HomeMy WebLinkAbout5627 Condor Dr - Disclosures/Final Energy - 07/25/2014Fort Collins Energy Cost Compliance
- Non Electric Heat
Property Organization Services
Kern Homes GS Servies
5627 Condor Dr 970-449-1612
Fort Collins, CO 80525 Paul Higman
Weather:Ft. Collins, CO Builder
5627 Condor Dr Kem Homes
Kem Homes 5627 Condor
Annual Energy Cost $/yr
FC 2012
As Designed
Heating
428
446
Cooling
109
73
Water Heating
117
117
SubTotal - Used to Determine Compliance
654
637
Lights Et Appliances
975
971
Photovoltaics
-0
-0
Service Charge
240
240
Total
1870
1848
Mandatory Requirements
Window U-Factor Check (Section 402.5)
Window U-Factor (Design must be equal or lower) 0.400 0.340
Home Infiltration (Section 402.4.2) PASSES
Duct Leakage (Section 403.2.2) PASSES
This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code,
amended by the City of Fort Collins. In fact, this home surpasses the requirements by 2.7%.
Name Paul Higman
Organization GS Servies
Mechanical Systems
Heating
Cooling
Water Heating
Window -to -Floor Area Ratio:
Blower door test
Signature
Date 25 July 2014
Fuel -fired air distribution, 64.0 kBtuh, 95.0 AFUE
Air conditioner, 24.0 kBtuh, 13.0 SEER.
Conventional, Gas, 0.61 EF.
0.10
Htg: 1542 Clg: 1542 CFM50
Digitally signed
by: Paul Higman
DN: CN = Paul
H ig manHigman C = US
Date: 2014.07.25
08:41.55-06'00'
In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to
calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the
design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained
periodically to ensure the compliance calculations reflect current federal minimum standards.
REM/Design - Residential Energy Analysis Software v14.4.
This information does not constitute any warranty of energy cost or savings.
0 1985-2014 Architectural Energy Corporation, Boulder, Colorado.
City of
Fort Collins Planning, Development & Transportation Services
Community Development & Neighborhood Services
Simulated Performance Alternative (SPA) Cover Sheet
Submittal and Rating Type
❑Stock Plan Permit— Projected Worst -Case Rating
R. Lot -specific Permit- Projected Rating
0✓ Completed Home — Confirmed Rating
Data Required for All SPA Ratings
Builder: Kern Homes
Energy rater:
Paul Higman
Builder Model:
Address:
Address: 5627 Condor Dr
Rating Firm: GS Services
Date: 7-17-14
Duct Location Inputs
Location
Su ply
Retum
% Area
R-Value
% Area
R-Value
All within conditioned space
100
0
100
0
Utility Rates
Energy Source
Service charge
I Rate
Electricity
5 $/month
0.10 $/kWh
Natural gas
15 $/month
10.60 $/therm
Spaces considered outside the thermal boundary:
Additional Information for Stock Plan Permit - Projected Worst -Case Rating
"Worst -case" configuration:
Foundation
Options included
Orientation of front elevation
HAftach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report
Attach REM/Rate Energy Code Inspection Checklist
Additional Information for Lot -Specific Permit - Projected Rating
BIach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report
ttach REM/Rate Energy Code Inspection Checklist
Additional Information for Completed Home - Confirmed Rating
❑✓ Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report
(Utility rates reflected in this report must be City -approved rates on lot -specific permit application date.)
❑Attach Home Energy Rating Certificate
Updated 11/09/2012