HomeMy WebLinkAbout2808 Denver Dr - Disclosures/Final Energy - 04/26/2014Fort Collins Planning, Development & Transportation Services Community Development & Neighborhood Services Simulated Performance Alternative (SPA) Cover Sheet Submittal and Rating Type Stock Plan Permit — Projected Worst -Case Rating Lot -specific Permit - Projected Rating ❑� Completed Home —Confirmed Rating Data Required for All SPA Ratings Builder: Journey Homes Energy rater: Paul Higman Builder Model Address: Address: 2808 Denver Drive Rating Firm: GS Services Date: 4-26-14 Duct Location Inputs Location Su ply Return % Area R-Value % Area R-Value All within conditioned space 100 0 100 0 Utility Rates Energy Source Service charge I Rate Electricity 5 $/month 0.10 $/kWh Natural gas 15 $/month 0.60 $/therm Spaces considered outside the thermal boundary: Additional Information for Stock Plan Permit — Projected Worst -Case Rating "Worst -case" configuration: Foundation type(s) Options included Orientation of front elevation HAffach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report Attach REM/Rate Energy Code Inspection Checklist Additional Information for Lot -Specific Permit — Projected Rating Bttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report ttach REM/Rate Energy Code Inspection Checklist Additional Information for Completed Home — Confirmed Rating Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report (Utility rates reflected in this report must be City -approved rates on lot -specific permit application date.) ❑Attach Home Energy Rating Certificate Updated 11/09/2012 Fort Collins Energy Cost Compliance - Non Electric Heat'' 5, Property Organization Journey Homes GS Services 2808 Denver Drive 970-449-1612 Fort Collins, CO 80525 Paul Higman Weather:Ft. Collins, CO Builder 2808 Denver Drive Journey Homes Journey Homes 2808 Denver Dr - Annual Energy Cost $/yr FC 2012 As Designed Mandatory Requirements This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 1.0%. Name Paul Higman Organization GS Services Mechanical Systems Heating Fuel -fired air d Water Heating Conventional, I Cooling Air conditioner Window -to -Floor -Area Ratio. 0.12a Blower door test - Hta: 1322 Cle:' Signature Date 1 28 April 2014 Paul b, 1 AFUE ry, ■H H�i g rn an�o "/J I Higman =.Paul C-US )14.04.28 !7e='00' In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Design - Residential Energy Analysis Software v14.4.1 This information does not constitute any warranty of energy cost or savings. 0 1985-2014 Architectural Energy Corporation, Boulder, Colorado.