Loading...
HomeMy WebLinkAbout3008 Denver Dr - Disclosures/Blower Door Test - 04/25/2014A }� 5bizSer Date of Test: 4/25/2014 Customer: Journey Homes 7251 W 20th Street L-200 Greeley, CO 80634 Phone: 970-449-1612 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: BUILDING LEAKAGE TEST GS Services 2000 South College Ave Suite 308 Fort Collins, CO 80525 Test File: Journey Homes 3008 Denver DR- BD Technician: Paul Higman Project Number: Building Address: 3008 Denver Dr Fort Collins, Colorado 80525 1073 CFM50 (+/- 1.3 %) 2.75 ACH50 59.0 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 16.6 ( +/- 9.8 %) Exponent (n) = 1.065 ( +/- 0.027 ) Correlation Coefficient = 0.99959 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 60.6 CFM 0.16 ACH 2. Estimated Design Infiltration Rate: Winter: 97.7 CFM 0.25 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Summer: 64.8 CFM 0.17 ACH P a u I Digitally signed by,,'?rPaul Higman KI: Higman. 'CN = Paul Hig an C = US .' ' D e: 2014.04.28 � i0962:38-06'00' 6S?eiui S BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 4/25/2014 Test File: Journey Homes 3008 Denver DR- BD Building Information Volume 23382 Surface Area Floor Area 2445 Height 18 # of Bedrooms 3 # of Occupants Year of Construction 2014 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 G$'Ser qgSBUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 4/25/2014 Test File: Journey Homes 3008 Denver DR- BD Depressurization Test: Environmental Data Indoor Temperature (A°F) Outdoor Temperature (A*F) Altitude (ft) 69.0 J 71.0 4950.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -1.8 n/a n/a -60.1 -58.2 38.0 -55.3 -53.4 31.3 -50.2 -48.3 242.6 -45.0 -43.1 193.9 -40.0 -38.1 147.3 -35.2 -33.3 112.5 -30.1 -28.2 80.3 -25.4 -23.5 51.3 -20.0 -18.1 28.7 -2.0 n/a n/a Time Averaging Period: 10 1120 1252 -0.7 Ring A 1019 1139 -1.0 Ring A 922 1030 -0.3 Ring B 825 922 0.7 Ring B 720 805 0.2 Ring B 630 704 1.2 Ring B 533 596 2.2 Ring B 427 477 -0.6 Ring B 320 358 -1.6 Ring B Deviations from Standard RESNET Multi -Point Test - Test Parameters None - * n value outside of normally accepted limits. * n value and/or correlation coefficient limits are not officially part of the RESNET Multi -Point Test Standard. GS Se BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 4/25/2014 Test File: Journey Homes 3008 Denver DR- BD Comments House WRT Garage = - 48.1 pa