HomeMy WebLinkAbout221 Jefferson St - Special Inspections/Engineering - 12/19/2011Jack P. Renfroe, P.E. CIVIL ENGINEER 6180 W.101h Street Greeley, Colorado 80634 (970) 352-0876 December 14, 2011 City of Ft. Collins 281 North College Ave Fort Collins, Colorado 80524 DEC fl 9 2011 H RE: Trench wall inspection for — 221-227 Jefferson Street, Jefferson Street Renovations, Ft Collins Colorado Permit Number: B 11-06475 Gentleman: I have inspected the trench wall for Hammersmith Construction located at 221-227 Jefferson Street, in Ft Collins Colorado. Structural engineer design was TD Structural Engineering, P.E. No: 38181 The piers were inspected on December 12, 2011, 8 piers at 18" x 36"all were installed with (4) #4 (grade 60) rebar vertical with # 3 ties per engineered pier sizes. I inspected the trench wall on December 12, 2011 (2) # 4 (grade 60) rebar was place top and bottom in wall with # 3 ties at 24" in wall. #4 (grade 60) rebar dowells were placed @ 32" at top of walla If you hav estioi GK P• RF Re ec6�srF��� O please call me at (970) 352-0876. 3