HomeMy WebLinkAbout3409 Buntwing Ln - Applications/Single Family New - 12/22/2011BUILDING PERMITS rC 8052E 0580 - DIVISION
P.O. Box 580 •Fort Collins, CO 80522^0580 • Phone: 221-6760
www.fcgov.com/building
6a&Alm
City of Fort Collins BUILDING PERMIT APPLICATION
APPLICATION NUMBERu I c/ 1 APPLICATION DATE
Job Site Address 3409 Buntwing Lane Unit #
PROPERTY OWNER INFO: (All owner information is required — it is not optional) Phone # 221-4700
Last Name Ausbrooks First Name Mark Middle
Street Address 1943 E: Lincoln Avenue City Fort Collins State CO zip 80524
CONTRACTOR INFO: Company Name KEM Homes Construction Contractor Phone # 663-9430
Lic. Holder Name William R. Krug City of Fort Collins License # B-45 Supervisor Cart # 60
Mailing Address 7352 Greenridge Road, A-6 City Windsor State CO zip 80550
LEGAL INFO:
Subdivision/PUD Hearthfire PUD Filing # 2nd Lot # 12 Block # Lot Sq Ft 16,513
CONSTRUCTION INFO: Total Building Sq Ft (not including basement) 2186 Total Garage Sq Ft
Residential Sq Ft 2186 Comml Sq
ls' Floor Sq Ft 2186
# of Bedrooms 3
Air Conditioning: Yes No
3. ResCheck w/Blower Door
City of Fort Collins Stock Plan #
# of Stories 1 Bldg Height # Dwelling Units 1
2nd Floor Sq Ft N/A Unfinished Bsmt Sq Ft 2170 Finished Bsmt Sq Ft N/A
# of Full Baths 2 % Baths 0 Y: Baths 1 # of Fireplaces 1
fiaq[gy info• mlasi ro riate choic . ComCheck 2. ResCheck w/Air Sealing
IILATED PERFORMANCE ALTERNATIV
4. E-Star w/ o oor 5.�rescripTiv�r Sealing 6. Prescriptive w/Blower Door
6 � �
List appropriate option #s
UTILITIES INFO:
Water Tap Size 3/4" Sewer Tap Size 4" Metered: jsr No Temp. Pedestal: (21IOr No
Type of Heat: El Gas ❑ Electric Electric Main Breaker Size (Residential only): 5a 150 Amp or Less ❑ 200 Amp ❑ Other
2��} 00
Value of Construction (including labor, material & profit) $ " 1-1
Description of Work: New residential home with 3—car garage and unfinished full basement.
Contact Name & Phone # of JOBSITE SUPERVISOR: Bill Gurski 566-3208
Subcontractor Info: FIREPLACE: Quality Energy
Electrical Rossi Electric Mechanical Northern Colorado Air
Framer
Plumbing Colorado Plumbing
Roofing Bob Behrends Concrete Affordable Other_
Applicant: I hereby acknowledge that I have read this application and state that the above information is correct and agree to comply with all requirements
contained herein and City of Fort Collins orrddd' iances d state laws regulating building construction.
Applicant Signature /1/ L Print Name Bill Gurski Phone : 566-3208
Distribution: White — Office Yellow —Applicant Pink — WWW/Stormwater
THIS APPLICATION EXPIRES 90 DAYS FROM APPLICATION DATE
updated 11-16-201C
F City,
Collins of Planning, Development & Transportation Services
Community Development & Neighborhood Services
2010 FORT COLLINSRESIDENTIAL ENERGY CODE CONPLIANCEFORM
r
Permit Number:
Address: 3409 Buntwing Mane
DIRECTIONS: Place a check next to Prescriptive, UA, or SPA Indicating the path chosen. Next;, circle the
method within that path you intend to follow. If choosing prescriptive or UA, the applicant must also
choose between an Air sealing checklist or Blower Door Test.
(A)PRESCRIPTIVE compliance for house, 2009 IRC, section N1102.1, climate zone S.
BUILDING ENVELOPE
INSULATION R-VALUE
Wood frame wall insul r-value
R-20 or 13+5ci
Metal frame wall insul r-value
R-13+9ci or R-19+8
Crawl space wall
R-13 or R-10cl
Roof insulation in attic
R-38
Roof rafter insulation
R-30
Walls below grade
R-13 / R-10ci
Wood floor over un-cond
R-30
Slab on grade floor, unheat
R-101 24" DEEP
Windows
U-35
Circle one: Air Sealing Checklist
Blower Door Test
I I(S)TOTAL UA ALTERNATIVE (ResCheck), 2009 IRC, SECTION N1102.1.3
a passing UA calculation (i.e. ResCheck) using 2009 IRC/IECC. The rating must be submitted at dme of
;ion and must include address of residence; name of individual completing the rating form; name &
of software tool (i.e. ResCheck). Air Sealing Checklist or Blower Door Test is reauired.
Circle one: Air Sealing Checklist Blower Door Test
(C)SIMULATED PERFORMANCE ALTERNATIVE, 2009 IECC, SECTION 40S
HERS accredited energy rating system. Must submit HERS index of 100 maximum. A preliminary rating
must be submitted at time of application and must include Address of residence; Name of individual completing
the ratan /compllance form; Name & version of software tool. Final rating requires a blower door test.
SIGN: DATE:
CONTRACTOR: KEM Homes Construction, Inc. PHONE? 663-9430
1, i-maj M
cit of Planning, Development & Transportation Services
Fort Collins Community Development & Neighborhood Services
„�. 281 North College Avenue
Fort Collins, CO 80524
970.416.2740
Building Permit Application Submittal: Requirements for
New Single Family Residential Construction (& Additions)
!Revs, 12=3"iknr"
The Items listed below shall be induded in all new requests for building permit. Please initial in front of the
item indicating that it is Induded in the submittal. Only complete submittals will be reviewed.
Current adopted code Is 2009 IRC.
Initiatesock
d Itemg
Permit Application — Threepart form to be completed by applicant.
Fee - (See www.fcgov.com or obtain Fee Schedule at B & Z counter)
%t�dcl"1teeofseliitrytliingltetetllbslow" For Building review.
/tl
Additional 3` set If building Is over 50 years old or older For Historical review
Ito Plans - Architectural site plan, drawn to scale on 8 Ya"x11"sheet showing the location of the
building relative to property lines and other structures on the lot.
rchitectural Drawings - Architectural drawings showing.all floor plans, elevations, stair section,
building section, and wall section detailing all construction components used. Drawings must be drawn
to scale such as 1/4"=1'-0".
Structural Drawings (floor framing & roof framing) —Structural documents bearing an original
al and signature of an architect or engineer registered in the State of Colorado. Structural drawings,
shall include all beams, floor system, roof system, spans, posts, columns, hangers and connections,
and locate and Identify all point loads. Plans shag verify that the design meets the following criteria:
Wind load=100 MPH exposure B, 30-LB roof/snow live load and 15-LB dead load.
Wall Brace Design —Plan showing °&ace wain locations and method of construction. if the house
does not meet the prescriptive brace requirements of 20091RC section R602.10, engineered design
bearing a seal and signature of an architect or engineer registered In the State of Colorado is required.
E gineered Foundation — Foundation documents bearing an original seal and signature of an
►chilect or engineer registered in the State of Colorado. The design requirements shall be for a 30"
frost dept, seismic zone (1) and 30-LB snow load. Identify wet or damp-proof requirements. Identify
and size subsurface drainage system.
nergy Code - (Two Copies) Submit the Fort Collins Energy Code Compliance Form. If SPA method
is selected, preliminary rating must be submitted also. Additions must comply with prescriptiveenergy
code, see the Fort Collins Energy Compliance Form.
AC sizing & load calculations - (Two Copies) Code section M1401.3 requires the HVAC
system be designed based on loads calculated from ACCA manual J, 80i or current edition. Duct sizing
must be included designed per ACCA manual D. See local amendment N1101.1 for Thermal Design
Parameters. Not required for additions.
Other - Include construction, utility, value of construction, description of work and subcontractor
information. Applications must be signed by the applicant and must include a daytime phone number.
Grading Planmay be required if new impervious area is over 350 sq fL Contact Stop-nwater
Development Review at 970-221-6700 for more information.
Applicant Name KEM Homes Construction, ingelephone Number 970-663-9430
Job Site Address 3409 Buntwing Lane
�nS.4
7i c '� s