Loading...
HomeMy WebLinkAbout420 Cajetan St - Disclosures/Final Energy - 09/23/2014A f 4' 7'?� �r1�,p ` S r ices— Property Organization FR Development GS Services - 420 Cajatan (970)449-1612 Fort Collins, CO 80525 Paul Higman Weather:Ft. Collins, CO Builder 420 Cajatan FR Develeopment FR Development 420 Cajatan Annual Energy Cost Styr 2012 IECC As Designed :'Heating,435 441 Cooling 105 90;; Water Heating,° 120 123i SubTotal' Used 660 654; .to�Determine`Compliance Lightis ft Appliances r • .:. 737 `736 Photovoltaics' t 1 O oe Service Charge 240 240 Total 1637 1630`+ ..tea. n .... .. ...... a.G .. .y.. . .. ... ...A...L Mandatory Requirements Window U Factor Check'(Sectibn:402 5) , , Wmdoiv U=Factor (Design must be equal`or lower) 0 480 0 348' 'Home Infiltration (Section 402 4.1 2) PASSES't Duck LeakageL{Section 403 2 2) ': PASSES: Mechamcal,Ventitatlon (Section d03 5) PASSES? This home MEETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code based on a climate zone of 5B. In fact, this home surpasses the requirements by 1.0%. Digitally signed an Paul DN:CNl Paul u DN' CN =Paul Name Paul Higman Signature ' 'lgma'n'Daa:2014: 9S Organization GS Services Date 23 September 2014 %{ 23%j13:09:32 - 0600' Mechanical Systems In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REWDesign - Residential Energy Analysis Software v14.4.1 This information does not constitute any warranty of energy cost or savings. O 1985-2014 Architectural Energy Corporation, Boulder, Colorado. Fort Collins Planning, Development & Transportation Services Community Development & Neighborhood Services Simulated Performance Alternative (SPA) Cover Sheet Submittal and Rating Type Otock Plan Permit — Projected Worst -Case Rating ❑Lot -specific Permit - Projected Rating ❑✓ Completed Home — Confirmed Rating Data Required for All SPA Ratings Builder: FIR Development Energy rater: Paul Higman Builder Model: Address: Address: 420 Cajatan Rating Firm: GS Services Date: 9-18-14 Duct Location Inputs Location Su I Return o /o Area R-Value o /o Area R-Value All within conditioned space 100 0 100 0 Utility Rates Energy Source Service charge Rate Electricity 5 $/month 0.10 $/kWh Natural gas 15 $/month 0.60 $/therm Spaces considered outside the thermal boundary: Additional Information for Stock Plan Permit — Projected Worst -Case Rating 'Worst -case" configuration: Foundation Options included Orientation of front elevation eAttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report Attach REM/Rate Energy Code Inspection Checklist Additional Information for Lot -Specific Permit — Projected Rating 13 ttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report ttach REM/Rate Energy Code Inspection Checklist Additional Information for Completed Home — Confirmed Rating ❑✓ Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report Utility rates reflected in this report must be City -approved rates on lot -specific permit application date.) Attach Home Energy Rating Certificate .... .-1--1111— ,n -