HomeMy WebLinkAbout2320 Nancy Gray Ave - Disclosures/Air Sealing - 06/20/201261 &� s /g(')�rC)RO
Date:
Building Name:
Owners Name:
Property:
Address:
Builders Name:
Weather Site:
File Name:
June 20, 2012
m,nergyLogic
analysis. Insight. answers.
AIR LEAKAGE REPORT
Rating No.: 25302
Jamestown Builders
Rating Org.:
Jamestown Homeowner
Phone No.:
2320 Nancy Gray Ave
Raters Name:
Ft Collins, CO 80525
Raters No.:
Jamestown Builders
Ft. Collins, CO
Rating Type:
2320 Nancy Gray Ave - Jamestown Builders - REP
Rating Date:
Whole House Infiltration
Duct Leakage
Ventilation
EnergyLogic, Inc.
970.532.3220 1.800.315.0459
Peter Oberhammer
9189857
Confirmed
06/19/12
Blower door test
Heating
Cooling
Natural ACH:
0.09
0.07
ACH @ 50 Pascals:
1.51
1.51
CFM @ 25 Pascals:
396
396
CFM @ 50 Pascals:
621
621
Eff. Leakage Area: [sq.in]
34.1
34.1
Specific Leakage Area:
0.000091
0.00009
ELA/100 sf shell: [sq.in]
0.661
0.66
Leakage to Outside Units
CFM @ 25 Pascals:
18
CFM25 / CFMfan:
0.0213
CFM25 /CFA:
0.0066
CFM per Std 152:
WA
CFM per Std 152 / CFA:
N/A
CFM @ 50 Pascals:
28
Eff. Leakage Area: [sq.in]
1.55
Thermal Efficiency:
N/A
Total Duct Leakage Units
CFM25/CFA
Total Duct Leakage:
0.0211
Mechanical:
Exhaust Only
Sensible Recovery Eff. (%):
0.0
Total Recovery Eff. (%):
0.0
Rate (cfm):
57
Hours/Day:
24.0
Fan Watts:
15.0
Cooling Ventilation:
No Ventilation
ASHRAE 62.2 - 2010 Ventilation Requirements
For this home to comply with ASHRAE Standard 62.2 - 2010 Ventilation and Acceptable Indoor Air Quality in Low -Rise
Residential Buildings, a minimum of 57 cfm of mechanical ventilation must be provided continuously, 24 hours per day.
Alternatively, an intermittently operating mechanical ventilation system may be used if the ventilation rate is adjusted
accordingly. For example, a 115 cfm mechanical ventilation system would need to operate 12 hours per day, as long as
the system operates to provide required average ventilation once each hour.
REMIRate - Residential Energy Analysis and Rating Software 02.99
This information does not constitute any warranty of energy cost or savings.
®1985-2012 Architectural Energy Corporation, Boulder, Colorado.