Loading...
HomeMy WebLinkAbout7217 Laramie River Rd - Disclosures/Final Energy - 05/03/2014City of Fort Collins Planning, Development & Transportation Services Community Development & Neighborhood Services Simulated Performance Alternative (SPA) Cover Sheet Submittal and Rating Type ❑Stock Plan Permit — Projected Worst -Case Rating ❑Lot -specific Permit - Projected Rating ✓❑ Completed Home — Confirmed Rating Data Required for All SPA Ratings Builder: Luxury Homes of Norther Colorado Energy rater: Paul Higman Builder Model: Address: Address: 7217 Larimie River Rating Firm: GS Services Date: 5-3-14 Duct Location Inputs Location Su ply Return % Area R-Value % Area R-Value All within conditioned space 100 0 100 0 Utility Rates Energy Source Service charge Rate Electricity 5 $/month 0.10 $/kWh Natural gas 15 $/month 10.60 $/therm Spaces considered outside the thermal boundary: Additional Information for Stock Plan Permit — Projected Worst -Case Rating 'Worst -case" configuration: Foundation type(s) Options included Orientation of front elevation HAftach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report Attach REM/Rate Energy Code Inspection Checklist Additional Information for Lot -Specific Permit — Projected Rating Bttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report ttach REM/Rate Energy Code Inspection Checklist Additional Information for Completed Home — Confirmed Rating Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report (Utility rates reflected in this report must be City -approved rates on lot -specific permit application date.) [—]Attach Home Energy Rating Certificate Updated 11/09/2012 Fort Collins Energy Cost Compliance . Non Electric Heat Property Organization GS S .i-c:es Luxury Homes of NC GS Services 7217 Larimie River 970-223-7090 Fort Collins, CO 80526 Paul Higman Weather:Ft. Collins, CO Builder 7217 Larimie River Luxury Homes of NC Luxury Homes of NC -7217 Annual Energy Cost $/yr FC 2012 As Designed Heating 497 411 Cooling 136 ill Water Heating 174 164 s- Uaed°to Determine Gomplian'ce 806 687 Lights B: Appliances 1266 1250 Photovoltaics .0 -0 Service Charge 240 240 Total 2312 2177 Mandatory Requirements Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower) 0.400 0.340 Home Infiltration (Section 402.4.2) PASSES Duct Leakage (Section 403.2.2) PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 14.9%. Name '. Paul Higman Organization I GS Services Mechanical Systems Heating Cooling Water Heating Window -to -Floor Area Ratio: Blower door test Signature' Date 5 May 2014 Fuel -fired air distribution, 96.0 kBtuh, 95.0 AFUE. Air conditioner, 36.0 kBtuh, 13.0 SEER. Conventional, Gas, 0.58 EF. 0.07 Htg: 1667 Clg: 1667 CFM50 Digitally signed Paul by: Paul Higman DN: CN = Paul HigmanHigmanC = US Dade: 2014.05.05 0$:43:22-06'00' In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Design - Residential Energy Analysis Software 04.4.1 This information does not constitute any warranty of energy cost or savings. 0 1985-2014 Architectural Energy Corporation, Boulder, Colorado.