Loading...
HomeMy WebLinkAbout2226 Bar Harbor Dr - Disclosures/Blower Door Test - 05/31/2014BUILDING LEAKAGE TEST s Date of Test: 5/31 /2014 Customer: Journey Homes 7251 W 20th Street L-200 Greeley, CO 80634 Phone: 970-449-1612 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: 5. Accuracy Level GS Services 2000 S. College Ave #308 Fort Collins, Co 80525 Test File: Journey Homes 2226 Bar Harbor -BD Technician: Paul Higman Project Number: Building Address: 2226 Bar Harbor Ln Fort Collins, CO 80525 1514 CFM50 (+/- 2.0 %) 3.64 ACH50 83.3 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 151.4 (+/- 14.2 %) Exponent (n) = 0.589 ( +/- 0.039 ) Correlation Coefficient = 0.99721 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 85.6 CFM 0.21 ACH 2. Estimated Design Infiltration Rate: Winter: 138.0 CFM Summer: 91.6 CFM 0.33 ACH 0.22 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Pau I Digitally signed by: Faul Higman f, DN:/CN = Paul H ig mq-n, igman C = US �,,q?e: 2014.06.03 13: �. 25:48-06'00' No Text No Text No Text