # of Occupants Cooling SEER: Cooling Degree Days: 287 # of Bedrooms: 2.0 Volume: 24304 ft3 Ventilation Weather Factor: 0.87 Surface Area: Energy Climate Factor: 17.0 Floor Area: 2604 ft2 Design Winter Wind Speed: 9.0 mph Design Winter Temp Diff: 69 deg F Design Summer Wind Speed: 7.0 mph Design Summer Temp Diff: 16 deg F Comments 0 V l BUILDING LEAKAGE TEST Page 3 Date of Test: 3-27-12 Test File: Landmark 3814 Rock Creek F Data Points: Nominal Temperature Building Fan Pressure Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Std Dev (Pa) 0.0 n/a +/- 0.30 -50.1 65.2 1458 1430 -1.9 Ring A -46.0 59.8 1397 1370 -0.3 Ring A -44.1 57.2 1367 1341 0.5 Ring A -35.9 44.2 1205 1182 2.4 Ring A -31.3 36.9 1104 1083 3.0 Ring A -25.9 240.7 918 901 -2.0 Ring B -20.1 172.5 778 764 -0.7 Ring B -14.5 103.0 603 592 -3.0 Ring B -0.8 n/a +/- 0.19 Building Leakage (Cfm) Building Leakage Curve Thermal Concepts P.O. Box 270066 Fort Collins, CO 80527 Phone: 970-223-7090 Date of Test: 3-27-12 Test File: Landmark 3814 Rock Creek F n 4 5, 6 7 8 9 10 20 30 40 50 60 Building Pressure (Pa)