Loading...
HomeMy WebLinkAbout381 Osiander St - Disclosures/Final Energy - 07/22/2014Fort Collins Energy Non Electric Heat Property Organization GS Services FR Development GS Services 381 Osiander (970) 449-1612 Fort Collins, CO 80525 Paul Higman Weather:Ft. Collins, CO Builder 381 Osiander FR Develeopment FR Development -381 Annual Energy Cost $/yr FC 2012 As Designed Heating 566 443 Cooling 116 74 Water Heating 117 117 SubTotal - Used to Determine Compliance 800 634 Lights £t Appliances 737 736 Photovoltaics -0 -0 Service Charge 240 240 Total 1777 1610 Mandatory Requirements Duct Insulation R-Value Check (per Section 405.2) Minimum Duct Insulation (Design must be equal or higher) 6.0 8.0 Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or tower) 0.400 0.350 Home Infiltration (Section 402.4.2) PASSES Duct Leakage (Section 403.2.2) PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 20.79L Name Paul Higman Organization GS Services Mechanical Systems Heating Cooling Water Heating Window -to -Floor Area Ratio: Blower door test Signature Date 22 July 2014 Fuel -fired air distribution, 78.0 kBtuh, 92.1 AFUE Air conditioner, 24.0 kBtuh, 13.0 SEER. Conventional, Gas, 0.61 EF. 0.11 Htg: 998 Clg: 998 CFM50 Digitally -signed Paul by: Paul Higman DN: CN = Paul HigmanHigman C= US Date: 2014.07.22 07:14:09-06'00' This information does not constitute any warranty of energy cost or savings. © 1985-2014 Architectural Energy Corporation, Boulder, Colorado. Fort Collins , Energy Non Electric He" Property FR Development 381 Osiander Fort Collins, CO 80525 Weather:Ft. Collins, CO 381 Osiander FR Development -381 Organization GS Services (970) 449-1612 Paul Higman Builder FR Develeopment S` ervc�e In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REWDesign - Residential Energy Analysis Software v14.4.1 This information does not constitute any warranty of energy cost or savings. ©1985-2014 Architectural Energy Corporation, Boulder, Colorado. Page 2 of 2 City of F6rt Collins Planning, Development & Transportation Services Community Development & Neighborhood Services Simulated Performance Alternative (SPA) Cover Sheet Submittal and Rating Type []Stock Plan Permit — Projected Worst -Case Rating ❑Lot -specific Permit - Projected Rating FV]Completed Home — Confirmed Rating Data Required for All SPA Ratings Builder: FIR Development Energy rater Paul Higman Builder Model: Address: Address: 381 Osiander Rating Firm: GS Services Date: 7-11-14 Duct Location Inputs Location Su ply Return % Area R-Value % Area R-Value Within conditioned space 75 0 75 0 25 R-8 25 R-8 Utility Rates Energy Source Service charge Rate Electricity 5 $/month 0.10 $/kWh Natural gas 15 $/month 0.60 $/therm Spaces considered outside the thermal boundary: Additional Information for Stock Plan Permit — Projected Worst -Case Rating "Worst -case" configuration: Foundation Options included Orientation of front elevation [3Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report ttach REM/Rate Energy Code Inspection Checklist Additional Information for Lot -Specific Permit — Projected Rating ttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report ttach REM/Rate Energy Code Inspection Checklist Additional Information for Completed Home — Confirmed Rating ❑✓ Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report -- Utility rates reflected in this report must be City -approved rates on lot -specific permit application date.) L_JAttach Home Energy Rating Certificate