HomeMy WebLinkAbout2257 Milton Ln - Disclosures/Final Energy - 06/30/2014Fort Collins Energy Cost Compliance
Non Electric Heat
GS er-v ces
Property Organization
_S_
Journey Homes GS Services
2257 Milton Lane 970-449-1612
Fort Collins, CO 80524 Paul Higman
Weather:Ft. Collins, CO Builder
2257 Milton Lane Journey Homes
Journey Homes 2257 Milton
Annual Energy Cost
$/yr
FC 2012
As Designed
Heating
463
456
Cooling
93
72
Water Heating
378
378
SubTotal - Used to Determine Compliance
934
905
Lights & Appliances
777
775
Photovoltaics
-0
-0
Service Charge
240
240
Total
1951
1920
Mandatory Requirements
Window U-Factor Check (Section 402.5)
Window U-Factor (Design must be equal or lower) 0.400 0.350
Home Infiltration (Section 402.4.2) PASSES
Duct Leakage (Section 403.2.2) PASSES
This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code,
amended by the City of Fort Collins. In fact, this home surpasses the requirements by 3.0%.
Name 1 Paul Higman Signature
Organization GS Services Date 30 June 2014
Mechanical Systems
Heating
Cooling
Water Heating
Window -to -Floor Area Ratio:
Blower door test
Fuel -fired air distribution, 73.7 kBtuh, 92.1 AFUE
Air conditioner, 24.0 kBtuh, 13.0 SEER.
Conventional, Elec, 0.95 EF.
0.10
Htg: 1391 Clg: 1391 CFM50
Digitally signed
Paul by: Paul Higman
DN: CN = Paul
Higman Higman C= us
Date: 2014.06.30
08:28:01-06'00'
In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to
calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the
design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained
periodically to ensure the compliance calculations reflect current federal minimum standards.
REM/Design - Residential Energy Analysis Software v14.4.1
This information does not constitute any warranty of energy cost or savings.
0 1985-2014 Architectural Energy Corporation, Boulder, Colorado.
rt Collins
Planning, Development & Transportation Services
Community Development & Neighborhood Services
Simulated Performance Alternative (SPA) Cover Sheet
Submittal and Rating Type
Flock Plan Permit — Projected Worst -Case Rating
Lot -specific Permit - Projected Rating
❑� Completed Home — Confirmed Rating
Data Required for All SPA Ratings
Builder: Journey Homes
Energyrater: Paul Higman
Builder Model:
Address:
Address: 2257 Milton Lane
Rating Firm:
GS Services
Date: 6-28-14
Duct Location Inputs
Location
Su ply
Return
%Area
R-Value
% Area
R-Value
All within conditioned space
100
0
100
0
Utility Rates
Energy Source
Service charge
Rate
Electricity
5 $/month
0.10 $/kWh
Natural gas
15 $/month
0.60 $/therm
Spaces considered outside the thermal boundary:
Additional Information for Stock Plan Permit — Projected Worst -Case Rating
"Worst -case" configuration:
Foundation type(s)
Options included
Orientation of front elevation
eAttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report
Attach REM/Rate Energy Code Inspection Checklist
Additional Information for Lot -Specific Permit— Projected Rating
ttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report
ttach REM/Rate Energy Code Inspection Checklist
Additional Information for Completed Home — Confirmed Rating
ZAttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report
(Utility rates reflected in this report must be City -approved rates on lot -specific permit application date.)
Attach Home Energy Rating Certificate