HomeMy WebLinkAbout3814 Rock Creek Dr - Disclosures/Air Sealing - 03/27/2012 (6)BUILDING LEAKAGE TEST Thermal Concepts P.O. Box 270066 Fort Collins, CO 80527 Phone: 970-223-7090 Date of Test: 3-27-12 Technician: Paul Higman Test File: Landmark 3814 Rock Creek C Customer: Landmark Homes Phone Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Minneapolis Leakage Ratio: 4. Building Leakage Curve: Building Address: 3814 Rock Creek Unit C Fort Collins, CO 80528 1638 CFM (+/- 2.1 %) 4.78 ACH 0.74 CFM per ft2 floor area 94.8 in2 (+/- 6.4 %) Canadian EgLA @ 10 Pa 36.2 in2 (+/- 10.7 %) LBL ELA @ 4 Pa 0.00 CFM50 per ft2 surface area Flow Coefficient (C) = 31.5 ( +/- 17.3 %) Exponent (n) = 1.010 ( +/- 0.048 ) Correlation Coefficient = 0.99327 5. Test Settings: Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door, S/N 9876 Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 41.9 CFM 0.12 ACH 2. Estimated Design Infiltration Rate: Winter: 61.2 CFM 0.18ACH Summer: 34.8 CFM 0.10 ACH 3. Recommended Whole Building Mechanical 44.5 CFM Ventilation Rate: (based on ASH RAE 62.2) c Cost Estimates 1. Estimated Cost of Air Leakage for Heating 2. Estimated Cost of Air Leakage for Cooling BUILDING LEAKAGE TEST Paae 2 Date of Test: 3-27-12 Test File: Landmark 3814 Rock Creek C Building Conditions Inside Temperature: 68 deg F Heating Fuel: Gas Outside Temperature: 48 deg F Heating Fuel Cost: # of Stories 2.0 Heating Efficiency: Heating Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: # of Occupants Cooling SEER: Cooling Degree Days: 287 # of Bedrooms: 2.0 Volume: 20543 ff3 Ventilation Weather Factor: 0.87 Surface Area: Energy Climate Factor: 17.0 Floor Area: 2201 ft2 Design Winter Wind Speed: 9.0 mph Design Winter Temp Diff: 69 deg F Design Summer Wind Speed: 7.0 mph Design Summer Temp Diff: 16 deg F Comments a BUILDING LEAKAGE TEST Page 3 Date of Test: 3-27-12 Test File: Landmark 3814 Rock Creek C Data Points: Data Entered Manually Nominal Temperature Building Fan Pressure Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Std Dev (Pa) -1.5 n/a +/- 0.00 -50.9 74.2 1552 1522 -3.2 Ring A -44.8 61.4 1416 1389 1.4 Ring A -41.3 54.9 1340 1314 4.7 Ring A -35.4 34.0 1061 1041 -1.8 Ring A -30.4 235.8 909 892 -0.5 Ring B -26.7 187.3 811 795 2.8 Ring B -21.1 83.7 544 534 -9.6 Ring B -17.1 63.9 476 467 1.6 Ring B -4.3 n/a +/- 0.00 n Building Leakage (Cfm) Building Leakage Curve Thermal Concepts P.O. Box 270066 Fort Collins, CO 80527 Phone: 970-223-7090 Date of Test: 3-27-12 Test File: Landmark 3814 Rock Creek C 2000 I I I I I I I 1000 ---i---rt----;--r-t--------------r--- 900 --- ;--- 1--------------L--- 800 ---1---1--J--1--L-1--------------L-- I I I I I I I 700---1---1-------1--------------L -- 600 I I I I I I I I I 500---rtI I yI I I I --- -- -- -Ir --- I I I I I I I ------------L400--- I I I I I I I I I f I I I I I I I I I I, I I I I I I I I I I I I ___ i I I i i t I 200 r--- ----1--r-+--------------L--- I I I I I I I I I I I I I I I I I I I I I 100 I I I I I I 1 4 5 6 7 8 9 10 20 Building Pressure (Pa) 30 40 50 60