Loading...
HomeMy WebLinkAbout534 Coyote Trail Dr - Disclosures/Air Sealing - 05/23/2012BUILDING LEAKAGE TEST Thermal Concepts 6617 S. College ave Fort Collins, CO 80525 Phone: 970-223-7090 Date of Test: 5-23-12 1 Technician: Paul Higman Test File: Journey Homes 534 Coyote Trail BD final Customer: Journey Homes Building Address: 563 San Juan Dr Fort Collins, CO 80525 Greeley, CO 80634 Phone Test Results 1. Airflow at 50 Pascals: (56 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Minneapolis Leakage Ratio: 4. Building Leakage Curve: 5. Test Settings: 1450 CFM (+/- 0.6 %) 3.41 ACH 0.57 CFM per ft2 floor area )164.8 in2 ( +/- 2.3 %) Canadian EgLA @ 10 Pa 92.5in2(+/-3.8%)LBLELA@4Pa 0.00 CFM50 per ft2 surface area Flow Coefficient (C) = 143.9 ( +/- 6.1 %) Exponent (n) = 0.590 ( +/- 0.017 ) Correlation Coefficient = 0.99843 Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door, S/N 9876 Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Winter: Summer: 3. Recommended Whole Building Mechanical Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 115.1 CFM 0.27 ACH 156.4 CFM 0.37 ACH 88.8 CFM 0.21 ACH 23.3 CFM C BUILDING LEAKAGE TEST Page 2 Date of Test: 5-23-12 Test File: Journey Homes 534 Coyote Trail BD final Building Conditions Inside Temperature: 72 deg F Heating Fuel: Gas Outside Temperature: 65 deg F Heating Fuel Cost: # of Stories 2.0 Heating Efficiency: Heating Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: # of Occupants Cooling SEER: Cooling Degree Days: 287 # of Bedrooms: 3.0 Volume: 25536 ft3 Ventilation Weather Factor: 0.87 Surface Area: Energy Climate Factor: �17.0 Floor Area: 2544 ft2 Design Winter Wind Speed: 9.0 mph Design Winter Temp Diff: 69 deg F Design Summer Wind Speed: 7.0 mph Design Summer Temp Diff: 16 deg F Comments House wrt Garage = -47pa House wrt Mech room = Electric water heater BUILDING LEAKAGE TEST Page 3 Date of Test: 5-23-12 Test File: Journey Homes 534 Coyote Trail BD final Data Points: Data Entered Manually Nominal Temperature Building Fan Pressure Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Std Dev (Pa) -0.9 n/a +/- 0.00 -50.2 64.7 1452 1442 0.0 Ring A -45.2 57.3 1368 1359 0.3 Ring A -40.1 48.1 1256 1248 -1.0 Ring A -35.6 42.6 1184 1176 0.2 Ring A -29.9 35.1 1078 1071 1.4 Ring A -25.4 259.9 954 948 -1.0 Ring B -0.4 n/a +/- 0.00 G