Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
738 Campfire Dr - Disclosures/Final Energy - 06/25/2014
BURGESS 5aV/#DR;ZHorton4&VR 1220 004C 738 Campfire Drive III YYY III Fort Collins, CO 80524 CONSTRUCTION CONSULTANTS � INC. SINCE 19T6 5 Stars Plus Confirmed Uniform Energy Rating System Energy Efficient 1 Star 1 Star Plus 2 Stars '2 Stars Plus 3 Stars 3 Stars Plus 4 Stars 4 Stars Plus 5 Stars 5 Stars Plus 500-401 400-301 300-251 250-201 200-151 150-101 100-91 90-86 85-71 70 or Less HERS Index: 69 Conditioned Area: 1854 sq. ft. Conditioned Volume: 15004 cubic ft. Efficient Home Comparison: 31% Better HouseType: Single-family detached Foundation: Conditioned basement Bedrooms: 3 Ifllechanical�Systems Features Heating: Fuel -fired air distribution, Natural gas, 92.0AFUE. Water Heating: Conventional, Natural gas, 0.65 EF, 40.0 Gal. Duct Leakage to Outside: 0.00 CFM25. Ventilation System: Exhaust Only: 50 cfm, 11.3 watts. Programmable Thermostat: Heating: Yes Cooling:Yes Building.5hel1 Features Ceiling Flat: R-38.0 Slab: R-0.0 Edge, R-0.0 Under Sealed Attic: NA Exposed Floor: R-30.0 Vaulted Ceiling: NA Window Type: U-Value: 0.340, SHGC: 0.300 Above Grade Walls: R-15.0 Infiltration Rate: Htg: 900 Clg: 906 CFM50 Foundation Walls: R-19.0 Method: Blower door test Percent Interior Lighting: 50.00 Range/Oven Fuel: Natural gas Percent Garage Lighting: 0.00 Clothes Dryer Fuel: Electric Refrigerator (kWh/yr): 775.00 Clothes Dryer EF: 2.67 Dishwasher Energy Factor: 0.46 Ceiling Fan (cfm/Watt): 0.00 The Home Energy Rating Standard Disclosure for this home is available from the rating provider. REM/Rate - Residential Energy Analysis and Rating Software v14A This information does not constitute any warranty of energy cost or savings. ©1985-2013Arch tectural Energy Corporation, Boulder, Colorado. Registry ID: Rating Number: Certified Energy Rater: Rating Date: Rating Ordered For: 017396231 Worst Case Scenario Robert Hutchinson 06/25/2014 DR Horton Estimated Annual Energy Cost Confirmed Use MMBtu Cost Percent Heating 39.9 $259 21 % Cooling 0 $0 0% Hot Water 18.9 $113 9% Lights/Appliances 24.5 $647 51% Photovoltaics -0.0 $-0 -0% Service Charges $240 19% Total 85.1 $1259 100% SIMINIM This home meets or exceeds the minimum criteria for all of the following: EPA ENERGY STAR Version 2 Home 2006 International Energy Conservation Code 2009 International Energy Conservation Code Burgess Consultants pRTGA 101 W Renner Rd o+'�M Gf�tioG Suite 400 - 2` 11 Richardson, TX 75082 �r 214-888-7300 No. 99-144 wQ 214-888-7266 ^\ 9CCRk0ITATI0" mama � Certified Energy Rater BURGESS i � Ha°eFbeo-t" F CONSTRUC10\ CONSUL7.4N'rS t� pie INC. �wto,iene" S:�Cf ,asn FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Date: June 26, 2014 Rating No.: Worst Case Scenario Building Name: DR Horton 1220 Rating Org.: Burgess, Inc Owners Name: DR Horton Phone No.: 303-300-4527 Property: 738 Campfire Drive Rater's Name: Robert Hutchinson Address: Fort Collins, CO80524 Rater'sNo.: 7479033 Builder's Name: DR Horton Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 738 Campfire Drbg Rating Date: 06/25/2014 Annual Energy Cost ($) FC 2012 As Designed Heating: 319 304 Cooling: 100 66 Water Heating: 113 113 SubTotal - Used to Determine Compliance: 532 483 Lights &Appliances: 656 647 Photovottaics: -0 -0 Service Charge: 240 240 Total: 1428 1369 Mandatory Requirements: Duct Insulation R-Value Check (per Section 405.2) Minimum Duct Insulation (Design must be equal or higher): 6.0 8.0 Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.400 0.340 Home Infiltration (Section 402.4.2): PASSES Duct Leakage (Section 403.2.2): PASSES This home MEETS the annual energy cost requirements of Section405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 9.2%. Name: Robert Hutchinson Signature: AZ.f Pa"'"'" ,4TIMa Organization: Burgess, Inc Date: June 26, 2014 REM/Rate -Residential Energy Analysis and Rating Software 04.4 This information does not constitute any warranty of energy cost or savings. ©1985-2013Architectural Energy Corporation, Boulder, Colorado. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT DR Horton 1220 Page 2 Design energy cost is based on the following systems: Heating: Fuel -fired air distribution,44.1 kBtuh, 92.0AFUE. Water Heating: Conventional, Gas, 0.65 EF. Cooling: Air conditioner, 11.5 kBtuh, 13.0 SEER. Window -to -Floor Area Ratio:0.11 Blower door test: Htg: 900 Clg: 900 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software v14.4 This information does not constitute any warranty of energy cost or savings. 01985-2013 Architectural Energy Corporation, Boulder, Colorado.