Loading...
HomeMy WebLinkAbout1020 Trading Post Rd - Applications/Single Family New - 04/11/2012Fort Collins COMMUNITY DEVELOPMENT & NEIGHBORHOOD SERVICES 281 N. College Ave. • Fort Collins, CO 80524 • Phone: 970-416-2740 www.fcgov.com/building BUILDING PERMIT APPLICATION Job Site Address PROPERTY OWNER IN Last name D. R. HORTONI INC. First Name Middle Street Address 9555 S. KINGSTON CT., SUITE 200 city ENGLEWOOD State CO Zip 80112 CONTRACTOR INFO: Company Name D. R. HORTON, INC. Contractor Phone # 303-488-0061 Lic Holder Name JOSHUA VICARS - It is not optional) Phone # 303-488-0061 City of Fort Collins License # D-590 Supervisor Cert # 3035-D 1 Mailing Address 9555 S. KINGSTON CT., SUITE 200 City ENGLEWOOD LEGAL INFO: State CO Zip 80112 Subdivision/PUDTRAIL HEAD Filing # Lot #� Block # Lot Sq Ft J� CONSTRUCTION INFO: Total Building Sq Ft (not including basement) 9� Total Garage Sq Ft 4190 Residential Sq Ft /T49% Comm'I Sq Ft — /1 # of Stories-2— Bldg Height qt Ill # Dwelling Units r/l 161 Floor Sq Ft lffi'?2nd Floor Sq Ft I `%L� 31d Floor Sq Ft I Unfiished Bsmt Sq Ft /000 Finished Bsmt Sq Ft Y # of Bedrooms # of Full Baths '/, Baths '/2 Baths __L # of Fireplaces Air Conditioning:• YeENNo� Energy info:( Circle appropriate choice) 1.ComCheck11 2. ResC heck w/Air Sealing 3. ResCheck w/Blower Door ❑4. Simulated Performance Alternative 6. Prescriptive w/Air Sealing 6. Prescriptive w/ Blower Door City of Fort Collins Stock Plan # l]f'li f ' (N �j List appropriate option #s 7, (J 1 4 UTILITIES INFO: Water Tap Size 3/4" Sewer Tap Size 4" Metered: Yes W1No� Temp. Pedestal Yes ✓❑ No Type of Heat: Gas nElectric Electric Main Breaker Size (Residential only) 1150 Amp or Less � 200 Amp Other Value of Construction (including labor, mmaterial & profit) $ U 1 1 1 00 ) • 0 ��/� /� /� Description of Work: QNl �l ��IY A 1 Li)r�2laet Io ktmi I0 rwm/ AI C, Contact Name & Phone # of JOBSITE SUPERVISOR: SHANE SENA 303-720-4616 Subcontractor Info: Electrical —EC], INC. Framer K & L Solar Mechanical FOUR SEASONS - COBB Plumbing JOHNSON & SONS Roofing CAMPBELL BEARD Concrete FALCON CONCRETE Fireplace AMI Other Other Other Applicant: I hereby acknowledge that I have read this application and state that the above information is correct and agree to comply with all requirements contained herein and City F rt Collllliins)ord''[�'/a�n-ces and state laws regulating building construction. Applicant Signature V Un Print NameGINA CRESPIN Phone 303-754-3223 Distribution: White — Office Yellow —Applicant - Pink — VVVVW/Stormwater THIS APPLICATION EXPIRES 180 DAYS FROM APPLICATION DATE 2005 FORT C9.LINS&ESIDENTIIIIAL CODE COMPLIANCE FORM updated 3-18- 05 DIRECTIONS: Place a check next to P poslow. rlptive, UA, or SPA indicating the path chosen. Next, circle the method within that path you intend to If choosing prescriptive or UA, the applicant must also rhnncn hafiunan an Air cnalinn rharklict nr Rlnwar nnnr Tact (A)PRESCRIPTIVE compliance for house with natural gas heating and wood framing, N1111.1 Insulation R- value Standard HVAC equipment, 80% AFUE High efficiency HVAC equipment 90% AFUE Method 1 2x6 Walls Method 2 2x4 Walls Method 3 2x6 Walls Method 4 2x4 Walls Exterior walls above grade frame 18 - 38 19 13/10 30 15 3 38 19 13110 30 18 - 38 19 - 1 19 15 - 38 19 13/10 1 19 Exterior insulated sheathing Ceiling/attic Crawls ace walls Basement walls frame/continous Floor over un-cond space AL UA ALTERNATIVE, (REScheck) SECTION N1111.5 RESc heck must show a passing score of 10% better than code minimum. Submit calculations demonstrating equivalency to one of the prescriptive methods above. The rating must be submitted at time of application and must include Address of residence; Name of individual completing the rating form; Name & version of software tool. Air Sealinq Checklist or Blower Door Test is required. Circle one: Air Sealing Checklist Blower Door Test (C)SIMULATED PERFORMANCE ALTERNATIVE, SECTION N1113 Current accredited programs`. S-star of Colorado,)Energy Smiths, Builtwright HERS accredited energy rating system. List company/program. Must submit score of 84 minimum. A preliminary rating must be submitted at time of application and must include Address of residence; Name of individual completing the rating/compliance form; Name & version of software tool. Final rating requires a blower door test. SIGN: {ll4-) DATE: CONTRA OR: I '{, f+Urj PHONE:' Residential Compliance Guide — pg 10