Loading...
HomeMy WebLinkAbout3774 Sandy Shore Ln - Applications/Single Family New - 11/23/2011BUILDING PERMITS & INSPECTIONS DIVISION P.O. Box 580 - Fort Collins, CO 80522-0580 • Phone: 221-6760 www.fcgov.com/building City of Fort Collins BUILDING PERMIT APPLICATION APPLICATION NUMBER 131 1 1 V� U APPLICATION DATE O� Job Site Address 3774 Sandy Shore Lane Unit # PROPERTY OWNER INFO: (All owner information is required — it is not optional) Phone # 970 663-9430 Last Name KEM Homes Construction, Inc First Name Middle Street Address 7352 Greenridge Rd A-6 City Windsor State CO Zip 80550 CONTRACTOR INFO: Company Name KEM Homes Construction,lnc Contractor Phone # (970) 663-9430 Lic. Holder Name William R. Krug City of Fort Collins License # B-45 Supervisor Cert # 60 Mailing Address- 7352 Greenridge Rd A-6 City Windsor State CO Zip 80550 LEGAL INFO: Subdivision/PUD Fossil Lake Swift Addition Filing # Lot # 91 CONSTRUCTION INFO: Total Building Sq Ft (not including basement) 2035 Block # Lot Sq Ft 7053 Total Garage Sq Ft 598 Residential Sq Ft 2035 Comm'I Sq Ft -- # of Stories 1 Bldg Height 21 ` # Dwelling Units 1 1st Floor Sq Ft 2035 2nd Floor Sq Ft -- Unfinished Bsmt Sq Ft 1953 Finished Bsmt Sq Ft -- # of Bedrooms 3 # of Full Baths 2 % Baths -- '/2 Baths -- # of Fireplaces 1 Air Conditioning: Yes No Energy info: (Circle appropriate choice) 1. ComCheck 2. ResCheck w/Air Sealing 3. ResCheck w/Blower Door . E-Star w/Blower Door 5. Prescriptive w/Air Sealing 6. Prescriptive w/Blower Door City of Fort Collins Stock Plan # List appropriate option #s UTILITIES INFO: Water Tap Size 3/4" Sewer Tap Size 4" Metered: Yes or No Temp. Pedestal: Yes or No Type of Heat: ® Gas ❑ Electric Electric Main Breaker Size (Residential only): ❑ 150 Amp or Less S 200 Amp ❑ Other Value of Construction (including labor, material & profit) $ 229,312.40 Description of Work: New single family residence with a 2—car garage and a full basement. Contact Name & Phone # of JOBSITE SUPERVISOR: Bill Gurski, 566-3208 Subcontractor Info: Electrical Rossi Electric Mechanical NCA Plumbing Colorado Plumbing VdLhde le.V r" Framer r> nstrrrr:tZon oofing Behrends Roofing Concrete Sipes Concrete Other Applicant: I hereby acknowledge that I have read this application and state that the above information is correct and agree to comply with all requirements contained herein and City of ortollins ordi a state laws regulating building construction. Applicant Signature - Print Name William E. Gurski Phone ('970) 663-9430 Distribution: White - Office Yellow - Applicant Pink - WWW/Stormwater THIS APPLICATION EXPIRES 90 DAYS FROM APPLICATION DATE Community Planning and Environmental Services Fort Collins Neighborhood & Building Services can �s cQi:�s 281 N. College Ave., P.O. Box 580;Fort Collins, CO 80522; 970-221-6760 2005 FORT COLLINS RESIDENTIAL ENERGY CODE COMPLIANCE FORM Permit Number: updated 9-19-06 Address: 77zl 6wJ-Jv 5X6peZa�e- DIRECTIONS: Place a check next to Presc ptive, UA, or SPA indicating the path chosen. Next, circle the method within that path you intend to follow. If choosing prescriptive or UA, the applicant must also choose between an Air sealina checklist nr Rinwar nnnr roof (A)PRESCRIPTIVE compliance for house with natural gas heating and wood framing, N1111.1 Insulation R-value Standard HVAC equipment, (80%AFUE) High efficiency HVAC equipment (90%AFUE Method 1 2x6 Walls Method 2 2x4 Walls Method 3 2x6 Walls Method 4 2x4 Walls Exterior walls above grade frame 18 _ 38 19 13/10 30 15 3 38 19 13/10 30 18 - 38 19 - 19 15 - 38 19 13110 19 Exterior insulated sheathing Ceilin /attic Crawls ace walls Basement walls. frame/continous Floor over un-cond space A N+IUM cane; Air aeanng L;necKust Blower Door Test (B)TOTAL UA ALTERNATIVE, (REScheck) SECTION N1111.5 REScheck must show a passing score of 10% better than code minimum. Submit calculations demonstrating equivalency to one of the prescriptive methods above. The rating must be submitted at time of application and must include Address of residence; Name of individual completing the rating form; Name & version of software tool. Air Sealing Checklist or Blower Door Test is required. Circle one: Air Sealing Checklist Blower Door Test C)SIMULATED PERFORMANCE ALTERNATIVE, SECTION N1113 Current accredited programs: E-star of Colorado or Energvloaic HERS accredited energy rating system. Must submit HERS index of 94 maximum. A preliminary rating must be submitted at time of application and must include Address of residence; Name of individual completing the rating/compliance form; Name & version of software tool. Final ratinq requires a blower door test. �► V IJ- men, s Community Planning and Environmental Services Building and Zoning Department . Building Permit Application Submittal Requirements for New Residential Construction - 2003 IRC City of Fort Collins Revised 9-22-2005 The items listed below must be included in all new residential submittal requests for building permit. Please initial in front of the item indicating that it is included in the submittal. Only complete submittals will be reviewed. There will be no exceptions. Initial Required Item Building Permit Application — Three-part form to be completed by applicant. Plan Check Fee - (See www.fcgov.com or obtain Fee Schedule at B & Z counter) Site Plans - Two copies of the architectural site plan, drawn to scale on 8 1/2"xll" sheet showing the location of the building relative to property lines and other structures on the lot. Architectural Drawings - Two copies of architectural drawings showing all floor plans, elevations, stair section, building section, and wall section detailing all construction components used. Drawings must be drawn Ito scale such as 1/4"= V-0". Structural Drawings (floor framing & roof framing) — Two copies of structural documents bearing an original seal and signature of an architect or engineer registered in the State of Colorado. Structural drawingsi, shall inlcude all beams, floor system, roof system, spans, posts, columns, hangers and connections, and locate and identify all point loads. Plans shall verify that the design meets the following criteria: Wind load=100 MPH exposure B, 30-LB roof/snow live load and 15-LB dead load. Wall Brace Design — Two copies of all "Brace Wall" locations and method of construction. If the house does not meet the prescriptive brace "requirements of 2003 IRC section R602, engineered design bearing an original seal and signature of an architect or engineer registered in the State of Colorado is required. Engineered Foundation - Two copies of foundation documents bearing an original seal and signature of an architect or engineer registered in the State of Colorado. The design requirements shall be for a 30" frost dept, seismic zone (1) and 30-LB snow load. Identify wet or damp-proof requirements. Identify and size subsurface drainage system. Energy Code - Submit the 2005 Fort Collins Energy Code Compliance Form. If SPA method is selected, preliminary rating must be submitted also. Hvac sizing & load calculations - Code section M1401.3 requires the hvac system be designed by lic mechanical Contractor/Engineer based on loads calculated from ACCA manual J. Duct sizing must be included designed per ACCA manual D. Other - Include legal, construction, utility, value of construction,. description of work and subcontractor information. All applications must be signed by the applicant and must include a daytime phone number. ***Add'/ information. (required by Lanmer CountyAssessor). Ifnot filled out correctly, application will not be accepted, There will be no exceptions Sq ft on first floor 203.E Sq ft on 2"d floorJVl /i Sq ft in garage A/C - yes or no # of fireplaces I #of full baths a #of 3/4 baths N Ili #of half baths XIIA Applicant Name K E Yn ai Cn u1, ak Telephone Number 63 �} L/3 O Job Site Address 3? 7 `� ` 4,,4 S k al c Le0 1 1 1 281 North College Avenue - P.O. Box 580 - Fort Collins, CO 80522-0580 - (970) 221-6760 - FAX (970) 224-6134