HomeMy WebLinkAbout2851 Exmoor Ln - Disclosures/Blower Door Test - 05/08/2014i100 r Date of Test: 5/8/2014 Customer: Journey Homes 7251 W. 20th St L-200 Greeley, CO 80634 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: BUILDING LEAKAGE TEST GS Services 2000 S. College Ave suite 308 Fort Collins, CO 80525 Test File: Journey Homes 2851 Exmoor Lane BD Technician: Paul Higman Project Number: Building Address: 2851 Exmoor Lane Fort Collins, CO 80525 1302 CFM50 (+/- 1.2 %) 2.72 ACH50 71.6 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 176.8 (+/- 8.3 %) Exponent (n) = 0.511 ( +/- 0.023 ) Correlation Coefficient = 0.99872 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 69.7 CFM 0.15 ACH 2. Estimated Design Infiltration Rate: Winter: 118.6 CFM Summer: 78.7 CFM 0.25 ACH 0.16 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Paul Higrhansignedby Paul s D_ : CN = Paul Higman Higman 'd-us D e.2014.05.1310:32: �,0-06'00' GS'Ser *pes BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 5/8/2014 Test File: Journey Homes 2851 Exmoor Lane BD Building Information Volume 28757 Surface Area Floor Area 2901 Height 15 # of Bedrooms 3 # of Occupants Year of Construction 2014 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date' Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 ,= =� ' GS�e ���5 gUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 5/8/2014 Test File: Journey Homes 2851 Exmoor Lane BD Depressurization Test: Environmental Data Indoor Temperature(A°F) Outdoor Temperature(A°F) Altitude(ft) 69.0 72.0 4950.0 Data Points-Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -2.1 n/a n/a -60.1 -58.1 60.7 1408 1415 0.7 Ring A -55.0 -53.0 55.9 1352 1359 1.3 Ring A -50.1 -48.1 49.3 1272 1278 0.2 Ring A -45.8 -43.8 43.5 1197 1203 -1.1 Ring A -40.1 -38.1 38.4 1126 1132 -0.1 Ring A -34.8 -32.8 32.1 1032 1037 -1.2 Ring A -30.7 -28.6 28.0 965 970 -1.1 Ring A -25.2 -23.1 217.8 874 878 -0.1 Ring B -20.1 -18.1 174.0 782 786 1.5 Ring B -2.0 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test-Test Parameters None GS��@ G�S gUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 5/8/2014 Test File: Journey Homes 2851 Exmoor Lane BD Comments House WRT Garage=-46.6pa