HomeMy WebLinkAbout2226 Bar Harbor Dr - Disclosures/Blower Door Test - 05/31/2014BUILDING LEAKAGE TEST
s
Date of Test: 5/31 /2014
Customer: Journey Homes
7251 W 20th Street
L-200
Greeley, CO 80634
Phone: 970-449-1612
Test Results
1. Airflow at 50 Pascals:
(50 Pa = 0.2 w.c.)
2. Leakage Area:
3. Building Leakage Curve:
4. Test Settings:
5. Accuracy Level
GS Services
2000 S. College Ave #308
Fort Collins, Co 80525
Test File: Journey Homes 2226 Bar Harbor -BD
Technician: Paul Higman
Project Number:
Building Address: 2226 Bar Harbor Ln
Fort Collins, CO 80525
1514 CFM50 (+/- 2.0 %)
3.64 ACH50
83.3 in2 LBL ELA @ 4 Pa
Flow Coefficient (C) = 151.4 (+/- 14.2 %)
Exponent (n) = 0.589 ( +/- 0.039 )
Correlation Coefficient = 0.99721
Test Standard: RESNET Multi -Point Test
Test Mode: Depressurization
Standard Level of Accuracy Test
Infiltration Estimates
1. Estimated Average Annual Infiltration Rate: 85.6 CFM
0.21 ACH
2. Estimated Design Infiltration Rate: Winter: 138.0 CFM Summer: 91.6 CFM
0.33 ACH 0.22 ACH
Cost Estimates
1. Estimated Cost of Air Leakage for Heating:
2. Estimated Cost of Air Leakage for Cooling:
Pau I Digitally signed by:
Faul Higman
f, DN:/CN = Paul
H ig mq-n, igman C = US
�,,q?e: 2014.06.03 13:
�. 25:48-06'00'