HomeMy WebLinkAbout557 San Juan Dr - Disclosures/Final Energy - 05/08/2012557 San Juan or •
MASCID 557 San Juan or
Contractor
SerV1tJPS Fort Collins, CO 80525
Uniform Energy Rating System
5 Stars Plus
Confirmed Rating
Energy Efficient
1 Star
1 Star Plus
2 Stars
2 Stars Plus
3 Stars
3 Stars Plus
4 Stars
4 Stars Plus
5 Stars
5 Stars Plus
500-401
400-301
300-251
250-201
200-151
150-101
100-91
90-86)
85-71
70 or Less
HERS Index: 66
General information
Conditioned Area: 3510 sq. ft. HouseType: Single-family detached
Conditioned Volume: 32798 cubic ft. Foundation: Conditioned basement
Bedrooms: 3
Heating: Fuel -fired air distribution, Natural gas, 92.1 AFUE.
Water Heating: Conventional,.Electric, 0.95 EF, 50.0 Gal.
Duct Leakage to Outside: 60.00 CFM.
Ventilation System: Exhaust Only: 83 cfm, 24.0 watts.
Programmable Thermostat: Heating: No Cooling: No
Ceiling Flat: R-38
Exposed Floor: NA
Vaulted Ceiling: R-38
Window Type: U:0.34,SHGC:0.31
Above Grade Walls: R-15, R-19
Infiltration:
Foundation Walls: R-11.0, R-0.0, R-13.0
Rate: Htg: 1244 Clg: 1244 CFM50
Slab: R-10.0 Edge, R-0.0 Under
Method: Blower door test
Lights and Appliance FeaturesSWEEMNIM
Percent Interior Lighting: 0.00 -
Range/Oven Fuel: Electric
Percent Exterior Lighting: 0.00
Clothes Dryer Fuel: Electric
Refrigerator (kWh/yr): 575.00
Clothes Dryer EF: 3.01
Dishwasher Energy Factor: 0.64
Ceiling Fan (cfm/Watt): 0.00
The Home Energy Rating Standard Disclosure for
this home is available from the rating provider.
REM/Rate - Residential Energy Analysis and Rating Software v12.97
This information does not constitute any warranty of energy cost or savings.
01985-2012 Architectural Energy Corporation, Boulder, Colorado.
Registry to:
Rating Number:
Certified Energy Rater: Paul Higman
Rating Date: 5-8-12
Rating Ordered For: Journey Homes
Estimated Annual Energy Cost
Confirmed Rating
Use MMBtu Cost
Percent
Heating 65.9 $438
24%
Cooling 0 $0
0%
Hot Water 13.3 $341
19%
Lights/Appliances 33.7 $862
47%
Photovoltaics -0.0 $-0
-0%
Service Charges $198
11%
Total $1839
100%
Ill
This home meets or exceeds the minimum
criteria for all of the following:
2006 International Energy Conservation Code
2009 International Energy Conservation Code
Digitally signed
Paul
Hlgman
ig
Masco Home Services F )
Paul'
DN: CN = Paul
.
Higman C=
2339 Beville Rd ,
...- 7—
ADO =
Daytona Beach, FL. 32119
386-304-2200 Signatu
H Hi
_��• Thermal
gm m a n Concepts
Date:2012.05.
3012:24:06 -
re not
07'00'
verified!
Reason: I am
the author or
this document
MASC,O
Contractor
4 Services
FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT
Date: May 30, 2012
Rating No.:
Building Name: 557 San Juan Dr
Rating Org.:
Thermal Concepts
Owner's Name: Journey Homes
Phone No.:
9i 70-223-7090
Property: 557 San Juan Dr
Raters Name:
Paul Higman
Address: Fort Collins, CO 80525
Rater's No.:
6784592
Builder's Name: Journey Homes
Weather Site: Ft. Collins, CO
Rating Type:
Confirmed Rating
File Name: Journey Homes 557 San Jaun Dr_1626 final.big
Rating Date:
5-8-12
Annual Energy Cost ($)
FC 2012 As Designed
Heating:
532
506
Cooling:
152
94
Water Heating:
347
343
SubTotal - Used to Determine Compliance:
1031
943
Lights & Appliances:
900
886
Photovoltaics:
-0
-0
Service Charge:
198
198
Total:
2128
2027
Window U-Factor Check (Section 402.5)
Window U-Factor (Design must be equal or lower):
0.400
0.340
Home Infiltration (Section 402.4.2):
Duct Leakage (Section 403.2.2):
This home MEETS the annual energy cost requirements and verifications of Section 405 of the 2009 International Energy
Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 8.6%.
Name:' Paul Higman
Organization: Thermal Concepts
Signature:
Date: May 30, 2012
�.,
Design energy cost is based on the following systems: ( \J
Heating: Fuel -fired air distribution, 58.0 kBtuh, 92.1 AFUE. �,y� i„ ce
Water Heating: Conventional, Elec, 0.95 EF. H I g 1' 1 I Q 1 1
Cooling: Air conditioner, 16.5 kBtuh, 13.0 SEER. SlgnatUre ��y ,
Window -to -Floor Area Ratio: 0.11
Blower door test Htg: 1244 Clg: 1244 CFM50 not verified! i
REM/Rate - Residential Energy Analysis and Rating Software v12.97
This information does not constitute any warranty of energy cost or savings.
01985-2012 Architectural Energy Corporation, Boulder, Colorado.
PASSES
PASSES
Digitally signed by:
vaui migman
DN: CN = Paul Higman
C = AD O = Thermal
Concepts
Date: 2012.05.30 12:
23:56 -07"00'
Reason: I am the
author of this document
FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT
557 San Juan Dr
Page 2
In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed
prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set
equal to those in the design home as specked in the 2009 IECC. These standards are subject to change, and software
updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards.
REM/Rate • Residential Energy Analysis and Rating Software v12.97
\This information does not constitute any warranty of energy cost or savings.
019852012 Architectural Energy Corporation, Boulder, Colorado.