5832 Northern Lights Dr - Disclosures/Final Energy - 06/24/2014
Registry ID: 608632682 Rating Number: 32179 Certified Energy Rater: Tyler Stein Rating Date: 06/24/14 Rating Ordered For: Ryland Homes Homeowner Estimated Annual Energy Cost Confirmed Use MMBtu Cost Percent Heating 80.0 $562 31% Cooling 0 $0 0% Hot Water 25.0 $162 9% Lights/Appliances 33.3 $877 49% Photovoltaics -0.0 $-0 -0% Service Charges $204 11 % Total 140.2 $1805 100% This home meets or exceeds the minimum criteria for all of the following: EPA ENERGY STAR Version 3 Home 2004 International Energy Conservation Code 2006 International Energy Conservation Code 2009 International Energy Conservation Code 2012 International Energy Conservation Code energyitgglr wto-�v�.4 racvr6rlagl�,corsr Uniform Energy Rating System ��Q(J5(4wg Ra&v Ryland Homes Vv 5832 Northern Lights Dr Ft Collins, CO 80528 ***W. a �'+ 5 Stars Plus Confirmed Energy Efficient 1 Star 1 Star Plus 2 Stars 2 Stars Plus 3 Stars 3 Stars Plus 4 Stars 4 Stars Plus 5 Stars 5 Stars Plus 500-401 1 400-301 300-251 250-201 200-161 150-101 100-91 90-86 85-71 70 or Less HERS Index: GeneralInfof Conditioned Area: 4630sq. ft. HouseType: Single-family detached Conditioned Volume: 43130 cubic ft. Foundation: Conditioned basement Bedrooms: 5 Mechanical Systems Features Heating: Fuel -fired air distribution, Natural gas, 92.1 AFUE. Water Heating: Conventional, Natural gas, 0.62 EF, 48.0 Gal. Heating: Fuel -fired air distribution, Natural gas, 92.1 AFUE. Duct Leakage to Outside: 39.00 CFM25. Ventilation System: Exhaust Only: 91 cfm, 15.0 watts. Programmable Thermostat: Heating: Yes Cooling: Yes Building SheII Features -( Ceiling Flat: R-38.0 Slab: R-0.0 Edge, R-0.0 Under Sealed Attic: NA Exposed Floor: R-50.4 Vaulted Ceiling: NA Window Type: U-Value: 0.340. SHGC: 0.280 Above Grade Walls: R-23.0 Infiltration Rate: Htg: 1585 Clg: 1585 CFM50 Foundation Walls: R-11.0 Method: Blower door test '„MortiMCj.'M Qner -~yLogic ' ZNo �IEeEAe9l analysis. insight, answers. men W10 FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Date: June 24, 2014 Rating No.: 32179 Building Name: Ryland Homes Rating Org.: EnergyLogic, Inc Owner's Name: Ryland Homes Homeowner Phone No.: (970) 556-0839 Property: 5832 Northern Lights Dr Rater's Name: Tyler Stein Address: Ft Collins, CO80528 Rater'sNo.: 9951760 Builder's Name: Ryland Homes Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 5832 Northern Lights Dr - Ryland - REM14-5.blg Rating Date: 06/24/14 Annual Energy Cost ($) FC 2012 As Designed Heating: 779 658 Cooling: 141 72 Water Heating: 162 162 SubTotal - Used to Determine Compliance: 1082 891 Lights &Appliances: 898 877 Photovoltaics: -0 -0 Service Charge: 204 204 Total: 2184 1972 Mandatory Requirements: Duct Insulation R-Value Check (per Section 405.2) Minimum Duct Insulation (Design must be equal or higher) 6.0 8.0 Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.400 0.340 Home Infiltration (Section 402.4.2): PASSES Duct Leakage (Section 403.2.2): PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 17.6%. Name: Tyler Stein Signature: Organization: EnergyLogic, Inc Date: June 2014 REM/Rate - Residential Energy Analysis and Rating Software v14.5 This information does not constitute any warranty of energy cost or savings. ©1985-2014 Architectural Energy Corporation, Boulder, Colorado. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Ryland Homes Page 2 * Design energy cost is based on the following systems: Heating: Fuel -fired air distribution, 56.0 kBtuh, 92.1 AFUE. Water Heating: Conventional, Gas, 0.62 EF. Heating: Fuel -fired air distribution, 56.0 kBtuh, 92.1 AFUE. Cooling:Air conditioner, 18.0 kBtuh, 13.0 SEER. Window -to -Floor Area Ratio: 0.11 Blower door test: Htg: 1585 Cig: 1585 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software v14.5 This information does not constitute any warranty of energy cost or savings. © 1985-2014Architectural Energy Corporation, Boulder, Colorado.