HomeMy WebLinkAbout2351 Busch Dr - Special Inspections/Engineering - 05/12/2014May 12, 2014 EARTH ENGINEERING ABInBev CONSULTANTS, LLC c/o HMS Contractors 2351 Busch Drive Fort Collins, Colorado 80524 Attn: Mr. Stanley Schaffer (Stanley. Schaffer(d,anheuser-busch.com) Mr. Dennis Wallisch (Dennis.Wallisch(a,anheuser-busch.com) Re: Construction Observation and Testing — Final Compliance Report Anheuser Busch - South Entrance Sign Installation of Two (2) Friction Piers for Entrance Sign 2351 Busch Drive Fort Collins, Colorado EEC Project No. 1134066 Mr. Schaffer and Wallisch: As requested, Earth Engineering Consultants, LLC (EEC) personnel provided construction observation and testing services for the referenced south entrance roadway improvement project on the premises of the ABInBev (Anheuser-Busch) of Fort Collins Brewery property. The services performed were provided on an essentially full-time basis and included observations of the two (2) friction pier installed on February 24, 2014 for the overhead entrance sign and testing of cast -in -place concrete for the referenced project. The results of the site observations and testing services completed by EEC personnel during the referenced period are included with this report. On February 24, 2014, EEC personnel provided observation services for the two (2) 42-inch diameter friction piers for south entrance roadway overhead sign. Those services were essentially provided on a full-time basis and included observations of friction pier diameter (42- inches), depth to installation, (approximately 15 to 15-1/2-feet below site grades), friction pier length,(total pier length with portion raised above site grades equaled 16-feet), presence of groundwater, (observed at an approximately depth of 11-feet below site grades), and displacement/dewatering methods, (driller slurry methodology and use of a concrete pump truck to displaced water at surface), reinforcing steel, and testing of cast -in -place concrete. 4396 GREENFIELD DRIVE WINDSOR, COLORADO 80550 (970) 545-3908 (FAX) 663-0282 www.earth-engineering.com �3S / 1).)5'ch PL Earth Engineering Consultants, LLC Anheuser-Busch— South Entrance Sign Final Compliance CMT/QC Report Fort Collins, Colorado EEC Project No. 1134066 May 12, 2014 Page 2 The reinforcement in general, consisted of 12 #1 0 vertical rebar with 11 #4 horizontal ties evenly spaced. The top portion consisted of two (2) rows of cross -tie reinforcement, in general accordance with detail B-B/9021 as presented on the structural drawings. The reinforcement and installation of the anchor rods were in general accordance with the. details 3/9021, A-A/9021 and B-B/9021 of the Revised Structural drawings prepared by CSD Project No. FCB-18-C-9021 Rev. 2 dated January 30/2014. During the friction pier installation phase, EEC performed observations and testing services of the cast -in -place concrete as indicated on the enclosed daily report, (Test No. 3). The concrete testing was performed in general accordance with American Concrete Institute (ACI) specifications. Field testing performed on the plastic concrete included slump, air content, unit weight, and concrete temperature. The ambient air temperature at the time of placement was also recorded. A minimum of 5 (4" x 8") concrete test cylinders were cast from representative samples for laboratory curing and compressive strength testing. Results of the field and laboratory compressive strength tests results performed are included herein. We appreciate the opportunity to be of service to you on this project. If you have any questions concerning this report, or if we can be of further service to you in any other way, please do not hesitate to contact us. Very truly yours, tants, LLC David A. Richer, P.E. Senior Project Engineer Cc: CSD Engineering — Mr. Jeff Bonnet, P.E. — ibonnetna.csd-eng.com 23S/ 6oscC7 EARTH ENGINEERING CONSULTANTS, LLC REPORT OF CAST -IN -PLACE CONCRETE TESTS GENERAL INFORMATION Placement Date: 2/24/2014 Test No.: 3 Placement Location: Pier - W Side of Street Concrete Supplier: Johnstown Ready Mix Type of Placement: Chute Ticket Number: 77809 Truck Number: 45 Mix Code: 27 Water Added on Site: None Batch Time: Sample Time: 10:15 AM Yards: 9 of 18 Required 28 Day Compressive Strength (psi): EEC Technician: KW Comments: FIELD TEST DATA TEST RESULTS SPECIFICATIONS Slump (in) ASTM C143 5' Air Content (%) ASTM C231 5.4% Unit Weight (pcf) ASTM C138 144.2 — Concrete Temperature (deg F) ASTM C1064 58 90° Max Air Temperature at Placement (deg F) 40 — Comments: COMPRESSIVE STRENGTH OF FIELD CAST TEST SPECIMENS (ASTM C39/C31) Specimen Number Date Tested Age (days) Maximum Applied Load (lbs) Cylinder Height (in) Cylinder Diameter (in) Area (in') Failure Type(psi) Compressive Strength Average Compressive Strength (psi) 3 B 03/03/14 7 63190 8 4 12.57 Shear 5030 5030 3 D 03/24/14 28 72870 8 4 12.57 Shear 5800 3 Dt 03/24/14 28 76930 8 4 12.57 Shear 6120 5970 3 02 03/24/14 28 75360 8 4 12.57 Shear 6000 Project: Anheuser-Busch - South Entrance Widening Project Number: 1134066 Report Distribution: Anheuser Busch - Stanley Schaffer: Stanley.Schaffer@anheuser-busch.com Anheuser Busch - Dennis Wallisch: Dennis.Wallisch@anheuser-busch.com Johnstown Ready Mix E EJ .� 3 5- / 3')-rcA--7 /) fe 2 4i— i E 110 IL KEY y,K A --- ------ .r R ti �«�,Y,. E A .... .............. j, A o-a it aw it.......... . II 1.0 T z- FEE -..-.r lRJ (A) a�g — — — — — — — — — — — — — — — — — — — — — — T — — — — — — — i �) II li' A ROAD SIGN AT SOUTH ENTRY ELEVATIONS & DETAILS FCB — iS — C 9021 2 2 � 8 S • � 3 I 3 GENERAL NOTES _- -.... � _ .T.'n`n'v�`en`^".er.�� ��' `ru _ :.T.� ^�.� .._.••r r.r—�.rr�•r._.�_+r N� _� ^• ++^-.+.. '^' r^ - FORT COLUNS BRENERY KEY Pi - - _ _ - .. ....ter__ } r ••^• us. F ...e._..r...-..-�.r+:_..... " e._..r._rs_..m..n..... �.. ...aws F r. I : s�Tt r' �SpN 0 Rls N�'E rr r € _. r ., ROAD SIGN AT SOUTH ENTRY qii ' ""••""`•""n"""'-•'n" -m• v C—a PLPN NOTES, AND SHEET INDEX r �i' �Lw .• a �S�^'BSI•^ — =74'o j 'd•:✓ DB SGS . FCB -'I0 -C - 9020 -.2 - - •_2•• a t B 5 � � �