Loading...
HomeMy WebLinkAbout3814 Rock Creek Dr - Disclosures/Air Sealing - 03/27/2012 (2)Date of Test: 3-27-12 Test File: Landmark 3814 Rock Creek E Customer: Landmark Homes :11,=1 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Minneapolis Leakage Ratio: 4. Building Leakage Curve: BUILDING LEAKAGE TEST Thermal Concepts P.O. Box 270066 Fort Collins, CO 80527 Phone: 970-223-7090 Technician: Paul Higman Building Address: 3814 Rock Creek Unit E Fort Collins, CO 80528 1686 CFM (+/- 1.0 %) 4.70 ACH 0.73 CFM per ft2 floor area 102.9 in2 ( +/- 3.3 %) Canadian EgLA @ 10 Pa 40.6 in2 (+/- 5.5 %) LBL ELA @ 4 Pa 0.00 CFM50 per ft2 surface area Flow Coefficient (C) = 36.9 ( +/- 8.9 %) Exponent (n) = 0.977 ( +/- 0.025 ) Correlation Coefficient = 0.99842 5. Test Settings: Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door, S/N 9876 Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 46.9 CFM 0.13ACH 2. Estimated Design Infiltration Rate: Winter: 68.6 CFM 0.19ACH Summer: 39.0 CFM 0.11 ACH 3. Recommended Whole Building Mechanical 45.1 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling:. BUILDING LEAKAGE TEST Page 2 Date of Test: 3-27-12 Test File: Landmark 3814 Rock Creek E Building Conditions Inside Temperature: 68 deg F Outside Temperature: 48 deg F # of Stories 2.0 Wind Shield: M # of Occupants # of Bedrooms: 2.0 Volume: 21513 ff3 Surface Area: Floor Area: 2305 ft2 Design Winter Wind Speed: 9.0 mph Design Summer Wind Speed: 7.0 mph Comments Heating Fuel: Gas Heating Fuel Cost: Heating Efficiency: Heating Degree Days: 6020 Cooling Fuel Cost: Cooling SEER: Cooling Degree Days: 287 Ventilation Weather Factor: 0.87 Energy Climate Factor: 17.0 Design Winter Temp Diff: 69 deg F Design Summer Temp Diff. 16 deg F BUILDING LEAKAGE TEST Page 3 Date of Test: 3-27-12 Test File: Landmark 3814 Rock Creek E Data Points: Data Entered Manually Nominal Temperature Building Fan Pressure Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Std Dev (Pa) -1.5 n/a N +/- 0.00 -50.2 86.2 1670 1638 1.4 Ring A -45.1 65.9 1465 1437 -0.7 Ring A -41.3 53.9 1328 1303 -1.4 Ring A -35.0 38.1 1122 1101 -1.0 Ring A -29.5 27.9 964 946 1.8 Ring A -25.2 173.6 781 766 -2.4 Ring B -16.7 78.8 528 518 4.0 Ring B -3.2 n/a +/- 0.00 a Building Leakage WITI) Building Leakage Curve Thermal Concepts P.O. Box 270066 Fort Collins, CO 80527 Phone: 970-223-7090 Date of Test: 3-27-12 Test File: Landmark 3814 Rock Creek E 4 5 6 7 8 9 10- 20 30 40 50 60 Building Pressure (Pa)