Loading...
HomeMy WebLinkAbout393 Bannock St - Disclosures/Air Sealing - 05/09/2012BUILDING LEAKAGE TEST Thermal Concepts P.O. Box 270066 Fort Collins, CO 80527 Phone: 970-223-7090 Date of Test: 5-9-12 Technician: Paul Higman Test File: Encore Homes 393 Bannock 1843 final BD Customer: Encore Homes Building Address: 393 Bannock Fort Collins, CO 80524 Windsor, CO 80550 Phone Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Minneapolis Leakage Ratio 4. Building Leakage Curve: 5. Test Settings: Infiltration Estimates 1058 CFM (+/- 0.5 %) 3.64 ACH 0.55 CFM per ft2 floor area 101.7 in2 ( +/- 1.8 %) Canadian EgLA @ 10 Pa 51.9in2(+/-3.0%)LBLELA@4Pa 0.00 CFM50 per ft2 surface area Flow Coefficient (C) = 69.9 ( +/- 4.8 %) Exponent (n) = 0.695 ( +/- 0.013 ) Correlation Coefficient = 0.99896 Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door, S/N 9876 1. Estimated Average Annual Infiltration Rate: 57.9 CFM 0.20 ACH 2. Estimated Design Infiltration Rate: Winter: 87.7 CFM 0.30 ACH Summer: 49.8 CFM 0.17 ACH 3. Recommended Whole Building Mechanical 47.3 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating 2. Estimated Cost of Air Leakage for Cooling BUILDING LEAKAGE TEST Page 2 Date of Test: 5-9-12 Test File: Encore Homes 393 Bannock-1 843final BD Building Conditions Inside Temperature: 70 deg F Outside Temperature: 72 deg F # of Stories 2.0 Wind Shield: M # of Occupants # of Bedrooms: 4.0 Volume: 17424 ft3 Surface Area: Floor Area: 1936 ft2 Design Winter Wind Speed: 9.0 mph Design Summer Wind Speed: 7.0 mph Comments House wrt Garage = -48pa House wrt Mech = mechanical room is outside Heating Fuel: Gas Heating Fuel Cost: Heating Efficiency: Heating Degree Days: 6020 Cooling Fuel Cost: Cooling SEER: Cooling Degree Days: 287 Ventilation Weather Factor: 0.87 Energy Climate Factor: 17.0 Design Winter Temp Diff: 69 deg F Design Summer Temp Diff: 16 deg F BUILDING LEAKAGE TEST Page 3 Date of Test: 5-9-12 Test File: Encore Homes 393 Bannock 1843 final BD Data Points: Data Entered Manually Nominal Temperature Building Fan Pressure Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Std Dev (Pa) -1.0 n/a +/- 0.00 -55.2 37.8 1117 1119 -0.1 Ring A -51.2 33.6 1055 1057 -0.5 Ring A -45.8 28.6 975 977 -0.5 Ring A -40.0 236.3 910 912 2.2 Ring B -34.3 181.3 798 800 -0.0 Ring B -30.5 152.3 732 733 -0.3 Ring B -25.5 118.4 646 647 0.1 Ring B -20.8 85.5 550 551 -1.3 Ring B -0.8 n/a +/- 0.00