HomeMy WebLinkAbout322 Newaygo Dr - Disclosures/Final Energy - 06/28/2012� y
MMl
Contractor
Services
FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT
Date: June 29, 2012
Rating No.:
Building Name: 322 Newaygo
Rating Org.:
Thermal Concepts
Owner's Name: Encore Homes
Phone No.:
970-223-7090
Property: 322 Newaygo
Rater's Name:
Paul Higman
Address: Fort Collins, CO 80524
Rater's No.:
6784592
Builder's Name: Encore Homes LLC
Weather Site: Ft. Collins, CO
Rating Type:
Confirmed Rating
File Name: Encore Homes 322 Newaygo_Remington_final.blc
Rating Date:
6-28-12
Annual Energy Cost ($)
FC 2012 As Designed
Heating:
296
268
Cooling:
84
75
Water Heating:
103
108
SubTotal - Used to Determine Compliance:
483
451
Lights & Appliances:
622
624
Photovoltaics:
-0
-0
Service Charge:
120
120
Total:
1225
1195
Window U-Factor Check (Section 402.5)
Window U-Factor (Design must be equal or lower): 0.400 0.334
Home Infiltration (Section 402.4.2): PASSES
Duct Leakage (Section 403.2.2): PASSES
This home MEETS the annual energy cost requirements and verifications of Section 405 of the 2009 International Energy
Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 6.7%.
Name: Paul Higman Signature:
Organization: Thermal Concepts Date: June 29, 2012
Design energy cost is based on the following systems: Paul
Heating: Fuel -fired air distribution, 66.0 kBtuh, 92.1 AFUE. o Cooling: Air conditioner, 24.0 kBtuh, 13.0 SEER. Higman
Water Heating: Conventional, Gas, 0.58 EF. Signature
Window -to -Floor Area Ratio: 0.14
Blower door test: Htg:915CIg:915CFM50 not verified!
REM/Rate - Residential Energy Analysis and Rating Software v12.97
This information does not constitute any warranty of energy cost or savings.
01985-2012 Architectural Energy Corporation, Boulder, Colorado.
Digitally signed by:
Paul Higman
DN: CN = Paul Higman
C = AD O = Thermal
Concepts
Date: 2012.06.29 08:
42:48-07'00'
Reason: I am the
author of this document
.,
FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT
322 Newaygo
Page 2
In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed
prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set
equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software
updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards.
REM/Rate - Residential Energy Analysis and Rating Software v12.97
This information does not constitute any warranty of energy cost or savings.
01985-2012 Architectural Energy Corporation, Boulder, Colorado.
322 Newaygo
MSM VV" 322 Newaygo
Contractor
�rViCCS Fort Collins, CO 80524
Uniform Energy Rating System
5 Stars
Confirmed Rating
Energy Efficient
1 Star
1 Star Plus
2 Stars
2 Stars Plus
3 Stars
3 Stars Plus
4 Stars
4 Stars Plus
5 Stars
5 Stars Plus
50OA01
400-301
300-251
250-201
200-151
150-101
100-91
90-86
85-71
70 or Less
HERS Index:
Conditioned Area:
1569 sq. ft. HouseType:
Single-family detached
Conditioned Volume:
16170 cubic ft. Foundation:
Conditioned crawl space
Bedrooms:
3
kMechanical Systems Features
Heating:
Fuel -fired air distribution, Natural gas, 92.1 AFUE.
Cooling:
Air conditioner, Electric, 13.0 SEER.
Water Heating:
Conventional, Natural gas, 0.58 EF, 40.0 Gala
Duct Leakage to Outside:
45.00 CFM.
Ventilation System:
Exhaust Only: 64 cfm, 24.0 wafts.
Programmable Thermostat:
Heating: Yes Cooling: Yes
Building Shell Features
Ceiling Flat:
R-38 Exposed Floor:
R-38
Vaulted Ceiling:
NA Window Type:
U.0.33,SHGC0.31
Above Grade Walls:
R-19, R-15 Infiltration:
Foundation Walls:
R-19.0 Rate:
Htg: 915 Clg: 915 CFM50
Slab:
None Method:
Blower door test
Percent Interior Lighting: 0.00 Range/Oven Fuel: Electric
Percent Exterior Lighting: 0.00 Clothes Dryer Fuel: Electric
Refrigerator (kWh/yr): 575.00 Clothes Dryer EF: 3.01
Dishwasher Energy Factor: 0.64 Ceiling Fan (cfm/Watt): 0.00
The Home Energy Rating Standard Disclosure for this home is available from the rating provider.
REM/Rate - Residential Energy Analysis and Rating Software v12.97
This information does not constitute any warranty of energy cost or savings.
01985-2012 Architectural Energy Corporation, Boulder, Colorado.
Registry ID:
Rating Number:
Certified Energy Rater: Paul Higman
Rating Date: 6-28-12
Rating Ordered For: Encore Homes
Estimated Annual Energy Cost
Confirmed Rating
Use
MMBtu
Cost
Percent
Heating
42.0
$231
20%
Cooling
2.2
$61
5%
Hot Water
21.6
$108
10%
Lights/Appliances
22.1
$614
54%
Photovoltaics
-0.0
$-0
-0%
Service Charges
$120
11 %
Total
$1134
100%
This home meets or exceeds the minimum
criteria for all of the following:
2006 International Energy Conservation Code
2009_ International Energy Conservation Code
- i Digitally signed
Masco Home Services
by: Paul
Higman
DN: CN = Paul
Y1Pau.l'
C
2339 Beville Rd
/ i
ADO=,-
Daytona Beach, FL. 32119
386-304-2200
Signatu
Higman
Thermal
concepts
Date:2012.06.
29 08:42:58 -
re not
grog•
verified!
Reason: I am
the author or
this document
V Ra&�lr
�%' r &v,,,
, 322 Newaygo
MMSCO 322 Newaygo
Contractor Fort Collins, CO 80524
Services
lk- _cw
5 Stars
Confirmed Rating
Uniform Energy Rating System Energy Efficient
1 Star 1 Star Plus 1 2 Stars 2 Stars Plus 3 Stars 13 Stars Plus 4 Stars 1:4:S:tars Plus 5 Stars 5 Stars Plus
500�01 400-301 300-251 250-201 1200-151 150-101 I 100-91 90_86 85-71 70 or Less
HERS Index: 74
General Information
Conditioned Area: 1569 sq. ft. HouseType: Single-family detached
Conditioned Volume: 16170 cubic ft. Foundation: Conditioned crawl space
Bedrooms: 3
Mechanical Systems Features
Heating: Fuel -fired air distribution, Natural gas, 92.1 AFUE.
Cooling: Air conditioner, Electric, 13.0 SEER.
Water Heating: Conventional, Natural gas, 0.58 EF, 40.0 Gal.
Duct Leakage to Outside: 45.00 CFM.
Ventilation System: Exhaust Only: 64 cfm, 24.0 watts.
Programmable Thermostat: Heating: Yes Cooling: Yes
Building Shell Features
Ceiling Flat: R-38 Exposed Floor: R-38
Vaulted Ceiling: NA Window Type: U.0.33,SHGC0.31
Above Grade Walls: R-19, R-15 Infiltration:
Foundation Walls: R-19.0 Rate: Htg: 915 Clg: 915 CFM50
Slab: None Method: Blower door test
Lights and Appliance Features
Percent Interior Lighting 0.00 Range/Oven Fuel Electric
Percent Exterior Lighting: 0.00 Clothes Dryer Fuel. Electric
Refrigerator (kWh/yr): 575.00 Clothes Dryer EF: 3.01
Dishwasher Energy Factor: 0.64 Ceiling Fan (cfm/Watt): 0.00
The Home Energy Rating Standard Disclosure for this home is available from the rating provider.
REM/Rate - Residential Energy Analysis and Rating Software v12.97
This information does not constitute any warranty of energy cost or savings.
0 1985-2012 Architectural Energy Corporation, Boulder, Colorado.
Registry ID:
Rating Number:
Certified Energy Rater:
Paul Higman
Rating Date:
6-28-12
Rating Ordered For:
Encore Homes
Estimated Annual Energy CostT
Confirmed
Rating
Use
MMBtu
Cost
Percent
Heating
42.0
$231
20%
Cooling
2.2
$61
5%
Hot Water
21.6
$108
10%
Lights/Appliances.
22.1
$614
54%
Photovoltaics
-0.0
$-0
-0%
Service Charges
$120
11 %
Total
$1134
100%
This home meets or exceeds the minimum
criteria for all of the following:
2006 International Energy Conservation Code
2009 International Energy Conservation Code
---------- —
-- ----- ---- -- —Digitally signed
by: Paul
Higman
Masco Home Services
Paul,
fs-
=Paul
Higmanan C =
Hig
2339 Beville Rd
° A� f ADO =
Daytona Beach, FL. 32119
y
Thermal
Concepts
H i gf p'
386-304-2200
LA 201
Signatu 2908:2:58-
� 29 08:42:58 -
re not 07'00'
Reason: I am
Verified! the author of
' this document