Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
722 W Mountain Ave - Applications/Addition or Alteration - 01/17/2012
Cityot COMMUNITY DEVELOPMENT & NEIGHBORHOOD SERVICES FOI t Collins 281 N. College Ave. • Fort Collins, CO 80524 • Phone: 970-416-2740 / www.fcgov.com/building BUILDING PERMIT APPLICATION APPLICATION NUMBER 1 , I �)1 3,I) i 2�1 APPLICATION DATE i III I Job Site Address I'M W. fAov*j`iV1N/ 1041e, Unit # PROPERTY OWNER INFO: (All owner information is required - it is not optional) Phone # (014 'boo 4i'9g3 L" R"t�i Last name OAVt� S First Name �RT + G V Middle Street Address rj21 W P�JVNTAIA/ AVtfi City F-r. c4w *4 State GO zipy0stil CONTRACTOR INFO: Company Name aLN / 13v1Lt*.Aa Contractor Phone # Lic Holder Name Mailing City of Fort Collins License # Supervisor Cart # City State Zip Subdivision/PUD Ira G MI6 Filing # Lot #_3L__ Block #'41 Lot Sq Ft SS15 CONSTRUCTION INFO: Total Building Sq Ft (not including basement) (Q-13 Total Garage Sq Ft 7 QA Residential Sq Ft 31154r Comm'I Sq Ft # of Stories Z- Bldg Height uO1 # Dwelling Units ) 1 °' Floor Sq Ft _ �� 2n° Floor Sq Ft ��'S 3m Floor Sq Ft Unf ished Bsmt Sq Ft Finished Bsmt Sq Ft 9l'F # of Bedrooms 4# of Full Baths 2 % Baths Z- Y Baths # of Fireplaces Air Conditioning: Ye4ol jj'''�� l Energy info: ( Circle appropriate choice) 1. ComCheck11 2. ResCheck w/Air Sealing ❑ 3. ResCheck w/Blower Door I,L�J1I4. Simulated Performance Alternative❑ 5. Prescriptive w/Air Sealing 11 6. Prescriptive w/ Blower Door City of Fort Collins Stock Plan # List appropriate option #s 11 OI UTILITIES INFO: Water Tap Size Sewer Tap Size Metered: Yes ©No❑ Temp. Pedestal Yes❑ No ❑ 1 U Type of Heat: © Gas ❑Electric Electric Main Breaker Size (Residential only) Ell 50 Amp or Less ❑ 200 Amp DOther Value of Construction (including labor, material & profit) $ Description of Attu l43 sbyG"_TO MAS;t VL' 880Ri00M ow VRsi tvty Sowwo VwofL RC L-0 C.IP'(a` W r►�gF t-wo % 4&06 if'l Pt -Di Contact Name & Phone # of JOBSITE SUPERVISOR: (I1')WK-r b PAS 61 q .1A0 -4i443 Electrical Mechanical Framer Roofing Concrete. Solar Other Other Plumbing Fireplace Other Applicant: I hereby acknowledge that I have read this application and state that the above information is correct and agree to comply with all requirements contained herein and City of F Collin ordinances and state laws regulating buildin cons ruction. Applicant Signature Print Name PA 9 '1000 O Distribution: White -Office Yellow -Applicant Pink - VWAN/Stomwater 0441 THIS APPLICATION EXPIRES 180 DAYS FROM APPLICATION DATE CIt of Planning, Development & Transportation Services Fort Collins Community Development & Neighborhood Services 281 North College Avenue �f Fort Collins, CO 80524 970.416.2740 Building Permit Application Submittal Requirements for New Single Family Residential Construction (Sr Additions) (Revised 12-3-2010) The items listed below shall be included in all new requests for building permit. Please initial in front of the item indicating that it is included in the submittal. Only complete submittals will be reviewed. Current adopted code is 2009 IRC. Initial Required Item Building Permit Application — Three-part form to be completed by applicant. Plan Check Fee - (See www.fcgov.com or obtain Fee Schedule at B & Z counter) Two copies of everything listed below. For Building review. -Additional 3rd set if building is over 50 years old or older For Historical review ,Site Plans - Architectural site plan, drawn to scale on 8 1/2"x11" sheet showing the location of the building relative to property lines and other structures on the lot. Architectural Drawings - Architectural drawings showing all floor plans, elevations, stair section, .building section, and wall section detailing all construction components used. Drawings must be drawn to scale such as 1/4"= V-0". Structural Drawings (floor framing & roof framing) —Structural documents bearing an original seal and signature of an architect or engineer registered in the State of Colorado. Structural drawings, shall include all beams, floorsystem, roof system, spans, posts, columns, hangers and connections, and locate and identify all point loads. Plans shall verify that the design meets the following criteria: Wind load=100 MPH exposure B, 30-LB roof/snow live load and 15-LB dead load. Wall Brace Design — Plan showing "Brace Wall" locations and method of construction. If the house does not meet the prescriptive brace requirements of 2009 IRC section R602.10, engineered design bearing a seal and signature of an architect or engineer registered in the State of Colorado is required. Engineered Foundation — Foundation documents bearing an original seal and signature of an architect or engineer registered in the State of Colorado. The design requirements shall be for a 30" N frost dept, seismic zone (1) and 30-LB snow load. Identify wet or damp-proof requirements. Identify and size subsurface drainage system. Energy Code - (Two Copies) Submit the Fort Collins Energy Code Compliance Form. If SPA method is selected, preliminary rating must be submitted also. Additions must comply wi h Dtesciiotive energy code, see the Fort Collins Energy Compliance Form. HVAC sizing & load calculations - (Two Copies) Code section M1401.3 requires the HVAC system be designed based on loads calculated from ACCA manual J, 81" or current edition. Duct sizing must be include signed_per ACCA manual D. See local amendment N1101.1 for Thermal Design Parameters.<Not required for additions Other - Include construction, utility, value of construction, description of work and subcontractor._ information. Applications must be signed by the applicant and must include a daytime phone number. Grading Plan may be required if new impervious area is over 350 sq ft. Contact Stormwater Development Review at 970-221-6700 for more information. Applicant Name Telephone Number Job Site Address 0012002151