HomeMy WebLinkAbout2503 Iowa Dr - Disclosures/Blower Door Test - 06/16/2014p {� l LS`ery e_s Date of Test: 6/16/2014 Customer: Bartran Homes Fort Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: BUILDING LEAKAGE TEST GS Services 2000 S. College Ave suite 308 Fort Collins, CO 80525 Test File: Bartran 2503 Iowa BD Technician: Paul Higman Project Number: Building Address: 2503 Iowa Fort Collins, CO 80525 1487 CFM50 (+/- 2.6 %) 2.49 ACH50 81.8 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 99.5 (+/-18.3 %) Exponent (n) = 0.691 ( +/- 0.051 ) Correlation Coefficient = 0.99733 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 84.0 CFM 0.14 ACH 2. Estimated Design Infiltration Rate: Winter: 135.5 CFM Summer: 89.9 CFM 0.23 ACH 0.15 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Digitally signed by: Paul PadHigman 'DN:/CN = Paul H i g m a n/Higman C= US ,/ Date. 2014.06.23 15.18:28-06-00- GS'Seryices „�----- BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 6/16/2014 Test File: Bartran 2503 Iowa BD Building Information Volume 36777 Surface Area Floor Area 3667 Height 18 # of Bedrooms 4 # of Occupants Year of Construction 2014 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 19028-6 9/10/2009 . � ,- =��, G�1G2S gUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 6/16/2014 Test File: Bartran 2503 lowa BD Depressurization Test: Environmental Data Indoor Temperature(A°F) Outdoor Temperature(A°F) Altitude(ft) 78.0 88.0 5000.0 Data Points Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -2.8 n/a n!a -62.8 -60.3 77.9 1589 1691 -0.1 Ring A -57.6 -55.0 68.6 1494 1589 0.0 Ring A -49.7 -47.2 57.1 1366 1453 1.8 Ring A -45.5 -43.0 45.0 1217 1294 -3.4 Ring A -37.4 -34.9 35.3 1081 1150 -0.9 Ring A -31.8 -29.3 30.3 1004 1068 3.9 Ring A -28.0 -25.5 220.4 879 935 0.2 Ring B -19.7 -17.1 122.8 658 700 -1.4 Ring B -2.3 n/a n/a TimeAveraging Period: 0 Deviations from Standard RESNET Multi-Point Test-Test Parameters None ' f . J_ �j� '1 G�Iy1Ce5 gUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 6/16/2014 Test File: Bartran 2503 lowa BD Comments House WRT Garage east=-45.3pa House WRT Garage north =-47.5 pa