HomeMy WebLinkAbout420 Cajetan St - Disclosures/Final Energy - 09/23/2014A
f
4' 7'?� �r1�,p
` S r ices—
Property Organization
FR Development GS Services
-
420 Cajatan (970)449-1612
Fort Collins, CO 80525 Paul Higman
Weather:Ft. Collins, CO Builder
420 Cajatan FR Develeopment
FR Development 420 Cajatan
Annual Energy Cost
Styr
2012 IECC
As Designed
:'Heating,435
441
Cooling
105
90;;
Water Heating,°
120
123i
SubTotal' Used
660
654;
.to�Determine`Compliance
Lightis ft Appliances r • .:.
737
`736
Photovoltaics'
t
1 O oe
Service Charge
240
240
Total
1637
1630`+
..tea.
n .... .. ...... a.G .. .y..
. .. ... ...A...L
Mandatory Requirements
Window U Factor Check'(Sectibn:402 5) , ,
Wmdoiv U=Factor (Design must be equal`or lower)
0 480
0 348'
'Home Infiltration (Section 402 4.1 2)
PASSES't
Duck LeakageL{Section 403 2 2) ':
PASSES:
Mechamcal,Ventitatlon (Section d03 5)
PASSES?
This home MEETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code
based on a climate zone of 5B. In fact, this home surpasses the requirements by 1.0%. Digitally signed
an
Paul DN:CNl Paul
u DN' CN =Paul
Name Paul Higman Signature ' 'lgma'n'Daa:2014: 9S
Organization GS Services Date 23 September 2014 %{ 23%j13:09:32 -
0600'
Mechanical Systems
In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to
calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the
design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained
periodically to ensure the compliance calculations reflect current federal minimum standards.
REWDesign - Residential Energy Analysis Software v14.4.1
This information does not constitute any warranty of energy cost or savings.
O 1985-2014 Architectural Energy Corporation, Boulder, Colorado.
Fort Collins
Planning, Development & Transportation Services
Community Development & Neighborhood Services
Simulated Performance Alternative (SPA) Cover Sheet
Submittal and Rating Type
Otock Plan Permit — Projected Worst -Case Rating
❑Lot -specific Permit - Projected Rating
❑✓ Completed Home — Confirmed Rating
Data Required for All SPA Ratings
Builder: FIR Development
Energy rater: Paul Higman
Builder Model:
Address:
Address: 420 Cajatan
Rating Firm:
GS Services
Date: 9-18-14
Duct Location Inputs
Location
Su I
Return
o
/o Area
R-Value
o
/o Area
R-Value
All within conditioned space
100
0
100
0
Utility Rates
Energy Source
Service charge
Rate
Electricity
5 $/month
0.10 $/kWh
Natural gas
15 $/month
0.60 $/therm
Spaces considered outside the thermal boundary:
Additional Information for Stock Plan Permit — Projected Worst -Case Rating
'Worst -case" configuration:
Foundation
Options included
Orientation of front elevation
eAttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report
Attach REM/Rate Energy Code Inspection Checklist
Additional Information for Lot -Specific Permit — Projected Rating
13 ttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report
ttach REM/Rate Energy Code Inspection Checklist
Additional Information for Completed Home — Confirmed Rating
❑✓ Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report
Utility rates reflected in this report must be City -approved rates on lot -specific permit application date.)
Attach Home Energy Rating Certificate