Loading...
HomeMy WebLinkAbout4856 Innovation Dr - Special Inspections/Field Verification - 04/21/2014 (2)Lawrence H. Finn & Associates, Inc. 55 S. Elm Ave., Suite 220 — Eaton, CO 80615 Phone (970) 454-5351 — Fax (970) 454-5391 2389 CERTIFIED TEST, ADJUST, AND BALANCE REPORT DATE 4/21/14 PROJECT F + W Media Innovation Campus Bldg 1 & 2 4856 / 4868 Innovation Drive Fort Collins, CO ARCHITECT Waring Associates 1875 Lawrence, Suite 700 Denver, CO ENGINEER MDP Engineering Group, P.C. 1800 Glenarm Place, Suite 800 Denver, CO CONTRACTOR Academy Heating & Cooling 1205 2nd Street Eaton, CO � I � Lawrence He Finn & Associates, Inc. Roof Top Unit PROJECT: F+W Media (Bldg #1) LOCATION: Fort Collins, CO SYSTEM/UNIT: (N)RTU-03 AREA: Unit Manufacturer Unit Model Number Unit Serial Number Unit Discharge Fan Type Fan Size Fan Class Fan Arrangement Fan Discharge Filter Manufacturer Filter Type Filter Quantity Filter Size Trane YSC048E4EHA1SD001000 140912389L Vertical/Down Forward Curve 10"ID 1 DWDI Vertical/Down Purolator Disposable 2 20x3Ox2 7(N)RTU-03 / Suooly Fan nstalled Thermal Internal Total CFM Design 1600 CFM Total CFM Actual 1615 CFM Outside Air CFM Design 320 CFM Outside Air CFM Actual 336 CFM Return Air CFM Design 1280 CFM Return Air CFM Actual 1279 CFM DATE: 4/21 /2014 CONTACT: Dave Reichel NE_ BB 2389 Tested By: Wade Wilson Test Date: April 16, 2014 Motor Manufacturer Marathon Motor Frame 56 Motor HP 1 HP Motor RPM 1725 RPM Motor Rated Volts 200-2301460 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 4.0-5.0/2.5 Amps Motor Service Factor 1.5 Motor Sheave Make Browning Motor Sheave Model 1VL34 Motor Sheave Diam. 3-1/4 in. Motor Sheave Bore 5/8 in. Motor Operating Diameter 2-1/2 in. Fan Sheave Make Browning Fan Sheave Model AK49 Fan Sheave Diam. 4-3/4 in. Fan Sheave Bore 3/4 in. Number of Belts 1 Belt Size AX26 Sheave Center Line 8-1/2 in. U-03 / Supply Fan Fan SP In Actual -0.31 in. we Fan RPM Actual 1006 RPM Fan SP Out Actual 0,19 in. we Motor Volts 1 489 Volts OA Damper Pos Actual 19 % Motor Volts 2 490 Volts RA Damper Pos Actual 81 % Motor Votts 3 488 Volts Unit External SP Design 1.0 in. we Motor Amps 1 1.6 Amps Unit External SP Actual 0.26 in. we Motor Amps 2 1.5 Amps Filter/Coil SP In -0.07 in. we Motor Amps 3 1.6 Amps Filter/Coil SP Out -0.31 in, we (N)RTU-03 Supply Outlet Summary System / Unit Area Served Outlet Type Size LxW / D AK Faalmr Maximum Prelim Reading Maximum % Prelim Final Deviation % Final DeeikMon Outlet-01 110 N 24x24 320 ;;9C, 317 124 99 Outlet-02 110 N 24x24 320 400 330 125 103 Outlet-03 110 N 24x24 320 461 322 144 101 Outlet-04 110 N 24x24 320 405 329 127 103 Outlet-05 110"may{ N 24x24 320 372 317 116 99 ll ti * Notes L. H Finn and Associates Final Report Page 12 of 41 Lawrence H. Finn & Associates, Inc. Roof Top Unit PROJECT: F+W Media (Bldg #1) LOCATION: Fort Collins, CO SYSTEM/UNIT: (N)RTU-04 AREA: DATE: 4/21 /2014 CONTACT: Dave Reichel NE, BB 2389 Tested By: Wade Wilson Test Date: April 16, 2014 Unit Manufacturer Trane (N1RTU-04 / Supply Fan Unit Model Number YSC060E4EHA1 ND001000 Motor Manufacturer Marathon Unit Serial Number 140912475L Motor Frame 56 Unit Discharge Vertical/Down Motor HP 1 HP (N)RTU-04 / Supply Fan Motor RPM 1725 RPM Fan Type Forward Curve Motor Rated Volts 200-230/460 Volts Fan Size 10"ID Motor Phase 3 Fan Class 1 Motor Hertz 60 Hz Fan Arrangement DWDI Motor FL Amps 4.0-5.0/2.5Amps Fan Discharge Vertical/Down Motor Service Factor 1.5 (N)RTU-04 / Filter Bank Filter Manufacturer Purolator Filter Type Disposable Filter Quantity 2 (N)RTU-04 / Supply Fan Filter Size 20x3Ox2 Motor Sheave Make Browning Motor Sheave Diam. 3-1/4 in. Motor Sheave Bore 5/8 in. Motor Operating Diameter 2 1/2 in. (N)RTU-04 / Supply Fan Fan Sheave Make Browning Installed Thermal Internal Fan Sheave Model AK44 Fan Sheave Diam. 4-1/4 in. Fan Sheave Bore 3/4 in. Number of Belts 1 Total CFM Design 2000 CFM Belt Size AX26 Total CFM Actual 1999 CFM Sheave Center Line 8-1/2 in. Outside Air CFM Design 400 CFM Test P�@SSUFBS Outside Air CFM Actual 389 CFM Return Air CFM Design 1600 CFM Return Air CFM Actual 1610 CFM Fan SP In Actual -0.40 in. we (N1RTU-04 / Supply Fan Fan SP Out Actual 0.20 in. we Fan RPM Actual 1019 RPM OA Damper Pos Actual 23 % Motor Volts 1 490 Volts RA Damper Pos Actual 77 % Motor Volts 2 491 Volts Unit External SP Design 1.0 in. we Motor Volts 3 491 Volts Unit External SP Actual 0.40 in. we Motor Amps 1 1.5 Amps Filter/Coil SP In -0.20 in. we Motor Amps 2 1.4 Amps Filter/Coil SP Out -0.40 in. we Motor Amps 3 1 A Amps (N)RTU-04 / Supply Fan Fan TSP Actual 0.60 in. we (N)RTU-04 Supply Outlet Summary Type Size LxW / D AK Factor Maximum Design Prelim Reading Maximum Final % Prelim Deviation % Final Deviation Outlet-01 133 SWR 18x12 400 418 404 105 101 Outlet-02 133 SWR 18x12 400 618 396 155 99 Outlet-03 133 SWR 18xl2 400 496 397 124 99 Outlet-04 133 SWR 18x12 400 453 399 113 100 Outlet-05 133 SWR 1802 400 456 403 114 101 * Notes L. H. Finn and Associates Fina/Report Page 13 of 41 Lawrence H. Finn & Associates, Inc. Ni. B 2389 Fan Unit PROJECT: F+W Media (Bldg #1) DATE: 4/21/2014 LOCATION: Fort Collins, CO CONTACT: Dave Reichel SYSTEM/UNIT: TF-01 AREA: Fan Manufacturer Twin City Fan Fan Model Number T400 Fan Type Forward Curve Fan Size 6" ID Fan Class 1 Fan Arrangement DWDI Fan Discharge Horizontal Installed Thermal Internal Total CFM Design 300 CFM Total CFM Actual 325 CFM Fan RPM Actual Direct Drive RPM Motor Volts 1 120 Volts Motor Amps 1 1.0 Amps SP In Actual -0.07 in. we SP Out Actual 0.09 in. we Total SP Design 0.25 in. we Total SP Actual 0.16 in. we TF-01 Exhaust Inlet Summary " Notes Tested By: Josh Behrendsen Test Date: April 16, 2014 Motor Manufacturer Broan Motor RPM Direct Drive RPM Motor Rated Volts 115 Volts Motor Phase 1 Motor Hertz 60 Hz Motor FL Amps 1.3 Amps Motor Sheave Make WrectWnve� L.N. Finn and Associates Final Report Page 29 of 41 • g / �{o0 9l8 .. r Lawrence H. Finn & Associates, Inc. 11441 55 S. Elm Ave, Suite 220 — Eaton, CO 80615 2389 Phone (970) 454-5351 — Fax (970) 454-5391 PROJECT: F + W Media Innovation Campus Bldg 1 & 2 ADDRESS: 4856 / 4868 Innovation Drive Fort Collins, CO The data presented in this report is an exact record of the system performance and was obtained in accordance with NEBB Standard Procedures. Any variances from design quantities which exceed NEBB tolerances are noted throughout the report. The air distribution systems have been tested & balanced and final adjustments have been made in accordance with NEBB "Procedural Standards for Testing, Adjusting, Balancing of Environmental Systems" and the project specifications. NEBB TAB FIRM: Lawrence H. Finn & Associates, Inc. REG. NO.: 2389 CERTIFIED BY: David C. Reichel DATER/21/14 The hydronic distribution systems have been tested & balanced and final adjustments have been made in accordance with NEBB "Procedural Standards for Testing, Adjusting, Balancing of Environmental Systems" and the project specifications. NEBB TAB FIRM: Lawrence H. Finn & Associates, Inc. REG. NO.: 2389 CERTIFIED BY: David C. Reichel DATER/21/14 SUBMITTED & CERTIFIED BY NEBB TAB FIRM: Lawrence H. Finn & Associates, Inc. TAB SUPERVISOR: David C. Reichel REG. NO.: 2389 SIGNATURE: DATE: 4/21/14 CERTIFICATION EXPIRATION DATE: 3/31/2016 Lawrence He Finn & Associates, Inc. Roof Top Unit PROJECT: F+W Media (Bldg #1) LOCATION: Fort Collins, CO SYSTEM/UNIT: (E)RTU-04 AREA: Unit Manufacturer Carrier Unit Model Number 48TFE009-M601AA Unit Serial Number 0101G30445 Unit Discharge Vertical/Down U-04 / Supply Fan Fan Type Forward Curve Fan Size 12"ID Fan Class 1 Fan Arrangement DWDI Fan Discharge Vertical/Down U-04 / Filter Bank Filter Manufacturer Koch Filter Type Pleated Filter Quantity 4 Filter Size 16x20x2 (E)RTU-04 / Supply Fan Installed Thermal Internal 77 Total CFM Design 3425 CFM Total CFM Actual 3601 CFM Outside Air CFM Design None Shown CFM DATE: 4/21 /2014 CONTACT: Dave Reichel Motor Manufacturer Motor Frame Motor RPM Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps Motor Service Factor 2389 Tested By: Joe Castanon Test Date: April 15, 2014 GE 56HZ 1725 RPM 208-230/460 Volts 3 60 Hz 10.2/4.8 Amps 1.15 Motor Sheave Make Browning Motor Sheave Model Adjustible Motor Sheave Diam. 5-1/2 in. Motor Sheave Bore 7/8 in. Motor Operating Diameter 4-3/4 in. Fan Sheave Make Maurey Fan Sheave Model Fixed Fan Sheave Diam. 8-1/2 in. Fan Sheave Bore 1 in. Number of Belts 1 Belt Size A-53 Sheave Center Line 17-1/2 in. Fan RPM Actual 919 RPM Motor Volts 1 491 Volts Fan SP In Actual -0.70 in. we Motor Volts 2 491 Volts Fan SP Out Actual 0.60 in. we Motor Volts 3 491 Volts Unit External SP Actual 0.85 in. we Motor Amps 1 4.0 Amps Filter/Coil SP In -0.25 in. we Motor Amps 2 4.1 Amps Filter/Coil SP Out -0.70 in. we Motor Amps 3 4.0 Amps (E)RTU-04 / Supply Fan Fan TSP Actual 1.3 in, we L.H. Finn and Associates Final Report Page 4 of 41 Lawrence H. Finn & Associates, Inc. Roof Top Unit PROJECT: F+W Media (Bldg #1) LOCATION: Fort Collins, CO SYSTEM/UNIT: (E)RTU-04 (Cont.) AREA: (E)RTU-04 Supply Outlet Summary DATE: 4/21 /2014 CONTACT: Dave Reichel NNIP 2389 Tested By: Joe Castanon Test Date: April 15, 2014 Ptlet-Ot 109 N 24x24 225 220 239 98 106 Outlet-02 109 N 24x24 225 203 238 90 106 Outlet-03 108 CD 24x24 225 353 235 157 104 Outlet-04 See Print N 24x24 225 196 237 87 105 Outlet-05 107 CD 24x24 225 399 237 177 105 Outlet-06 106 CD 24x24 225 373 241 166 107 Outlet-07 See Print N 24x24 225 188 235 84 104 Outlet-08 105 N 24x24 250 349 254 140 102 Outlet-09 105 N 24x24 250 175 251 70 100 Outlet-10 103 CD 24x24 225 327 241 145 107 Outlet-11 102 CD 24x24 225 207 242 92 108 Outlet-12 See Print N 24x24 225 124 235 55 104 Outlet-13 101 CD 24x24 225 276 237 123 105 Outlet-14 100 R 24x24 225 283 239 126 106 Outlet-15 100 R 24x24 225 283 240 126 107 Notes L. H Finn and Associates Final Report Page 5 of 41 Lawrence H. Finn & Associates, Inc. Roof Top Unit PROJECT: F+W Media (Bldg #1) LOCATION: Fort Collins, CO SYSTEM/UNIT: (E)RTU-05 AREA: Unit Manufacturer Carrier Unit Model Number 48TFDO06-6010A Unit Serial Number 510OG24521 Unit Discharge Vertical/Down U-05 / Supply Fan Fan Type Forward Curve Fan Size 8"ID Fan Class 1 Fan Arrangement DWDI Fan Discharge Vertical/Down U-05 I Filter Bank Filter Manufacturer Koch Filter Type Pleated Filter Quantity 2 Filter Size 16x25x2 (E)RTU-05 / Supply Fan Installed Thermal Internal Total CFM Design 2000 CFM Total CFM Actual 1977 CFM Outside Air CFM Design Not Shown CFM DATE: 4/21 /2014 CONTACT: Dave Reichel Motor Manufacturer Motor Frame Motor RPM Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps Motor Service Factor NJ101 2389 Tested By: Joe Castanon Test Date: April 15, 2014 GE 56Y 1725 RPM 208-230/460 Volts 3 60 Hz 5.2/2.6 Amps 1.15 Motor Sheave Make Browning Motor Sheave Model Adjustable Motor Sheave Diam. 4 in. Motor Sheave Bore 5/8 in. Motor Operating Diameter 3-3/4 in. Fan Sheave Make Maurey Fan Sheave Model AC58 Fan Sheave Diam. 5-3/4 in. Fan Sheave Bore 5/8 in. Number of Belts 1 Belt Size A40 Sheave Center Line 13-1/4 in. Fan RPM Actual 1177 RPM Motor Volts 1 490 Volts Fan SP In Actual -0.50 in. we Motor Volts 2 491 Volts Fan SP Out Actual 0.40 in. we Motor Volts 3 490 Volts Unit External SP Actual 0.55 in. we Motor Amps 1 1.6 Amps Filter/Coil SP In -0.15 in. we Motor Amps 2 1.7 Amps Filter/Coil SP Out -0.50 in. we Motor Amps 3 1.6 Amps (E)RTU-05 / Supply Fan Fan TSP Actual 0.90 in. we L.H.. Finn and Associates Fina/Report Page 6 of 41 r Lawrence H. Finn & Associates, Inc. NE: BB 2389 Roof Top Unit PROJECT: F+W Media (Bldg #1) LOCATION: Fort Collins, CO SYSTEM/UNIT: (E)RTU-05 (Cont) AREA: (E)RTU-05 Supply Outlet Summary DATE: 4/21 /2014 CONTACT: Dave Reichel Tested By: Joe Castanon Test Date: April 15, 2014 Outlet-01 See Print N 24x24 225 229 227 102 101 Outlet-02 121 N 24x24 150 151 153 101 102 Outlet-03 122 N 24x24 50 81 52 162 104 Outlet-04 116 CD 24x24 225 226 224 100 100 Outlet-05 115 CD 24x24 225 220 222 98 99 Outlet-06 114 CD 24x24 225 200 223 89 99 Outlet-07 113 CD 24x24 225 199 219 88 97 Outlet-08 112 CD 24x24 225 254 224 113 100 Outlet-09 111 R 24x24 225 f 199 216 88 96 Outlet-10 111 R 24x24 225 230 217 102 96 * Notes L.H. Finn and Associates Final Report Page 7 of 41 Lawrence He Finn & Associates, Inc. Roof Top Unit PROJECT: F+W Media (Bldg #1) LOCATION: Fort Collins, CO SYSTEM/UNIT: (E)RTU-06 AREA: Unit Manufacturer Carder Unit Model Number 48TFDO12-601QA Unit Serial Number 510OG34025 Unit Discharge Vertical/Down J-06 / Supply Fan Fan Type Forward Curve Fan Size 12"ID Fan Class 1 Fan Arrangement DWDI Fan Discharge Vertical/Down Filter Manufacturer Koch Filter Manufacturer Koch Filter Type Pleated Filter Type Pleated Filter Quantity 4 Filter Quantity 4 Filter Size 20x2Ox2 Filter Size 20x2Ox2 (E)RTU-06 / Supply Fan Installed Thermal Internal DATE: 4/21 /2014 CONTACT: Dave Reichel Motor Manufacturer Motor Frame Motor RPM Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps Motor Service Factor r NE BB 2389 Tested By: Joe Castanon Test Date: April 16, 2014 GE 56Y 1725 RPM 208-230/460 Volts 3 60 Hz 7.5/3.4 Amps 1.15 Motor Sheave Make Browning Motor Sheave Model Adjustable Motor Sheave Diam. 4 3/4 in. Motor Sheave Bore 7/8 in. Motor Operating Diameter 4 1/4 in. Fan Sheave Make Browning Fan Sheave Model Fixed Fan Sheave Diam. 7 in. Fan Sheave Bore 1 in. Number of Belts 1 Belt Size A51 Sheave Center Line 17 1/2 in. Total CFM Design 4000 CFM Total CFM Actual 4261 CFM Fan SP In Actual -1.20 in. we Outside Air CFM Design None Shown CFM Fan SP Out Actual 0.90 in. we U-06 / Supply Fan Unit External SP Actual 1.55 in. we Fan RPM Actual 988 RPM Fiter/Coil SP In -0.65 in. we Motor Volts 1 491 Volts Filter/Coil SP Out -1.20 in. we Motor Volts 2 490 Volts IEEIRTU-06 / Supply Fan Motor Volts 3 491 Volts Fan TSP Actual 2.10 in. we Motor Amps 1 5.4 Amps Motor Amps 2 5.2 Amps Motor Amps 3 5.2 Amps L. H. Finn and Associates Final Report Page 8 of 41 Lawrence H. Finn & Associates, Inc. Roof Top Unit PROJECT: F+W Media (Bldg #1) LOCATION: Fort Collins, CO SYSTEM/UNIT: (E)RTU-06 (Cont.) AREA: (E)RTU-06 Supply Outlet Summary DATE: 4/21 /2014 CONTACT: Dave Reichel NEE BB 2389 Tested By: Joe Castanon Test Date: April 16, 2014 Outlet-01 125 CD 24x24 200 471 213 236 107 Outlet-02 123 N 24x24 150 137 161 91 107 Outlet-03 123 N 24x24 150 132 159 88 106 Outlet-04 123 N 24x24 150 114 160 76 107 Outlet-05 123 N 24x24 150 152 158 101 105 Outlet-06 123 N 24x24 150 206 162 137 108 Outlet-07 123 N 24x24 150 114 158 76 105 Outlet-08 123 N 24x24 150 179 160 119 107 Outlet-09 123 N 24x24 150 144 161 96 107 Outlet-10 123 N 24x24 150 243 158 162 105 Outlet-11 123 N 24x24 150 135 160 90 107 Outlet-12 123 N 24x24 150 159 158 106 105 Outlet-13 123 N 24x24 150 117 158 78 105 Outlet-14 123 N 24x24 150 177 159 118 106 Outlet-15 123 N 24x24 150 153 160 102 107 Outlet-16 123 N 24x24 150 244 161 163 107 Outlet-17 123 N 24x24 150 112 160 75 107 Outlet-18 126 CD 24x24 100 192 107 192 107 Outlet-19 127 CD 24x24 100 227 105 227 105 Outlet-20 128 CD 24x24 100 220 107 220 107 Outlet-21 129 CD 24x24 100 179 107 179 107 Outlet-22 130 CD 24x24 100 181 108 181 108 Outlet-23 130 N 24x24 150 141 159 94 106 Outlet-24 130 N 24x24 150 194 162 129 108 Outlet-25 130 N 24x24 150 160 161 107 107 Outlet-26 130 N 24x24 150 154 161 103 107 Outlet-27 130 N 24x24 150 260 159 173 106 Outlet-28 130 N 24x24 150 52 159 35 106 * Notes L. H. Finn and Associates Fina/Report Page 9 of 41 Lawrence He Finn & Associates, Inc. NE BB 2389 Roof Top Unit PROJECT: F+W Media (Bldg #1) LOCATION: Fort Collins, CO SYSTEM/UNIT: (E)RTU-07 AREA: Unit Manufacturer Carrier Unit Model Number 48TFD005-M-601AA Unit Serial Number 0101 G20477 Unit Discharge Vertical/Down J-07 / Supply Fan Fan Type Forward Curve Fan Size 9"ID Fan Class 1 Fan Arrangement DWDI Fan Discharge Vertical/Down J-07 / Filter Bank Fitter Manufacturer Koch Filter Type Pleated Fiker Quantity 2 Fiker Size 16x25x2 (E)RTU-07 / Supply Fan Installed Thermal Internal Total CFM Design 1600 CFM Total CFM Actual 1674 CFM Outside Air CFM Design None Shown CFM DATE: 4/21 /2014 CONTACT: Dave Reichel Tested By: Wade Wilson Test Date: April 16, 2014 Motor Manufacturer GE Motor Frame 56Y Motor RPM 1725 RPM Motor Rated Volts 208-230/460 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 5.2/2.6 Amps Motor Service Factor 1.15 Motor Sheave Make Browning Motor Sheave Model Adjustable Motor Sheave Diam. 4 in. Motor Sheave Bore 5/8 in. Motor Operating Diameter 3 in. Fan Sheave Make Maurey Fan Sheave Diam. 4 3/4 in. Fan Sheave Bore 5/8 in. Number of Belts 1 Belt Size A39 Sheave Center Line 14 in. Fan RPM Actual 1092 RPM Fan SP In Actual -0.5 in. we Motor Volts 1 491 Volts Fan SP Out Actual 0.9 in. we Motor Volts 2 490 Volts External SP In Actual -0.25 in. we Motor Volts 3 490 Volts External SP Out Actual 0.9 in. we Motor Amps 1 1.5 Amps Unit External SP Actual 1.15 in. we Motor Amps 2 1.6 Amps Fitter/Coil SP In -0.25 in. we Motor Amps 3 1.6 Amps Fitter/Coil SP Out -0.5 in. we (E)RTU-07 Supply Outlet Summary Outlet-01 134 N 24x24 300 359 323 120 108 Outlet-02 132 N 24x24 225 378 233 168 104 Outlet-03 132 N 24x24 225 308 231 137 103 Outlet-04 132 N 24x24 225 283 230 126 102 Outlet-05 132 N 24x24 225 322 232 143 103 Outlet-06 135 N 24x24 200 279 213 140 107 Outlet-07 135 N 24x24 200 210 212 105 106 ss 11 rode .i -" ✓ .....:.. r y �, ,_.,._ y ...,,. :.. .. * Notes L. H Finn and Associates Final Report Page 10 of 41 Lawrence He Finn & Associates, Inc. Roof Top Unit PROJECT: F+W Media (Bldg #1) LOCATION: Fort Collins, CO SYSTEM/UNIT: (N)RTU-02 AREA: Unit Manufacturer Trane Unit Model Number YSC036E4EHAOOC8 Unit Serial Number 140912391 L Unit Discharge Vertical/Down U-02 / Supply Fan Fan Type Forward Curve Fan Size 10"ID Fan Class 1 Fan Arrangement DWDI Fan Discharge Vertical/Down U-02 / Filter Bank Filter Manufacturer Purolator Filter Type Disposable Filter Quantity 2 Filter Size 20x3Ox2 I� (N)RTU-021 Supply Fan Installed Thermal Internal Total CFM Design 1200 CFM Total CFM Actual 1290 CFM Outside Air CFM Design 240 CFM Outside Air CFM Actual 242 CFM Return Air CFM Design 960 CFM Return Air CFM Actual 1048 CFM DATE: 4/21 /2014 CONTACT: Dave Reichel Motor Manufacturer Motor Frame Motor HP Motor RPM Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps Motor Service Factor NE BB 2389 Tested By: Wade Wilson Test Date: April 16, 2014 Marathon 56 1 HP 1725 RPM 200-230/460 Volts 3 60 Hz 4.0-5.0/2.5 Amps 1.5 Motor Sheave Make Browning Motor Sheave Model 1 VL34 Motor Sheave Diam. 3 1 /4 in. Motor Sheave Bore 5/8 in. Motor Operating Diameter 2 1/2 in. Fan Sheave Make Browning Fan Sheave Model AK51 Fan Sheave Diam. 5 in. Fan Sheave Bore 3/4 in. Number of Belts 1 Belt Size AX26 Sheave Center Line 8 in. U-02 / Supply Fan Fan SP In Actual -0.14 in. we Fan RPM Actual 1033 RPM Fan SP Out Actual 0.30 in. we Motor Volts 1 491 Volts OA Damper Pos Actual 22 % Motor Volts 2 490 Volts RA Damper Pos Actual 78 % Motor Volts 3 491 Volts Unit External SP Design 1.0 in. we Motor Amps 1 1.6 Amps Unit External SP Actual 0.38 in. we Motor Amps 2 1.6 Amps Filter/Coil SP In -0.08 in. we Motor Amps 3 1.4 Amps Filter/Coll SP Out -0.14 in. we (N)RTU-02 Supply Outlet Summary System I Unit Area Served Outlet Type Size LxW 10 AK Factor Maximum Design Pngm Maximum RMdIpO ilmil % Prelim 9"Wilmt % F Outlet-01 i i 9 N 24x24 250 287 262 115 105 Outlet-02 119 N 24x24 250 425 271 170 108 Outlet-03 119 N 24x24 250 424 265 170 106 Outlet-04 118 R 24x24 225 394 244 175 108 Outlet-05 118 R 24x24 225 310 248 138 110 * Notes L. H. Finn and Associates Final Report Page 11 of 41