Loading...
HomeMy WebLinkAbout7217 Laramie River Rd - Disclosures/Blower Door Test - 05/03/2014BUILDING LEAKAGE TEST X GS Services 2000 S. College Ave suite #308 Fort Collins, CO 80525 Date of Test: 5/3/2014 Test File: Luxury Homes of NC -7217 Larimie River -BD Customer: Luxury Homes of NC Technician: Paul Higman Project Number: Fort Collins, CO 80527 Building Address: 7217 Larimie River Fort Collins, CO 80526 Test Results 1. Airflow at 50 Pascals: 1667 CFM50 (+/- 0.6 %) (50 Pa = 0.2 w.c.) 2.01 ACH50 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: 5. Accuracy Level 91.7 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 294.6 ( +/- 4.3 %) Exponent (n) = 0.443 ( +/- 0.012 ) Correlation Coefficient = 0.99954 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 83.4 CFM 0.10 ACH 2. Estimated Design Infiltration Rate: Winter: 151.8 CFM Summer: 100.8 CFM 0.18 ACH 0.12 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Pa U I Digitally signed by�O.aul Higman DN:,CN = Paul H igmanHigman C = US Da(e. 2014.05.05 08:40:15-06'00' C75 CeS BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 5/3/2014 Test File: Luxury Homes of NC -7217 Larimie River -BD Building Information Volume 49700 Surface Area Floor Area 4808 Height 12 # of Bedrooms 5 # of Occupants Year of Construction 2014 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 65�@IVIES BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 5/3/2014 Test File: Luxury Homes of NC -7217 Larimie River -BD Depressurization Test: Environmental Data Indoor Temperature (A*F) Outdoor Temperature (A°F) Altitude (ft) 67.0 72.0 4980.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -2.1 n/a n/a -60.4 -58.4 99.6 -55.4 -53.4 91.7 -50.2 -48.2 84.3 -45.1 -43.1 76.4 -40.4 -38.4 69.3 -35.5 -33.5 60.2 -30.7 -28.6 51.8 -25.2 -23.1 44.1 -20.2 -18.1 34.3 -2.0 n/a n/a Time Averaging Period: 10 1792 1780 -0.3 Ring A 1721 1710 -0.3 Ring A 1652 1641 0.1 Ring A 1575 1565 0.3 Ring A 1501 1491 0.6 Ring A 1402 1393 -0.2 Ring A 1303 1294 -0.6 Ring A 1204 1196 0.9 Ring A 1065 1058 -0.6 Ring A Deviations from Standard RESNET Multi -Point Test - Test Parameters None * n value outside of normally accepted limits. * n value and/or correlation coefficient limits are not officially part of the RESNET Multi -Point Test Standard. GAS BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 5/3/2014 Test File: Luxury Homes of NC -7217 Larimie River -BD Comments House WRT Garage =-48.9pa