HomeMy WebLinkAbout3814 Rock Creek Dr - Disclosures/Air Sealing - 03/27/2012 (4)Date of Test: 3-27-12 Test File: Landmark 3814 Rock Creek Customer: Landmark Homes Phone Test Results BUILDING LEAKAGE TEST Thermal Concepts P.O. Box 270066 Fort Collins, CO 80527 Phone: 970-223-7090 Technician: Paul Higman Building Address: 3814 Rock Creek UnitA Fort Collins, CO 80528 1. Airflow at 50 Pascals: 1494 CFM (+/- 1.6 %) (50 Pa = 0.2 w.c.) 3.69ACH 0.57 CFM per ft2 floor area 2. Leakage Areas: 128.5 in2 ( +/- 5.7 %) Canadian EgLA @ 10 Pa 61.6 in2 (+/- 9.6 %) LBL ELA @ 4 Pa 3. Minneapolis Leakage Ratio: 0.00 CFM50 per ft2 surface area 4. Building Leakage Curve: Flow Coefficient (C) = 75.5 ( +/-15.4 %) Exponent (n) = 0.763 ( +/- 0.043 ) Correlation Coefficient = 0.99232 5. Test Settings: Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door, S/N 9876 Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 71.3 CFM 0.18ACH 2. Estimated Design Infiltration Rate: Winter: 104.1 CFM 0.26 ACH Summer: 59.2 CFM 0.15ACH 3. Recommended Whole Building Mechanical 38.9 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 0 pppppp� BUILDING LEAKAGE TEST Page 2 Date of Test: 3-27-12 Test File: Landmark 3814 Rock Creek A Building Conditions Inside Temperature: 68 deg F Heating Fuel: Gas Outside Temperature: 48 deg F Heating Fuel Cost: # of Stories 2.0 Heating Efficiency: Heating Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: # of Occupants Cooling SEER: l Cooling Degree Days: 287 # of Bedrooms: 2.0 Volume: 24304 ff3 Ventilation Weather Factor: 0.87 Surface Area: Energy Climate Factor: 17.0 Floor Area: 2604 ft2 Design Winter Wind Speed: 9.0 mph Design Winter Temp Diff: 69 deg F Design Summer Wind Speed: 7.0 mph Design Summer Temp Diff: 16 deg F Comments 0 pppppp� BUILDING LEAKAGE TEST Page 3 Date of Test: 3-27-12 Test File: Landmark 3814 Rock Creek Data Points: Nominal Temperature Building Fan Pressure Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Std Dev (Pa) -0.9 n/a +/- 0.46 -48.7 65.4 1459 1431 -1.0 Ring A -45.9 59.9 1399 1372 -0.6 Ring A -41.2 50.7 1289 1265 -0.3 Ring A -35.2 42.4 1181 1158 3.1 Ring A -28.5 30.7 1009 990 4.2 Ring A -27.4 25.6 923 905 -1.9 Ring A -21.6 16.0 734 720 -5.6 Ring A -0.8 n/a +/- 0.66 ppppppp- Building Leakage WITI) Building Leakage Curve Thermal Concepts P.O. Box 270066 Fort Collins, CO 80527 Phone: 970-223-7090 Date of Test: 3-27-12 Test File: Landmark 3814 Rock Creek A 2000 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1000---4---------{--E---------------�---- I I I I I I I 900 --- ---1-- -- -- - -------------- L---- -------------- 700-----4 ------rt----r--r—t--------------r— -- --- I. I- I 1 I I I I I I I I I 600------rt------r-t-------------;---- I I I I I I I I I I I I I I 500-=----7------{--+-------------r---- 400---4--- 4--�--�---------------- �---- I I I I I I I I I I I I I I I I I I I I 300 ----1-�--�--�-�--------------�---- I I I I I 1 I 1 1 4 5 6 7 8 9 10 20 Building Pressure (Pa) KZ; ��I 40 50 60