INSULATION DISCLOSURE FORM
inscisaxts - 7n0198
Job address:
General contractor:
Insulation contractor:
' � ank
Neighborhood & Building Services
281 N. College Ave., P.O. Box 580, Fort Collins, CO 80522
Phone: 970 2216760 FAX: 970 224 6134
INSTRUCTIONS
This disclosure form is to be signed by the insulation contractor or representative of the general contractor.
Please type or print, except for the signature. Complete the information in the appropriate spaces provided.
If components vary, make multiple entries to describe them.
One copy of this form must be provided to the Building and Zoning Department prior to the C.O.
One copy of this form must be made available to the original home buyer.
Instilatioril,,
_
Location
Materials
Thickness
Rated
R-value
Location
Int / ext
Notes
Flat or vaulted ceilings
with attics above
Loose Fall Fiberglass
j.3
_K-�3p;
Ceilings with enclosed
rafter cavities
ACqI
/
Frame walls and rlm/band
joists — to exterior
ame walls and rim/band
joists — to attic, garage
Fohprpinss Batts
5a.
Frame Floor - cantilever
F*hprgl;iqq Batts
Blow -in -Blanket
a
Frame floor - over garage or
crawl space
Fiberglass Batts
Slab -on -grade (0-12")
Crawl space walls
Foberglass Roll
Basement walls
Fiberglass Batts
Certltioatlon;, .
I/We certify that the above -listed insulation was installed in the building at the above locations in conformance with the current requirements of the
Fort Collins Residential Energy Code, and that it was installed in accordance with the "Insulation Guidelines" published by the City of Fort Collins.
Person Certifying Job:
Business Finn: L & L Insulation. LLC
Address: 401 N I ink Lane Fort Cnllins CO 80524
Date:
Phone: 970-221-3180
Jet Stream"' Ultra Blowing Insulation
%ttic and Cavity Wall Card
Batts and Blankets
When installed in accordance with the manufacturer's
recommendations, Knauf Insulation baits and blankets will
provide the full R-value.
R-Value*
Minimum Thickness
:• "To obEain'an
insulation resistance
(R•Value) of:
Installed insulation should
not be less than:
R49
13.75"
R-38HD
10.25"
R-38
12.00"
R-30HD
8.25"
R-30
10.00,
R-26
1 9.00,
R-22
6.50"
R-21HD
5.50,
R-19
6.25""
R-15HD
3.50"
R-13
3.50'
R-11
3.50"
R-8
2.50"
" R-18 in a 5.5' cavity. Confirms to ASTM C 665 and Federal
Specf"ton HH4521F.
Framing Adjustment
To compensate for framing members, the number of bags per
1,000 sq. ft. of area to be insulated should be as shown below.
:xe
Joist 16" 1 D.C.
Dimensions Framing Framing
2x4 29.2 1 29.4
-60 2x6 28.9 1 29.1
2x8 1 28.6 1 28.9
2x4
23.0
23.2
R49
2x6
22.7
22.9
2x8
22.4
22.7
2x4
20.4
20.6
R-44
2x6
20.1
20.3
2x8
19.8
20.1
2x4
17.3
17.4
R-38
2x6
17.0
17.2
2x8
16.7
17.0
2x4
13.2
13.3
R-30
2x6
12.9
13.1
2x8
12.6
12.9
2x4
11.3
11.4
R-26
2x6
11.0
11.2
2x8
10.8
11.0
2x4
9.3
9.5
R-22
2x6
9.1
9.3
2x8
8.8
9.1
2x4
7.9
8.1
R-19
2x6
7.7
7.9
2x8
7.4
7.7
2x4
5.3
5.4
R-13
2x6
5.0
5.2
2x8
4.8
5.0
2x4
4.3
4.4
R-11
2x6
4.1
4.3
2x8
3.8
4.1
Ieeee�exl�.w
REENGUARD'
IndoorAir Quality Certified
Knead Insulation Jet Stream -Ultra is carolled for index air quality as
a low emitting product by The GREENGUARD Environmental Institute
in both the GREENGUARD Indoor Air Quality Certification Program -
and the more stringent GREENGUARD Children a Schools standard
andisverifiedtubeformaidehydetes. wrw.greenguard.org
IN,',[
if1 4ime 1-0 .rave eJ1er
(A/
Equipment Required
It is recommended that a pneumatic bowing machine and a corrugated hose with a minimum W internal corrugation, a minimum length
of 159. Coils in the hose should not be less than 36' in diameter. Acceptable material feed rate is 5-35lbslminute. Recommended feed
rate is 15-25 has/minute.
Thermal Performance (Sidewall and Attic Application)
The stated thermal resistance (R-value) is provided by installing in accordance with the manufacturer's instructions. Failure to install the
required number of bags per 1,000 square feet and exceeding the maximum square feet of coverage per bag as recommended by the label
will result in lower installed R-values. Feld blending of this product with other loose fig insulations is not recommended by the manufacturer.
' R means resistance to heel flow. The higher the R-value, the greater the mmlagng power. To get the masked R-value, it is essential that this Insulation be installed propady.
Open Attic
y
R-Value
To obtain an insulation
resistance (R-value) of:
Begs/
1,OOO SF
The numberof bags/.:
1,600 SF of netarea -
':should dot be less
- than:
Maximum
Coverage
Contentsofthis
. bag should not
cover
more than:
Minimum
Weight
TheweightlSF
of installed
insulation should not
be less than
Initial
Installed '
Thickness
Installed insulation
should not be less
- than:
Minimum`Settled
Thickness"
Contents of this
bag should
not cove: more
than:
R-60
29.7
33.6 SF
.952lbs.
19.750'
19.750'
R49
23.5
42.5 SF
.753lbs.
16.375'
16.375'
R-44
20.9
47.8 SF
.670 tbs.
14.875'
14.875"
R-38
17.8
56.2 SF
.569 tbs.
13.000"
13.000'
R-30
13.6
73.3 SF
.437 tbs.
10.375"
10.375'
R-26
11.8
85.0 SF
.377 lbs.
9.125'
9.125"
R-22
9.8
102.2 SF
.313 tbs.
7.750'
7.750"
R-19
8.4
119.3 SF
.2681bs.
6.750'
6.750'
R-13
5.7
175.3 SF
.183 lbs.
4.750"
4.750"
R-11
4.7
210.8 SF
.152lbs.
4.000-
4.000'
Bap Net WeighF-Nmind 32 M., MNimum 31 M
Cmwglemd betdebn date nee dtlenv,ed mop a WleMek• II bbanprtshne b Mtl ga aeh 13' gteagnNp, 20 pal air prenwe and 15a d T btenerymmpebdhoee
Tlrvpmhetonlon be,epMmrmrmwpeenenb dASTNCTSI, Type I, edmwfeA Fetid Spedkd.H"ILVB,Type I,C ER- .debnuredh ecadmmwNCHIendC51a
' Td'rmme reebtrm bhml Oow The hipAe MRMe, M pmMM indeFp paver. Togd M rred,ed R-wbe, h b eeembdtlwt Nb nedadm b'embbd pragdy. tiyw doe ywr.er, IletbeNP
erne mtl hlox hen melWy.lmeuethr,e dondarordh Nie peekepn
"Bawd m Thvd Perry 2ywreeninp away, Nopredidel eeeknw,taverealyen PeMdnwld be 1 pewnt a tern TAb enountdedanp le Nerwly vnip,ifieer,t Theefee, M MebMdendeeded
mNmmeee coo dlephey M -erne
W ulAmr.'A b e egvbed pedensF d Un'mi
Builder's Insulation Statement
Jet Stream Ultra has been installed in conformance with the included recommendations to provide a thermal resistance of
Attic Area
R-Value
R-
at
Thickness
Inches
Sloped Ceilings
R-
at
Inches
Walls
R-
at
Inches
Floors (over an unheated crawl space) R-
at
Inches
Crawl Space Perimeter
R-
at
Inches
Date Installed
Blown insulation has been ins ed in conformance with the above recommend�D'ops to provide an R-value of:
R-��_ using bags of this insulation to cover H square feet of area
at mini thickness of J inches.
Insulation Car;iratior signature)
L.
�
,
y a r7i
Company
Date
Hone Builder (signature)
Company
Date