HomeMy WebLinkAbout2333 Strawfork Dr - Disclosures/Final Energy - 07/15/2014Fort Collins Energy Cost Compliance
- Non Electric Heat
Property Organization GS Services
Bartran Consrtuctio GS Services
2333 Strawfork P1 970-449-1612
Ft. Collins, CO 80525 Paul Higman
Weather:Ft. Collins, CO Builder
2333 Strawfork Bartran Construction
Bartran Homes 2333 Strawfork
Annual Energy Cost $/yr
FC 2012
As Designed
Heating
480
482
Cooling
211
135
Water Heating
153
154
SubTotal - Used to Determine Compliance
843
772
Lights & Appliances
1156
1151
Photovoltaics
-0
-0
Service Charge
240
240
Total
2239
2163
Mandatory Requirements
Window U-Factor Check (Section 402.5)
Window U-Factor (Design must be equal or lower) 0.400 0.350
Home Infiltration (Section 402.4.2) PASSES
Duct Leakage (Section 403.2.2) PASSES
This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code,
amended by the City of Fort Collins. In fact, this home surpasses the requirements by 8.5%.
Name Paul Higman
Organization GS Services
Mechanical Systems
Heating
Water Heating
Cooling
Window -to -Floor Area Ratio:
Blower door test
Signature
Date 1 15 July 2014
Fuel -fired air distribution, 108.0 kBtuh, 95.0 AFUE.
Conventional, Gas, 0.58 EF.
Air conditioner, 21.5 kBtuh, 13.0 SEER.
0.11
Htg: 1377 Clg: 1377 CFM50
In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to
calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the
design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained
periodically to ensure the compliance calculations reflect current federal minimum standards.
REM/Design - Residential Energy Analysis Software v14.4.1
This information does not constitute any warranty of energy cost or savings.
0 1985-2014 Architectural Energy Corporation, Boulder, Colorado.
Fort Collins
Planning, Development & Transportation Services
Community Development & Neighborhood Services
Simulated Performance Alternative (SPA) Cover Sheet
Submittal and Rating Type
❑Stock Plan Permit — Projected Worst -Case Rating
Lot -specific Permit - Projected Rating
❑� Completed Home — Confirmed Rating
Data Required for All SPA Ratings
Builder: Bartran Homes
Energy rater Paul Higman
Builder Model
Address
Address: 2333 Strawfork -DV
Rating Firm: GS Services
Date: 6-11-14
Duct Location Inputs
Location
SuRply
Return
% Area
I R-Value
% Area
R-Value
All within conditioned space
100
0
100
0
Utility Rates
Energy Source
Service charge
I Rate
Electricity
5 $/month
0.10 $/kWh
Natural gas
15 $/month
0.60 $/therm
Spaces considered outside the thermal boundary:
Additional Information for Stock Plan Permit — Projected Worst -Case Rating
"Worst -case" configuration:
Foundation type(s)
Options included
Orientation of front elevation
BAttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report
Attach REM/Rate Energy Code Inspection Checklist
Additional Information for Lot -Specific Permit — Projected Rating
Rttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report
ttach REM/Rate Energy Code Inspection Checklist
Additional Information for Completed Home — Confirmed Rating
FZ]Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report
(Utility rates reflected in this report must be City -approved rates on lot -specific permit application date.)
Attach Home Energy Rating Certificate
Updated 11/09/2012