HomeMy WebLinkAbout1208 Bateleur Ln - Disclosures/Insulation - 07/24/2014Fort Collins Residential Energy Code INSULATION DISCLOSURE FORM inscisaxts - 7n0198 Job address: General contractor: Insulation contractor: ' � ank Neighborhood & Building Services 281 N. College Ave., P.O. Box 580, Fort Collins, CO 80522 Phone: 970 2216760 FAX: 970 224 6134 INSTRUCTIONS This disclosure form is to be signed by the insulation contractor or representative of the general contractor. Please type or print, except for the signature. Complete the information in the appropriate spaces provided. If components vary, make multiple entries to describe them. One copy of this form must be provided to the Building and Zoning Department prior to the C.O. One copy of this form must be made available to the original home buyer. Instilatioril,, _ Location Materials Thickness Rated R-value Location Int / ext Notes Flat or vaulted ceilings with attics above Loose Fall Fiberglass j.3 _K-�3p; Ceilings with enclosed rafter cavities ACqI / Frame walls and rlm/band joists — to exterior ame walls and rim/band joists — to attic, garage Fohprpinss Batts 5a. Frame Floor - cantilever F*hprgl;iqq Batts Blow -in -Blanket a Frame floor - over garage or crawl space Fiberglass Batts Slab -on -grade (0-12") Crawl space walls Foberglass Roll Basement walls Fiberglass Batts Certltioatlon;, . I/We certify that the above -listed insulation was installed in the building at the above locations in conformance with the current requirements of the Fort Collins Residential Energy Code, and that it was installed in accordance with the "Insulation Guidelines" published by the City of Fort Collins. Person Certifying Job: Business Finn: L & L Insulation. LLC Address: 401 N I ink Lane Fort Cnllins CO 80524 Date: Phone: 970-221-3180 Jet Stream"' Ultra Blowing Insulation %ttic and Cavity Wall Card Batts and Blankets When installed in accordance with the manufacturer's recommendations, Knauf Insulation baits and blankets will provide the full R-value. R-Value* Minimum Thickness :• "To obEain'an insulation resistance (R•Value) of: Installed insulation should not be less than: R49 13.75" R-38HD 10.25" R-38 12.00" R-30HD 8.25" R-30 10.00, R-26 1 9.00, R-22 6.50" R-21HD 5.50, R-19 6.25"" R-15HD 3.50" R-13 3.50' R-11 3.50" R-8 2.50" " R-18 in a 5.5' cavity. Confirms to ASTM C 665 and Federal Specf"ton HH4521F. Framing Adjustment To compensate for framing members, the number of bags per 1,000 sq. ft. of area to be insulated should be as shown below. :xe Joist 16" 1 D.C. Dimensions Framing Framing 2x4 29.2 1 29.4 -60 2x6 28.9 1 29.1 2x8 1 28.6 1 28.9 2x4 23.0 23.2 R49 2x6 22.7 22.9 2x8 22.4 22.7 2x4 20.4 20.6 R-44 2x6 20.1 20.3 2x8 19.8 20.1 2x4 17.3 17.4 R-38 2x6 17.0 17.2 2x8 16.7 17.0 2x4 13.2 13.3 R-30 2x6 12.9 13.1 2x8 12.6 12.9 2x4 11.3 11.4 R-26 2x6 11.0 11.2 2x8 10.8 11.0 2x4 9.3 9.5 R-22 2x6 9.1 9.3 2x8 8.8 9.1 2x4 7.9 8.1 R-19 2x6 7.7 7.9 2x8 7.4 7.7 2x4 5.3 5.4 R-13 2x6 5.0 5.2 2x8 4.8 5.0 2x4 4.3 4.4 R-11 2x6 4.1 4.3 2x8 3.8 4.1 Ieeee�exl�.w REENGUARD' IndoorAir Quality Certified Knead Insulation Jet Stream -Ultra is carolled for index air quality as a low emitting product by The GREENGUARD Environmental Institute in both the GREENGUARD Indoor Air Quality Certification Program - and the more stringent GREENGUARD Children a Schools standard andisverifiedtubeformaidehydetes. wrw.greenguard.org IN,',[ if1 4ime 1-0 .rave eJ1er (A/ Equipment Required It is recommended that a pneumatic bowing machine and a corrugated hose with a minimum W internal corrugation, a minimum length of 159. Coils in the hose should not be less than 36' in diameter. Acceptable material feed rate is 5-35lbslminute. Recommended feed rate is 15-25 has/minute. Thermal Performance (Sidewall and Attic Application) The stated thermal resistance (R-value) is provided by installing in accordance with the manufacturer's instructions. Failure to install the required number of bags per 1,000 square feet and exceeding the maximum square feet of coverage per bag as recommended by the label will result in lower installed R-values. Feld blending of this product with other loose fig insulations is not recommended by the manufacturer. ' R means resistance to heel flow. The higher the R-value, the greater the mmlagng power. To get the masked R-value, it is essential that this Insulation be installed propady. Open Attic y R-Value To obtain an insulation resistance (R-value) of: Begs/ 1,OOO SF The numberof bags/.: 1,600 SF of netarea - ':should dot be less - than: Maximum Coverage Contentsofthis . bag should not cover more than: Minimum Weight TheweightlSF of installed insulation should not be less than Initial Installed ' Thickness Installed insulation should not be less - than: Minimum`Settled Thickness" Contents of this bag should not cove: more than: R-60 29.7 33.6 SF .952lbs. 19.750' 19.750' R49 23.5 42.5 SF .753lbs. 16.375' 16.375' R-44 20.9 47.8 SF .670 tbs. 14.875' 14.875" R-38 17.8 56.2 SF .569 tbs. 13.000" 13.000' R-30 13.6 73.3 SF .437 tbs. 10.375" 10.375' R-26 11.8 85.0 SF .377 lbs. 9.125' 9.125" R-22 9.8 102.2 SF .313 tbs. 7.750' 7.750" R-19 8.4 119.3 SF .2681bs. 6.750' 6.750' R-13 5.7 175.3 SF .183 lbs. 4.750" 4.750" R-11 4.7 210.8 SF .152lbs. 4.000- 4.000' Bap Net WeighF-Nmind 32 M., MNimum 31 M Cmwglemd betdebn date nee dtlenv,ed mop a WleMek• II bbanprtshne b Mtl ga aeh 13' gteagnNp, 20 pal air prenwe and 15a d T btenerymmpebdhoee Tlrvpmhetonlon be,epMmrmrmwpeenenb dASTNCTSI, Type I, edmwfeA Fetid Spedkd.H"ILVB,Type I,C ER- .debnuredh ecadmmwNCHIendC51a ' Td'rmme reebtrm bhml Oow The hipAe MRMe, M pmMM indeFp paver. Togd M rred,ed R-wbe, h b eeembdtlwt Nb nedadm b'embbd pragdy. tiyw doe ywr.er, IletbeNP erne mtl hlox hen melWy.lmeuethr,e dondarordh Nie peekepn "Bawd m Thvd Perry 2ywreeninp away, Nopredidel eeeknw,taverealyen PeMdnwld be 1 pewnt a tern TAb enountdedanp le Nerwly vnip,ifieer,t Theefee, M MebMdendeeded mNmmeee coo dlephey M -erne W ulAmr.'A b e egvbed pedensF d Un'mi Builder's Insulation Statement Jet Stream Ultra has been installed in conformance with the included recommendations to provide a thermal resistance of Attic Area R-Value R- at Thickness Inches Sloped Ceilings R- at Inches Walls R- at Inches Floors (over an unheated crawl space) R- at Inches Crawl Space Perimeter R- at Inches Date Installed Blown insulation has been ins ed in conformance with the above recommend�D'ops to provide an R-value of: R-��_ using bags of this insulation to cover H square feet of area at mini thickness of J inches. Insulation Car;iratior signature) L. � , y a r7i Company Date Hone Builder (signature) Company Date The coverage information an this AnicrSidewall card applies to the entire United States (including Minnesota). www.knaufinsulation.us Knauf Insulation GmbH One Knauf Drive, Shelbyville, IN 46176 Tel: (800) 825-4434 ext 8300 FAX (317) 398-3675 0 2011 Knauf Insulation GmbH.